Displaying publications 21 - 27 of 27 in total

Abstract:
Sort:
  1. Ab-Ghani Z, Ngo H, McIntyre J
    Aust Dent J, 2007 Dec;52(4):276-81.
    PMID: 18265682
    BACKGROUND: There have been cononcerns about the dissolution of conventional glass ionomer cement (GIC) and its possible degradation when exposed to an acidic environment over time. The objective of this study was to investigate the effects of exposure of Fuji IX Fast to the simulated acidic aspects of the oral environment in terms of any change in the elemental composition of strontium (Sr), phosphorus (P), calcium (Ca) and fluorine (F) which resulted at the surface of this material.

    METHODS: Sixty-five cylindrical block of Fuji IX Fast were prepared using split moulds. The demineralizing solution was an acetate buffered demineralizing solution at pH 403. The remineralizing solution was a buffered solution containing 1.5 mM Ca, 0.9 mM P and 10 ppm F at pH 7. The blocks of Fuji IX Fast were subjected either to two-day alternating cycles of remineralization and demineralization for up to 24 days (test); 6 two-day cycles of demineralizing or remineralizing solution separately, or deionized distilled water alone (controls) or were left untreated (base line control). Mineral profiles of Ca, P, Sr and F within 100 microm of the material surface were assessed following 8, 16 and 24 days of treatment (test); 4, 8 or 12 days (controls) or for baseline control samples, using electron probe microanalysis (EPMA).

    RESULTS: There were significant changes in mineral profile in the test specimens in terms of Sr and Ca concentrations. A molecule for molecule exchange of these elements resulted between GIC and eluant solutions. Fluoride loss from the GIC occurredto the level comparable with uptake levels recorded in eluant solutions from previous studies. The ionic exchanges appeared to be the result of dissolution followed by an equilibrium-driven diffusion. These exchanges were superficial though substantial.

    CONCLUSIONS: Simulated exposure of Fuji IX to the oral environment resulted in an exchange of Ca from the bathing solutions into Fuji IX to replace any Sr which was lost to the GIC. Fluorine loss from the GIC followed previously described patterns. The possible clinical significance of this exchange was discussed.

    Matched MeSH terms: Calcium/analysis
  2. Ariffin AF, Yusof N, Mohd S, Rahman SA, Ramalingam S, Mansor A, et al.
    Cell Tissue Bank, 2019 Dec;20(4):527-534.
    PMID: 31456097 DOI: 10.1007/s10561-019-09785-4
    Calcium contents of demineralised human cortical bone determined by titrimetric assay and atomic absorption spectrophotometry technique were verified by comparing to neutron activation analysis which has high recovery of more than 90%. Conversion factors determined from the comparison is necessary to correct the calcium content for each technique. Femurs from cadaveric donors were cut into cortical rings and demineralised in 0.5 M hydrochloric acid for varying immersion times. Initial calcium content in the cortical bone measured by titration was 4.57%, only 21% of the measurement by neutron activation analysis; while measured by atomic absorption spectrophotometer was 13.4%, only 61% of neutron activation analysis. By comparing more readings with the measurements by neutron activation analysis with 93% recovery, a conversion factor of 4.83 was verified and applied for the readings by titration and 1.45 for atomic absorption spectrophotometer in calculating the correct calcium contents. The residual calcium content started to reduce after the cortical bone was demineralised in hydrochloric acid for 8 h and reduced to 13% after 24 h. Using the linear relationship, the residual calcium content could be reduced to less than 8% after immersion in hydrochloric acid for 40 h. Atomic absorption spectrophotometry technique is the method of choice for calcium content determination as it is more reliable compared to titrimetric assay.
    Matched MeSH terms: Calcium/analysis*
  3. Sarimin AS, Ghaffar MA, Mohamed CA
    Pak J Biol Sci, 2009 Feb 01;12(3):231-8.
    PMID: 19579951
    A study on elemental composition in the otolith of giant mudskipper, Periophthalmodon schlosseri, was done from June to October 2003. Specimens were obtained from the mangrove areas of Kuala Selangor, Sepang and Melaka in the west coast of Peninsular Malaysia. A total of 70 sagitta otoliths were analyzed to detect variation of Sr, Ba and Mg, replacing the natural chemical composition of the otolith, which is the calcium carbonate (CaCO3). The average ratio of Sr:Ca was 0.11 x 10(-4), Ba:Ca was 5.7 x 10(-3) and Mg:Ca was 0.2 x 10(-3). Strong correlation (R > 0.8) between fish body size and otolith weight ofmudskipper (p < 0.01) also found during this study.
    Matched MeSH terms: Calcium/analysis*
  4. Bakhsh A, Mustapha NM, Mohamed S
    Nutrition, 2013 Apr;29(4):667-72.
    PMID: 23290096 DOI: 10.1016/j.nut.2012.09.005
    Postmenopausal estrogen deficiency often causes bone density loss and osteoporosis. This study evaluated the effects of an oral administration of oil palm leaf extract (OPL) on bone calcium content and structure, bone density, ash weights, and serum total alkaline phosphatase (T-ALP) of estrogen-deficient ovariectomized (OVX) rats.
    Matched MeSH terms: Calcium/analysis
  5. Isa NM, Aris AZ, Sulaiman WN
    Sci Total Environ, 2012 Nov 1;438:414-25.
    PMID: 23022725 DOI: 10.1016/j.scitotenv.2012.08.069
    Small islands are susceptible to anthropogenic and natural activities, especially in respect of their freshwater supply. The freshwater supply in small islands may be threatened by the encroachment of seawater into freshwater aquifers, usually caused by over pumping. This study focused on the hydrochemistry of the Kapas Island aquifer, which controls the groundwater composition. Groundwater samples were taken from six constructed boreholes for the analysis and measurement of its in-situ and major ions. The experimental results show a positive and significant correlation between Na-Cl (r=0.907; p<0.01), which can be defined as the effect of salinization. The mechanisms involved in groundwater chemistry changes were ion exchange and mineralization. These processes can be demonstrated using Piper's diagram in which the water type has shifted into a Na-HCO(3) water type from a Ca-HCO(3) water type. Saturation indices have been calculated in order to determine the saturation condition related to dissolution or the precipitation state of the aquifer bedrock. About 76% of collected data (n=108) were found to be in the dissolution process of carbonate minerals. Moreover, the correlation between total CEC and Ca shows a positive and strong relationship (r=0.995; p<0.01). This indicates that the major mineral component in Kapas Island is Ca ion, which contributes to the groundwater chemical composition. The output of this research explains the chemical mechanism attributed to the groundwater condition of the Kapas Island aquifer.
    Matched MeSH terms: Calcium/analysis
  6. Baradaran H, Ng CR, Gupta A, Noor NM, Al-Dasuqi KW, Mtui EE, et al.
    Int Angiol, 2017 Oct;36(5):445-461.
    PMID: 28541017 DOI: 10.23736/S0392-9590.17.03811-1
    BACKGROUND: The extent of calcium volume in the carotid arteries of contrast-based computer tomography (CT) is a valuable indicator of stroke risk. This study presents an automated, simple and fast calcium volume computation system. Since the high contrast agent can sometimes obscure the presence of calcium in the CT slices, it is therefore necessary to identify these slices before the corrected volume can be estimated.

    METHODS: The system typically consists of segmenting the calcium region from the CT scan into slices based on Hounsfield Unit-based threshold, and subsequently computing the summation of the calcium areas in each slice. However, when the carotid volume has intermittently higher concentration of contrast agent, a dependable approach is adapted to correct the calcium region using the neighboring slices, thereby estimating the correct volume. Furthermore, mitigation is provided following the regulatory constraints by changing the system to semi-automated criteria as a fall back solution. We evaluate the automated and semi-automated techniques using completely manual calcium volumes computed based on the manual tracings by the neuroradiologist.

    RESULTS: A total of 64 patients with calcified plaque in the internal carotid artery were analyzed. Using the above algorithm, our automated and semi-automated system yields correlation coefficients (CC) of 0.89 and 0.96 against first manual readings and 0.90 and 0.96 against second manual readings, respectively. Using the t-test, there was no significant difference between the automated and semi-automated methods against manual. The intra-observer reliability was excellent with CC 0.98.

    CONCLUSIONS: Compared to automated method, the semi-automated method for calcium volume is acceptable and closer to manual strategy for calcium volume. Further work evaluating and confirming the performance of our semi-automated protocol is now warranted.

    Matched MeSH terms: Calcium/analysis*
  7. Rahim ZH, Yaacob HB
    J Nihon Univ Sch Dent, 1991 Dec;33(4):205-10.
    PMID: 1787416
    The concentrations of calcium, phosphate, protein and nitrite in whole unstimulated saliva, and the salivary flow rate under fasting conditions (saliva collected at least after 6 h without food and water) were compared with those under control conditions (saliva collected within 30 min to 1 h after food). The flow rate of fasting saliva was half that of control (0.098 ml/min vs 0.208 ml/min) and no significant differences in the flow rate were observed between sexes. The concentration of nitrite under fasting conditions was 50% higher than that in control saliva (p less than 0.05). The protein concentration was decreased, but not significantly, under fasting conditions. The composition of fasting saliva with regard to calcium and phosphate concentrations was comparable to that of the control. No significant variations in these components between sexes were observed under either condition.
    Matched MeSH terms: Calcium/analysis
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links