Displaying publications 41 - 50 of 50 in total

Abstract:
Sort:
  1. Madfa AA, Kadir MR, Kashani J, Saidin S, Sulaiman E, Marhazlinda J, et al.
    Med Eng Phys, 2014 Jul;36(7):962-7.
    PMID: 24834856 DOI: 10.1016/j.medengphy.2014.03.018
    Different dental post designs and materials affect the stability of restoration of a tooth. This study aimed to analyse and compare the stability of two shapes of dental posts (parallel-sided and tapered) made of five different materials (titanium, zirconia, carbon fibre and glass fibre) by investigating their stress transfer through the finite element (FE) method. Ten three-dimensional (3D) FE models of a maxillary central incisor restored with two different designs and five different materials were constructed. An oblique loading of 100 N was applied to each 3D model. Analyses along the centre of the post, the crown-cement/core and the post-cement/dentine interfaces were computed, and the means were calculated. One-way ANOVAs followed by post hoc tests were used to evaluate the effectiveness of the post materials and designs (p=0.05). For post designs, the tapered posts introduced significantly higher stress compared with the parallel-sided post (p<0.05), especially along the centre of the post. Of the materials, the highest level of stress was found for stainless steel, followed by zirconia, titanium, glass fibre and carbon fibre posts (p<0.05). The carbon and glass fibre posts reduced the stress distribution at the middle and apical part of the posts compared with the stainless steel, zirconia and titanium posts. The opposite results were observed at the crown-cement/core interface.
  2. Aziz SB, Nofal MM, Abdulwahid RT, O Ghareeb H, Dannoun EMA, M Abdullah R, et al.
    Polymers (Basel), 2021 Mar 05;13(5).
    PMID: 33807956 DOI: 10.3390/polym13050803
    This report presents the preparation of plasticized sodium ion-conducting polymer electrolytes based on polyvinyl alcohol (PVA)via solution cast technique. The prepared plasticized polymer electrolytes were utilized in the device fabrication of electrical double-layer capacitors (EDLCs). On an assembly EDLC system, cyclic voltammetry (CV), electrical impedance spectroscopy (EIS), linear sweep voltammetry (LSV), transfer number measurement (TNM) and charge-discharging responses were performed. The influence of plasticization on polymer electrolytes was investigated in terms of electrochemical properties applying EIS and TNM. The EIS was fitted with electrical equivalent circuit (EEC) models and ion transport parameters were estimated with the highest conductivity of 1.17 × 10-3 S cm-1 was recorded. The CV and charge-discharging responses were used to evaluate the capacitance and the equivalent series resistance (ESR), respectively. The ESR of the highest conductive sample was found to be 91.2 Ω at the first cycle, with the decomposition voltage of 2.12 V. The TNM measurement has shown the dominancy of ions with tion = 0.982 for the highest conducting sample. The absence of redox peaks was proved via CV, indicating the charge storing process that comprised ion accumulation at the interfacial region. The fabricated EDLC device is stable for up to 400 cycles. At the first cycle, a high specific capacitance of 169 F/g, an energy density of 19 Wh/kg, and a power density of 600 W/kg were obtained.
  3. Aziz SB, Dannoun EMA, Hamsan MH, Abdulwahid RT, Mishra K, Nofal MM, et al.
    Membranes (Basel), 2021 Apr 14;11(4).
    PMID: 33920053 DOI: 10.3390/membranes11040289
    The current work shows the preparation of plasticized chitosan-magnesium acetate Mg(CH3COO)2-based polymer electrolyte dispersed with nickel (Ni) metal complexes via solution casting. Investigations of electrical and electrochemical properties of the prepared polymer composite electrolyte were carried out. The structural and optical properties of the samples were studied using X-ray diffraction (XRD) and UV-Vis spectroscopy techniques. The structural and optical outcomes revealed a clear enhancement in both absorbance and amorphous nature of the samples upon the addition of Ni metal complexes. Through the simulation of impedance data, various ion transport parameters were calculated. The electrochemical performance of the sample was examined by means of transference number measurement (TNM), linear sweep voltammetry (LSV) and cyclic voltammetry (CV) measurements. The TNM analysis confirmed the dominance of ions as the main charge carrier in the electrolyte with tion of (0.96) compared to only (0.04) for tel. The present electrolyte was stable in the range of 0 V to 2.4 V, which was obtained from linear sweep voltammetry (LSV). A result from CV proved that the electrical double-layer capacitor (EDLC) has a capacitive behavior as no redox peaks could be observed. The presence of Ni improved the charge-discharge cycle of the EDLC due to its amorphous behavior. The average performances of the EDLC were recorded as 41.7 F/g, 95%, 5.86 Wh/kg and 628 W/kg for specific capacitance, coulombic efficiency, energy and power densities, respectively. The fabricated EDLC device was found to be stable up to 1000 cycles.
  4. M Nofal M, Aziz SB, Hadi JM, Abdulwahid RT, Dannoun EMA, Marif AS, et al.
    Materials (Basel), 2020 Oct 30;13(21).
    PMID: 33143345 DOI: 10.3390/ma13214890
    In this study, porous cationic hydrogen (H+) conducting polymer blend electrolytes with an amorphous structure were prepared using a casting technique. Poly(vinyl alcohol) (PVA), chitosan (CS), and NH4SCN were used as raw materials. The peak broadening and drop in intensity of the X-ray diffraction (XRD) pattern of the electrolyte systems established the growth of the amorphous phase. The porous structure is associated with the amorphous nature, which was visualized through the field-emission scanning electron microscope (FESEM) images. The enhancement of DC ionic conductivity with increasing salt content was observed up to 40 wt.% of the added salt. The dielectric and electric modulus results were helpful in understanding the ionic conductivity behavior. The transfer number measurement (TNM) technique was used to determine the ion (tion) and electron (telec) transference numbers. The high electrochemical stability up to 2.25 V was recorded using the linear sweep voltammetry (LSV) technique.
  5. Aziz SB, Brevik I, Brza MA, Asnawi ASFM, Dannoun EMA, Yusof YM, et al.
    Materials (Basel), 2020 Nov 07;13(21).
    PMID: 33171877 DOI: 10.3390/ma13215030
    In this study, structural characterization, electrical properties and energy storage performance of plasticized polymer electrolytes based on polyvinyl alcohol/methylcellulose/ammonium thiocyanate (PVA/MC-NH4SCN) were carried out. An X-ray diffraction (XRD) study displayed that the plasticized electrolyte system with the uppermost value of direct current (DC) ionic conductivity was the most amorphous system. The electrolyte in the present work realized an ionic conductivity of 2.903 × 10-3 Scm-1 at room temperature. The main charge carrier in the electrolyte was found to be the ions with the ionic transference number (tion) of 0.912, compared to only 0.088 for the electronic transference number (telec). The electrochemical stability potential window of the electrolyte is 2.1 V. The specific capacitance was found to reduce from 102.88 F/g to 28.58 F/g as the scan rate increased in cyclic voltammetry (CV) analysis. The fabricated electrochemical double layer capacitor (EDLC) was stable up to 200 cycles with high efficiency. The specific capacitance obtained for the EDLC by using charge-discharge analysis was 132.7 F/g at the first cycle, which is slightly higher compared to the CV plot. The equivalent series resistance (ESR) increased from 58 to 171 Ω throughout the cycles, which indicates a good electrolyte/electrode contact. Ions in the electrolyte were considered to have almost the same amount of energy during the conduction process as the energy density is approximately at 14.0 Wh/kg throughout the 200 cycles. The power density is stabilized at the range of 1444.3 to 467.6 W/kg as the EDLC completed the cycles.
  6. Aziz SB, Murad AR, Abdulwahid RT, Aziz DM, Abdalrahman AA, Abdullah RM, et al.
    Int J Biol Macromol, 2024 Jul;273(Pt 2):133203.
    PMID: 38885860 DOI: 10.1016/j.ijbiomac.2024.133203
    This study investigates the performance of biopolymer electrolytes based on chitosan and dextran for energy storage applications. The optimization of ion transport and performance of electric double-layer capacitors EDCL using these electrolytes, incorporating different concentrations of glycerol as a plasticizer and TiO2 as nanoparticles, is explored. Impedance measurements indicate a notable reduction in charge transfer resistance with the addition of TiO2. DC conductivity estimates from AC spectra plateau regions reach up to 5.6 × 10-4 S/cm. The electric bulk resistance Rb obtained from the Nyquist plots exhibits a substantial decrease with increasing plasticizer concentration, further enhanced by the addition of the nanoparticles. Specifically, Rb decreases from ∼20 kΩ to 287 Ω when glycerol concentration increases from 10 % to 40 % and further drops to 30 Ω with the introduction of TiO2. Specific capacitance obtained from cyclic voltammetry shows a notable increase as the scan rate decreases, indicating improved efficiency and stability of ion transport. The TiO2-enriched EDCL achieves 12.3 F/g specific capacitance at 20 mV/s scan rate, with high ion conductivity and extended electrochemical stability. These results suggest the great potential of plasticizer and TiO2 with biopolymers in improving the performance of energy storage systems.
  7. Coggon D, Ntani G, Palmer KT, Felli VE, Harari R, Barrero LH, et al.
    Pain, 2013 Sep;154(9):1769-1777.
    PMID: 23727463 DOI: 10.1016/j.pain.2013.05.039
    To explore definitions for multisite pain, and compare associations with risk factors for different patterns of musculoskeletal pain, we analysed cross-sectional data from the Cultural and Psychosocial Influences on Disability (CUPID) study. The study sample comprised 12,410 adults aged 20-59 years from 47 occupational groups in 18 countries. A standardised questionnaire was used to collect information about pain in the past month at each of 10 anatomical sites, and about potential risk factors. Associations with pain outcomes were assessed by Poisson regression, and characterised by prevalence rate ratios (PRRs). Extensive pain, affecting 6-10 anatomical sites, was reported much more frequently than would be expected if the occurrence of pain at each site were independent (674 participants vs 41.9 expected). In comparison with pain involving only 1-3 sites, it showed much stronger associations (relative to no pain) with risk factors such as female sex (PRR 1.6 vs 1.1), older age (PRR 2.6 vs 1.1), somatising tendency (PRR 4.6 vs 1.3), and exposure to multiple physically stressing occupational activities (PRR 5.0 vs 1.4). After adjustment for number of sites with pain, these risk factors showed no additional association with a distribution of pain that was widespread according to the frequently used American College of Rheumatology criteria. Our analysis supports the classification of pain at multiple anatomical sites simply by the number of sites affected, and suggests that extensive pain differs importantly in its associations with risk factors from pain that is limited to only a small number of anatomical sites.
  8. Vargas-Prada S, Coggon D, Ntani G, Walker-Bone K, Palmer KT, Felli VE, et al.
    PLoS One, 2016;11(4):e0153748.
    PMID: 27128094 DOI: 10.1371/journal.pone.0153748
    Somatising tendency, defined as a predisposition to worry about common somatic symptoms, is importantly associated with various aspects of health and health-related behaviour, including musculoskeletal pain and associated disability. To explore its epidemiological characteristics, and how it can be specified most efficiently, we analysed data from an international longitudinal study. A baseline questionnaire, which included questions from the Brief Symptom Inventory about seven common symptoms, was completed by 12,072 participants aged 20-59 from 46 occupational groups in 18 countries (response rate 70%). The seven symptoms were all mutually associated (odds ratios for pairwise associations 3.4 to 9.3), and each contributed to a measure of somatising tendency that exhibited an exposure-response relationship both with multi-site pain (prevalence rate ratios up to six), and also with sickness absence for non-musculoskeletal reasons. In most participants, the level of somatising tendency was little changed when reassessed after a mean interval of 14 months (75% having a change of 0 or 1 in their symptom count), although the specific symptoms reported at follow-up often differed from those at baseline. Somatising tendency was more common in women than men, especially at older ages, and varied markedly across the 46 occupational groups studied, with higher rates in South and Central America. It was weakly associated with smoking, but not with level of education. Our study supports the use of questions from the Brief Symptom Inventory as a method for measuring somatising tendency, and suggests that in adults of working age, it is a fairly stable trait.
  9. Sarquis LMM, Coggon D, Ntani G, Walker-Bone K, Palmer KT, Felli VE, et al.
    Pain, 2016 May;157(5):1028-1036.
    PMID: 26761390 DOI: 10.1097/j.pain.0000000000000477
    To inform case definition for neck/shoulder pain in epidemiological research, we compared levels of disability, patterns of association, and prognosis for pain that was limited to the neck or shoulders (LNSP) and more generalised musculoskeletal pain that involved the neck or shoulder(s) (GPNS). Baseline data on musculoskeletal pain, disability, and potential correlates were collected by questionnaire from 12,195 workers in 47 occupational groups (mostly office workers, nurses, and manual workers) in 18 countries (response rate = 70%). Continuing pain after a mean interval of 14 months was ascertained through a follow-up questionnaire in 9150 workers from 45 occupational groups. Associations with personal and occupational factors were assessed by Poisson regression and summarised by prevalence rate ratios (PRRs). The 1-month prevalence of GPNS at baseline was much greater than that of LNSP (35.1% vs 5.6%), and it tended to be more troublesome and disabling. Unlike LNSP, the prevalence of GPNS increased with age. Moreover, it showed significantly stronger associations with somatising tendency (PRR 1.6 vs 1.3) and poor mental health (PRR 1.3 vs 1.1); greater variation between the occupational groups studied (prevalence ranging from 0% to 67.6%) that correlated poorly with the variation in LNSP; and was more persistent at follow-up (72.1% vs 61.7%). Our findings highlight important epidemiological distinctions between subcategories of neck/shoulder pain. In future epidemiological research that bases case definitions on symptoms, it would be useful to distinguish pain that is localised to the neck or shoulder from more generalised pain that happens to involve the neck/shoulder region.
  10. Coggon D, Ntani G, Walker-Bone K, Palmer KT, Felli VE, Harari R, et al.
    Spine (Phila Pa 1976), 2017 May 15;42(10):740-747.
    PMID: 27820794 DOI: 10.1097/BRS.0000000000001956
    STUDY DESIGN: A cross-sectional survey with a longitudinal follow-up.

    OBJECTIVES: The aim of this study was to test the hypothesis that pain, which is localized to the low back, differs epidemiologically from that which occurs simultaneously or close in time to pain at other anatomical sites SUMMARY OF BACKGROUND DATA.: Low back pain (LBP) often occurs in combination with other regional pain, with which it shares similar psychological and psychosocial risk factors. However, few previous epidemiological studies of LBP have distinguished pain that is confined to the low back from that which occurs as part of a wider distribution of pain.

    METHODS: We analyzed data from CUPID, a cohort study that used baseline and follow-up questionnaires to collect information about musculoskeletal pain, associated disability, and potential risk factors, in 47 occupational groups (office workers, nurses, and others) from 18 countries.

    RESULTS: Among 12,197 subjects at baseline, 609 (4.9%) reported localized LBP in the past month, and 3820 (31.3%) nonlocalized LBP. Nonlocalized LBP was more frequently associated with sciatica in the past month (48.1% vs. 30.0% of cases), occurred on more days in the past month and past year, was more often disabling for everyday activities (64.1% vs. 47.3% of cases), and had more frequently led to medical consultation and sickness absence from work. It was also more often persistent when participants were followed up after a mean of 14 months (65.6% vs. 54.1% of cases). In adjusted Poisson regression analyses, nonlocalized LBP was differentially associated with risk factors, particularly female sex, older age, and somatizing tendency. There were also marked differences in the relative prevalence of localized and nonlocalized LBP by occupational group.

    CONCLUSION: Future epidemiological studies should distinguish where possible between pain that is limited to the low back and LBP that occurs in association with pain at other anatomical locations.

    LEVEL OF EVIDENCE: 2.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links