The prevalence of oral mucosal lesions in Malaysia was determined by examining a representative sample of 11,707 subjects aged 25 years and above throughout the 14 states over a period of 5 months during 1993/1994. A two-stage stratified random sampling was undertaken. A predetermined number of enumeration blocks, the smallest population unit in the census publication, was selected from each state. With the selected enumeration block, a systematic sample of living quarters was chosen with a random start. The survey instrument included a questionnaire on sociodemographic characteristics and a clinical examination. The clinical examination was carried out by 16 specially trained dental public health officers and the diagnosis calibrated with a final concordance rate of 92%. The age in the sample ranged from 25 to 115 years with a mean of 44.5+/-14.0. The sample comprised 40.2% males and 59.8% females; 55.8% were Malays, 29.4% Chinese, 10.0% Indians and 1.2% other ethnic groups. Oral mucosal lesions were detected in 1131 (9.7%) subjects, 5 (0.04%) had oral cancer, 165 (1.4%) had lesions or conditions that may be precancerous (leukoplakia, erythroplakia, submucous fibrosis and lichen planus) and 187 (1.6%) had betel chewer's mucosa. The prevalence of oral precancer was highest amongst Indians (4.0%) and other Bumiputras (the indigenous people of Sabah and Sarawak) (2.5%) while the lowest prevalence was amongst the Chinese (0.5%).
An extremely sensitive and simple gas chromatography with mass spectrometry method was developed and completely validated for the analysis of five process-related impurities, viz., 4-hydroxy-l-phenylglycine, 4-hydroxyphenylacetonitrile, 4-hydroxyphenylacetic acid, methyl-4-hydroxyphenylacetate, and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl)amino]propoxy}phenyl]acetonitrile, in atenolol. The separation of impurities was accomplished on a BPX-5 column with dimensions of 50 m × 0.25 mm i.d. and 0.25 μm film thickness. The method validation was performed following International Conference on Harmonisation guidelines in which the method was capable to quantitate 4-hydroxy-l-phenylglycine, 4-hydroxyphenylacetonitrile, and 4-hydroxyphenylacetic acid at 0.3 ppm, and methyl-4-hydroxyphenylacetate and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl)amino]propoxy}phenyl]acetonitrile at 0.35 ppm with respect to 10 mg/mL of atenolol. The method was linear over the concentration range of 0.3-10 ppm for 4-hydroxy-l-phenylglycine, 4-hydroxyphenylacetonitrile, and 4-hydroxyphenylacetic acid, and 0.35-10 ppm for methyl-4-hydroxyphenylacetate and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl)amino]propoxy}phenyl]acetonitrile. The correlation coefficient in each case was found ≥0.998. The repeatability and recovery values were acceptable, and found between 89.38% and 105.60% for all five impurities under optimized operating conditions. The method developed here is simple, selective, and sensitive with apparently better resolution than the reported methods. Hence, the method is a straightforward and good quality control tool for the quantitation of selected impurities at trace concentrations in atenolol.
In this study, the adsorption behavior of azo dye Acid Orange 7 (AO7) from aqueous solution onto macrocomposite (MC) was investigated under various experimental conditions. The adsorbent, MC, which consists of a mixture of zeolite and activated carbon, was found to be effective in removing AO7. The MC were characterized by scanning electron microscopy (SEM), energy dispersive X-ray, point of zero charge, and Brunauer-Emmett-Teller surface area analysis. A series of experiments were performed via batch adsorption technique to examine the effect of the process variables, namely, contact time, initial dye concentration, and solution pH. The dye equilibrium adsorption was investigated, and the equilibrium data were fitted to Langmuir, Freundlich, and Tempkin isotherm models. The Langmuir isotherm model fits the equilibrium data better than the Freundlich isotherm model. For the kinetic study, pseudo-first-order, pseudo-second-order, and intraparticle diffusion model were used to fit the experimental data. The adsorption kinetic was found to be well described by the pseudo-second-order model. Thermodynamic analysis indicated that the adsorption process is a spontaneous and endothermic process. The SEM, Fourier transform infrared spectroscopy, ultraviolet-visible spectral and high performance liquid chromatography analysis were carried out before and after the adsorption process. For the phytotoxicity test, treated AO7 was found to be less toxic. Thus, the study indicated that MC has good potential use as an adsorbent for the removal of azo dye from aqueous solution.
Reactive dyes account for one of the major sources of dye wastes in textile effluent. In this study, decolorization of the monoazo dye, Acid Orange 7 (AO7) by the Enterococcus faecalis strain ZL that isolated from a palm oil mill effluent treatment plant has been investigated. Decolorization efficiency of azo dye is greatly affected by the types of nutrients and the size of inoculum used. In this work, one-factor-at-a-time (method and response surface methodology (RSM) was applied to optimize these operational factors and also to study the combined interaction between them. Analysis of AO7 decolorization was done using Fourier transform infrared (FTIR) spectroscopy, desorption study, UV-Vis spectral analysis, field emission scanning electron microscopy (FESEM), and high performance liquid chromatography (HPLC). The optimum condition via RSM for the color removal of AO7 was found to be as follows: yeast extract, 0.1% w/v, glycerol concentration of 0.1% v/v, and inoculum density of 2.5% v/v at initial dye concentration of 100 mg/L at 37 °C. Decolorization efficiency of 98% was achieved in only 5 h. The kinetic of AO7 decolorization was found to be first order with respect to dye concentration with a k value of 0.87/h. FTIR, desorption study, UV-Vis spectral analysis, FESEM, and HPLC findings indicated that the decolorization of AO7 was mainly due to the biosorption as well as biodegradation of the bacterial cells. In addition, HPLC analyses also showed the formation of sulfanilic acid as a possible degradation product of AO7 under facultative anaerobic condition. This study explored the ability of E. faecalis strain ZL in decolorizing AO7 by biosorption as well as biodegradation process.
The capabilities and performances of a quadrupole ion trap under damping force based on collisional cooling is of particular importance in high-resolution mass spectrometry and should be analyzed by Mathieu's differential solutions. These solutions describe the stability and instability of the ion's trajectories confined in quadrupole devices. One of the methods for solving Mathieu's differential equation is a two-point one block method. In this case, Mathieu's stability diagram, trapping parameters a(z) and q(z) and the secular frequency of the ion motion w(z), can be derived in a precise manner. The two-point one block method (TPOBM) of Adams Moulton type is presented to study these parameters with and without the effect of damping force and compared to the 5th-order Runge-Kutta method (RKM5). The simulated results show that the TPOBM is more accurate and 10 times faster than the RKM5. The physical properties of the confined ions in the r and z axes are illustrated and the fractional mass resolutions m/Δm of the confined ions in the first stability region were analyzed by the RKM5 and the TPOBM.
This study presents a data registration method for craniofacial spatial data of different modalities. The data consists of three dimensional (3D) vector and raster data models. The data is stored in object relational database. The data capture devices are Laser scanner, CT (Computed Tomography) scan and CR (Close Range) Photogrammetry. The objective of the registration is to transform the data from various coordinate systems into a single 3-D Cartesian coordinate system. The standard error of the registration obtained from multimodal imaging devices using 3D affine transformation is in the ranged of 1-2 mm. This study is a step forward for storing the spatial craniofacial data in one reference system in database.