Displaying publications 21 - 27 of 27 in total

Abstract:
Sort:
  1. Alwi M, Budi RR, Mood MC, Leong MC, Samion H
    Cardiol Young, 2013 Apr;23(2):197-202.
    PMID: 22640635 DOI: 10.1017/S1047951112000595
    Objective: To determine the feasibility and safety of the Conquest Pro wire as an alternative to radiofrequency wire for perforation of atretic pulmonary valve and subsequent balloon dilatation and patent ductus arteriosus stenting in patients with pulmonary atresia with intact ventricular septum.
    Background: Radiofrequency valvotomy and balloon dilatation has become the standard of care for pulmonary atresia with intact ventricular septum in many institutions today.
    Methods: We report eight consecutive patients in whom we used the Conquest Pro coronary guidewire, a stiff wire normally reserved for revascularisation of coronary lesions with chronic total occlusion, for perforation of atretic pulmonary valve and subsequent balloon dilatation, and stenting of the patent ductus arteriosus.
    Results: Perforation of atretic pulmonary valve was successful in seven out of eight cases. Radiofrequency valvotomy was employed after failure of perforation by the Conquest Pro wire in one case where the right ventricular outflow tract was broad based and tapered towards the pulmonary valve, and was heavily trabeculated. Failure of the Conquest Pro wire to perforate the pulmonary valve plate was mainly attributed by the failure to engage the wire at the correct position.
    Conclusion: The Conquest Pro wire for perforation and subsequent interventions in the more straightforward cases of pulmonary atresia with intact ventricular septum is effective and safe, simplifying the entire procedure. However, the radiofrequency generator and wires remain essential tools in the paediatric interventional catheter laboratory.
    Matched MeSH terms: Cardiac Catheterization/methods
  2. Wong AR, Suhaimi H, Ridzuan MA, Rizal MM, Saedah A
    Singapore Med J, 2009 Oct;50(10):e358-61.
    PMID: 19907875
    We present two infants whose endovascular lines were accidentally cut or fractured, and had to be retrieved via transcatheter means in the cardiac catheterisation laboratory. The first case was a two-month-old infant with transposition of the great arteries, requiring an emergency balloon atrial septostomy. An indwelling vascular catheter that was placed in the right femoral vein was accidentally cut and had migrated into the inferior vena cava, before being retrieved. The second case was a one-week-old neonate who presented with pneumonia at birth, and had a long intravenous catheter placed in the left saphenous vein, which became fractured, and subsequently migrated into the heart. This case presented as a pulmonary embolus with haemodynamic instability, as the catheter had partially obstructed the right ventricular outflow tract. This was later retrieved via transcatheter means.
    Matched MeSH terms: Cardiac Catheterization/methods*
  3. Ahrens I, Averkov O, Zúñiga EC, Fong AYY, Alhabib KF, Halvorsen S, et al.
    Clin Cardiol, 2019 Oct;42(10):1028-1040.
    PMID: 31317575 DOI: 10.1002/clc.23232
    Clinical guidelines for the treatment of patients with non-ST-segment elevation myocardial infarction (NSTEMI) recommend an invasive strategy with cardiac catheterization, revascularization when clinically appropriate, and initiation of dual antiplatelet therapy regardless of whether the patient receives revascularization. However, although patients with NSTEMI have a higher long-term mortality risk than patients with ST-segment elevation myocardial infarction (STEMI), they are often treated less aggressively; with those who have the highest ischemic risk often receiving the least aggressive treatment (the "treatment-risk paradox"). Here, using evidence gathered from across the world, we examine some reasons behind the suboptimal treatment of patients with NSTEMI, and recommend approaches to address this issue in order to improve the standard of healthcare for this group of patients. The challenges for the treatment of patients with NSTEMI can be categorized into four "P" factors that contribute to poor clinical outcomes: patient characteristics being heterogeneous; physicians underestimating the high ischemic risk compared with bleeding risk; procedure availability; and policy within the healthcare system. To address these challenges, potential approaches include: developing guidelines and protocols that incorporate rigorous definitions of NSTEMI; risk assessment and integrated quality assessment measures; providing education to physicians on the management of long-term cardiovascular risk in patients with NSTEMI; and making stents and antiplatelet therapies more accessible to patients.
    Matched MeSH terms: Cardiac Catheterization/methods*
  4. Haranal M, Mood MC, Leong MC, Febrianti Z, Abdul Latiff H, Samion H, et al.
    Interact Cardiovasc Thorac Surg, 2020 08 01;31(2):221-227.
    PMID: 32437520 DOI: 10.1093/icvts/ivaa069
    OBJECTIVES: This study aims to review our institutional experience of ductal stenting (DS) on the growth of pulmonary arteries (PAs) and surgical outcomes of PA reconstruction in this subset of patients.

    METHODS: This is a retrospective study done in neonates and infants up to 3 months of age with duct-dependent pulmonary circulation who underwent DS from January 2014 to December 2015. Post-stenting PA growth, surgical outcomes of PA reconstruction, post-surgical re-interventions, morbidity and mortality were analysed.

    RESULTS: During the study period, 46 patients underwent successful DS, of whom 38 underwent presurgery catheterization and definite surgery. There was significant growth of PAs in these patients. Biventricular repair was done in 31 patients while 7 had univentricular palliation. Left PA augmentation was required in 13 patients, and 10 required central PA augmentation during surgery. The mean follow-up period post-surgery was 4.5 ± 1.5 years. No significant postoperative complications were seen. No early or follow-up post-surgery mortality was seen. Four patients required re-interventions in the form of left PA stenting based on the echocardiography or computed tomography evidence of significant stenosis.

    CONCLUSIONS: DS provides good short-term palliation and the growth of PAs. However, a significant number of stented patients require reparative procedure on PAs at the time of surgical intervention. Acquired changes in the PAs following DS may be the reason for reintervention following PA reconstruction.

    Matched MeSH terms: Cardiac Catheterization/methods*
  5. Liu WJ, Hooi LS
    Perit Dial Int, 2010 03 12;30(5):509-12.
    PMID: 20228175 DOI: 10.3747/pdi.2009.00083
    OBJECTIVE: To analyze the complications after Tenckhoff catheter insertion among patients with renal failure needing dialysis. ♢

    PATIENTS AND METHODS: The open, paramedian approach is the commonest technique to insert the 62-cm coiled double-cuffed Tenckhoff peritoneal catheter. All patients with catheters inserted between January 2004 and November 2007 were retrospectively analyzed for demographics and followed for up to 1 month for complications. We excluded patients whose catheters had been anchored to the bladder wall and who underwent concurrent omentectomy or readjustment without removal of a malfunctioning catheter (n = 7). Intravenous cloxacillin was the standard preoperative antibiotic prophylaxis. ♢

    RESULTS: Over the 4-year study period, 384 catheters were inserted under local anesthetic into 319 patients [201 women (62.8%); mean age: 49.4 ± 16.7 years (range: 13 - 89 years); 167 (52.2%) with diabetes; 303 (95%) with end-stage renal disease] by 22 different operators. All Tenckhoff catheters were inserted by the general surgical (n = 223) or urology (n = 161) team. There were 29 cases (7.6%) of catheter migration, 22 (5.7%) of catheter obstruction without migration, 24 (6.3%) of exit-site infection, 12 (3.1%) of leak from the main incision, 14 (3.6%) of culture-proven wound infection, 11 (2.9%) post-insertion peritonitis, and 1 (0.3%) hemoperitoneum. No deaths were attributed to surgical mishap. ♢

    CONCLUSIONS: The most common complication was catheter migration. The paramedian insertion technique was safe, with low complication rates.

    Matched MeSH terms: Catheterization/methods
  6. Riahi M, Ang HL, Jones M, Prachasilchai P, Baruteau AE, Promphan W, et al.
    Circ Cardiovasc Interv, 2018 04;11(4):e005923.
    PMID: 29618579 DOI: 10.1161/CIRCINTERVENTIONS.117.005923
    Matched MeSH terms: Cardiac Catheterization/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links