Displaying publications 21 - 29 of 29 in total

Abstract:
Sort:
  1. Darlis N, Osman K, Padzillah MH, Dillon J, Md Khudzari AZ
    Artif Organs, 2018 May;42(5):493-499.
    PMID: 29280161 DOI: 10.1111/aor.13021
    Physiologically, blood ejected from the left ventricle in systole exhibited spiral flow characteristics. This spiral flow has been proven to have several advantages such as lateral reduction of directed forces and thrombus formation, while it also appears to be clinically beneficial in suppressing neurological complications. In order to deliver spiral flow characteristics during cardiopulmonary bypass operation, several modifications have been made on an aortic cannula either at the internal or at the outflow tip; these modifications have proven to yield better hemodynamic performances compared to standard cannula. However, there is no modification done at the inlet part of the aortic cannula for inducing spiral flow so far. This study was carried out by attaching a spiral inducer at the inlet of an aortic cannula. Then, the hemodynamic performances of the new cannula were compared with the standard straight tip end-hole cannula. This is achieved by modeling the cannula and attaching the cannula at a patient-specific aorta model. Numerical approach was utilized to evaluate the hemodynamic performance, and a water jet impact experiment was used to demonstrate the jet force generated by the cannula. The new spiral flow aortic cannula has shown some improvements by reducing approximately 21% of impinging velocity near to the aortic wall, and more than 58% reduction on total force generated as compared to standard cannula.
    Matched MeSH terms: Blood Flow Velocity
  2. Koh KH
    Singapore Med J, 2006 Sep;47(9):785-95.
    PMID: 16924361
    Infusing the replacement solution before the filter (pre-dilution) and regular flushing have not been accounted for in conventional mathematical equations. Their effects on various continuous renal replacement therapy (CRRT) parameters, such as ultrafiltration fraction and urea clearance, have not been well studied. We incorporated these parameters into mathematical equations to help in understanding and prescribing CRRT.
    Matched MeSH terms: Blood Flow Velocity
  3. Abas A, Mokhtar NH, Ishak MH, Abdullah MZ, Ho Tian A
    Comput Math Methods Med, 2016;2016:6143126.
    PMID: 27239221 DOI: 10.1155/2016/6143126
    This paper simulates and predicts the laminar flow inside the 3D aneurysm geometry, since the hemodynamic situation in the blood vessels is difficult to determine and visualize using standard imaging techniques, for example, magnetic resonance imaging (MRI). Three different types of Lattice Boltzmann (LB) models are computed, namely, single relaxation time (SRT), multiple relaxation time (MRT), and regularized BGK models. The results obtained using these different versions of the LB-based code will then be validated with ANSYS FLUENT, a commercially available finite volume- (FV-) based CFD solver. The simulated flow profiles that include velocity, pressure, and wall shear stress (WSS) are then compared between the two solvers. The predicted outcomes show that all the LB models are comparable and in good agreement with the FVM solver for complex blood flow simulation. The findings also show minor differences in their WSS profiles. The performance of the parallel implementation for each solver is also included and discussed in this paper. In terms of parallelization, it was shown that LBM-based code performed better in terms of the computation time required.
    Matched MeSH terms: Blood Flow Velocity
  4. Amudha K, Choy AM, Mustafa MR, Lang CC
    Cardiovasc Ther, 2008;26(4):253-61.
    PMID: 19035876 DOI: 10.1111/j.1755-5922.2008.00064.x
    Endothelial function is impaired in healthy subjects at risk of type 2 diabetes mellitus (DM). We investigated whether endothelial dysfunction can be normalized by statin therapy in this potentially predisposed population. Flow-mediated dilation (FMD) was measured in 56 first-degree relatives (FDRs) (normotensive, normal glucose tolerance) and 20 age-, sex-, and BMI-matched controls with no family history of DM. Other measurements included insulin resistance index using the homeostasis model of insulin resistance (HOMA(IR)), plasma lipids, and markers of inflammation. The FDRs were then randomized and treated with atorvastatin (80 mg) or placebo daily in a 4-week double-blind, placebo-controlled trial. The FDRs had significantly impaired FMD (4.4 +/- 8.1% vs. 13.0 +/- 4.2%; P < 0.001), higher HOMA(IR) (1.72 +/- 1.45 vs. 1.25 +/- 0.43; P = 0.002), and elevated levels of plasma markers of inflammation-highly sensitive C-reactive protein (hsCRP) (2.6 +/- 3.8 mg/L vs. 0.7 +/- 1.0 mg/L; P = 0.06), interleukin (IL)-6 (0.07 +/- 0.13 ng/mL vs. 0.03 +/- 0.01 ng/mL; P < 0.001), and soluble intercellular adhesion molecule (sICAM) (267.7 +/- 30.7 ng/mL vs. 238.2 +/- 20.4 ng/mL; P < 0.001). FMD improved in the atorvastatin-treated subjects when compared with the placebo-treated subjects (atorvastatin, from 3.7 +/- 8.5% to 9.8 +/- 7.3%; placebo, from 3.9 +/- 5.6% to 4.7 +/- 4.2%; P = 0.001). There were also reductions in the levels of IL-6 (0.08 +/- 0.02 ng/mL vs. 0.04 +/- 0.01 ng/mL; P < 0.001) and hsCRP (3.0 +/- 3.9 mg/L vs. 1.0 +/- 1.3 mg/L; P = 0.006). Our study suggests that treatment with atorvastatin may improve endothelial function and decrease levels of inflammatory markers in FDRs of type 2 DM patients.
    Matched MeSH terms: Blood Flow Velocity/drug effects
  5. Tan MP, Chadwick TJ, Kerr SR, Parry SW
    J Am Heart Assoc, 2014 Jun;3(3):e000514.
    PMID: 24947997 DOI: 10.1161/JAHA.113.000514
    Carotid sinus hypersensitivity (CSH) is associated with syncope, unexplained falls, and drop attacks in older people but occurs asymptomatically in 35% of community-dwelling elders. We hypothesized that impaired cerebral autoregulation is associated with the conversion of asymptomatic CSH to symptomatic CSH. We therefore conducted a case-control study evaluating individuals with CSH with and without the symptoms of syncope or unexplained falls, as well as non-CSH controls, to determine whether the blood pressure and heart rate changes associated with CSH are associated with symptoms only when cerebral autoregulation is altered.
    Matched MeSH terms: Blood Flow Velocity
  6. Govindaraju K, Badruddin IA, Viswanathan GN, Ramesh SV, Badarudin A
    Phys Med, 2013 May;29(3):225-32.
    PMID: 22704601 DOI: 10.1016/j.ejmp.2012.03.008
    Coronary Artery Disease (CAD) is responsible for most of the deaths in patients with cardiovascular diseases. Diagnostic coronary angiography analysis offers an anatomical knowledge of the severity of the stenosis. The functional or physiological significance is more valuable than the anatomical significance of CAD. Clinicians assess the functional severity of the stenosis by resorting to an invasive measurement of the pressure drop and flow. Hemodynamic parameters, such as pressure wire assessment fractional flow reserve (FFR) or Doppler wire assessment coronary flow reserve (CFR) are well-proven techniques to evaluate the physiological significance of the coronary artery stenosis in the cardiac catheterization laboratory. Between the two techniques mentioned above, the FFR is seen as a very useful index. The presence of guide wire reduces the coronary flow which causes the underestimation of pressure drop across the stenosis which leads to dilemma for the clinicians in the assessment of moderate stenosis. In such condition, the fundamental fluid mechanics is useful in the development of new functional severity parameters such as pressure drop coefficient and lesion flow coefficient. Since the flow takes place in a narrowed artery, the blood behaves as a non-Newtonian fluid. Computational fluid dynamics (CFD) allows a complete coronary flow simulation to study the relationship between the pressure and flow. This paper aims at explaining (i) diagnostic modalities for the evaluation of the CAD and valuable insights regarding FFR in the evaluation of the functional severity of the CAD (ii) the role of fluid dynamics in measuring the severity of CAD.
    Matched MeSH terms: Blood Flow Velocity
  7. Chan BT, Lim E, Chee KH, Abu Osman NA
    Comput Biol Med, 2013 May;43(4):377-85.
    PMID: 23428371 DOI: 10.1016/j.compbiomed.2013.01.013
    The heart is a sophisticated functional organ that plays a crucial role in the blood circulatory system. Hemodynamics within the heart chamber can be indicative of exert cardiac health. Due to the limitations of current cardiac imaging modalities, computational fluid dynamics (CFD) have been widely used for the purposes of cardiac function assessment and heart disease diagnosis, as they provide detailed insights into the cardiac flow field. An understanding of ventricular hemodynamics and pathological severities can be gained through studies that employ the CFD method. In this research the hemodynamics of two common myocardial diseases, dilated cardiomyopathy (DCM) and myocardial infarction (MI) were investigated, during both the filling phase and the whole cardiac cycle, through a prescribed geometry and fluid structure interaction (FSI) approach. The results of the research indicated that early stage disease identification and the improvement of cardiac assisting devices and therapeutic procedures can be facilitated through the use of the CFD method.
    Matched MeSH terms: Blood Flow Velocity
  8. Rasyada AR, Sha'ban M, Azhim A
    Cardiovasc J Afr, 2018;29(3):146-149.
    PMID: 30067273 DOI: 10.5830/CVJA-2018-001
    INTRODUCTION: The aim of this study was to evaluate the impact of different visceral fat (VF) and blood pressure (BP) levels on changes in blood flow velocity (BFV) among non-obese subjects, using a cross-sectional study approach.

    METHODS: A total of 110 putatively healthy and non-obese subjects were divided into three groups according to their level of VF and BP. Common carotid artery BFV was measured using a developed portable Doppler ultrasound measurement system.

    RESULTS: The most pronounced peak systolic velocity (S1) was lower (p < 0.05) in the hypertensive group and the peak diastolic velocity (D) was significantly lower in the pre-hypertensive group than in the normotensive group. There were differences in velocity reflection and resistive indices between the hypertensive and other two BP groups. The higher VF group had significantly lower S1 and D velocities and resistive and vascular elasticity indices. By contrast, the velocity reflection index was larger in the higher VF group.

    CONCLUSIONS: We confirmed that there were significant differences in the BFV among non-obese subjects who differed in level of VF and BP. This study confirms that a putatively increasing VF and BP level is associated with the development of hypertension.

    Matched MeSH terms: Blood Flow Velocity
  9. Basri AA, Zuber M, Basri EI, Zakaria MS, Aziz AFA, Tamagawa M, et al.
    Comput Math Methods Med, 2020;2020:9163085.
    PMID: 32454886 DOI: 10.1155/2020/9163085
    This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL condition, which involves both fluid and structural responses in coupling interaction. Hence, further FSI simulation with the two-way coupling method is implemented to investigate the effects of hemodynamics blood flow along the patient-specific aorta model subjected to the interrelationship between PVL and the different valve openings using the established FSI software ANSYS 16.1. A 3D patient-specific aorta model is constructed using MIMICS software. The TAVI valve identical to Edward SAPIEN XT 26 (Edwards Lifesciences, Irvine, California), at different Geometrical Orifice Areas (GOAs), is implanted into the patient's aortic annulus. The leaflet opening of the TAVI valve is drawn according to severity of GOA opening represented in terms of 100%, 80%, 60%, and 40% opening, respectively. The result proved that the smallest percentage of GOA opening produced the highest possibility of PVL, increased the recirculatory flow proximally to the inner wall of the ascending aorta, and produced lower backflow velocity streamlines through the side area of PVL region. Overall, 40% GOA produced 89.17% increment of maximum velocity magnitude, 19.97% of pressure drop, 65.70% of maximum WSS magnitude, and a decrement of 33.62% total displacement magnitude with respect to the 100% GOA.
    Matched MeSH terms: Blood Flow Velocity
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links