Displaying publications 41 - 60 of 117 in total

Abstract:
Sort:
  1. Makhsin SR, Razak KA, Noordin R, Zakaria ND, Chun TS
    Nanotechnology, 2012 Dec 14;23(49):495719.
    PMID: 23164811 DOI: 10.1088/0957-4484/23/49/495719
    This study describes the properties of colloidal gold nanoparticles (AuNPs) with sizes of 20, 30 and 40 nm, which were synthesized using citrate reduction or seeding-growth methods. Likewise, the conjugation of these AuNPs to mouse anti-human IgG(4) (MαHIgG(4)) was evaluated for an immunochromatographic (ICG) strip test to detect brugian filariasis. The morphology of the AuNPs was studied based on the degree of ellipticity (G) of the transmission electron microscopy images. The AuNPs produced using the seeding-growth method showed lower ellipticity (G ≤ 1.11) as compared with the AuNPs synthesized using the citrate reduction method (G ≤ 1.18). Zetasizer analysis showed that the AuNPs that were synthesized using the seeding-growth method were almost monodispersed with a lower polydispersity index (PDI; PDI≤0.079), as compared with the AuNPs synthesized using the citrate reduction method (PDI≤0.177). UV-visible spectroscopic analysis showed a red-shift of the absorbance spectra after the reaction with MαHIgG(4), which indicated that the AuNPs were successfully conjugated. The optimum concentration of the BmR1 recombinant antigen that was immobilized on the surface of the ICG strip on the test line was 1.0 mg ml(-1). When used with the ICG test strip assay and brugian filariasis serum samples, the conjugated AuNPs-MαHIgG(4) synthesized using the seeding-growth method had faster detection times, as compared with the AuNPs synthesized using the citrate reduction method. The 30 nm AuNPs-MαHIgG(4), with an optical density of 4 from the seeding-growth method, demonstrated the best performance for labelling ICG strips because it displayed the best sensitivity and the highest specificity when tested with serum samples from brugian filariasis patients and controls.
  2. Mirzadeh A, Saadatnia G, Golkar M, Babaie J, Noordin R
    Protein Expr Purif, 2017 05;133:66-74.
    PMID: 28263855 DOI: 10.1016/j.pep.2017.03.001
    SAG1-related sequence 3 (SRS3) is one of the major Toxoplasma gondii tachyzoite surface antigens and has been shown to be potentially useful for the detection of toxoplasmosis. This protein is highly conformational due to the presence of six disulfide bonds. To achieve solubility and antigenicity, SRS3 depends on proper disulfide bond formation. The aim of this study was to over-express the SRS3 protein with correct folding for use in serodiagnosis of the disease. To achieve this, a truncated SRS3 fusion protein (rtSRS3) was produced, containing six histidyl residues at both terminals and purified by immobilized metal affinity chromatography. The refolding process was performed through three methods, namely dialysis in the presence of chemical additives along with reduced/oxidized glutathione and drop-wise dilution methods with reduced/oxidized glutathione or reduced DTT/oxidized glutathione. Ellman's assay and ELISA showed that the protein folding obtained by the dialysis method was the most favorable, probably due to the correct folding. Subsequently, serum samples from individuals with chronic infection (n = 76), probable acute infection (n = 14), and healthy controls (n = 81) were used to determine the usefulness of the refolded rtSRS3 for Toxoplasma serodiagnosis. The results of the developed IgG-ELISA showed a diagnostic specificity of 91% and a sensitivity of 82.89% and 100% for chronic and acute serum samples, respectively. In conclusion, correctly folded rtSRS3 has the potential to be used as a soluble antigen for the detection of human toxoplasmosis.
  3. Moghadam ZK, Ghaffarifar F, Khalilpour A, Abdul Aziz F, Saadatnia G, Noordin R
    Clin Vaccine Immunol, 2013 Apr;20(4):501-5.
    PMID: 23365208 DOI: 10.1128/CVI.00019-13
    Hydatidosis is a public health problem in many parts of the world, and improvement in diagnosis of the disease is still being pursued. Protoscoleces of Echinococcus granulosus were isolated from hydatid cysts collected from naturally infected sheep slaughtered in abattoirs in Iran. Sonicated extract of protoscolex was subjected to two-dimensional gel electrophoresis and Western blot analysis. Primary antibodies were from serum samples from 130 hydatidosis patients, 38 individuals infected with other parasitic infections, and 30 healthy people, whereas peroxidase (HRP)-conjugated anti-human IgG and IgG4 were used as secondary antibodies. The recombinant form of the identified protein was produced and tested for its sensitivity and specificity for the detection of human hydatidosis. An antigenic band of ∼60 kDa was found to be sensitive (82%) and specific (100%) for the detection of hydatidosis when probed with anti-human IgG4-HRP, while the sensitivity and specificity were 33 and 100%, respectively, with anti-human IgG-HRP. By mass spectrometry, the band was identified as protoscolex tegument paramyosin. The sensitivity and specificity of full-length paramyosin-recombinant protein in IgG4 blots were found to be 86 and 98%, respectively. In conclusion, IgG4 detection of Echinococcus granulosus paramyosin was found to be useful for the diagnosis of human hydatidosis.
  4. Mohamad S, Azmi NC, Noordin R
    J Clin Microbiol, 2009 Jun;47(6):1712-7.
    PMID: 19369434 DOI: 10.1128/JCM.00001-09
    Diagnosis of human toxocariasis currently relies on serologic tests that use Toxocara excretory-secretory (TES) antigen to detect immunoglobulin G (IgG) antibodies to the larvae. In general, however, these assays do not have adequate specificity for use in countries in which other soil-transmitted helminths are endemic. The use of recombinant antigens in these assays, however, is promising for improving the specificity of the diagnosis of toxocariasis. Toward this goal, we developed an IgG4 enzyme-linked immunosorbent assay (ELISA) involving three recombinant antigens: rTES-30USM (previously produced), rTES-26, and rTES-120. The latter two antigens were produced by reverse transcription-PCR cloning; subcloned into glutathione S-transferase (GST)-tagged and His-tagged prokaryotic expression vectors, respectively; and expressed in Escherichia coli. The recombinant proteins were subsequently purified by affinity chromatography using GST and His-Trap resins. The diagnostic potential of each purified recombinant antigen was tested with various immunoglobulin classes (IgG, IgM, and IgE) and IgG subclasses. The IgG4 ELISA was determined to have the highest specificity and was further evaluated using a panel of serum samples. The rTES-26 IgG4 ELISA showed 80.0% (24/30 samples positive) sensitivity, and both the rTES-30USM IgG4 ELISA and rTES-120 IgG4 ELISA had 93.0% (28/30) sensitivity. Combined use of rTES-120 and rTES-30 IgG4 ELISA for the diagnosis of toxocariasis provided 100% sensitivity. The specificities of rTES-26, rTES-30USM, and rTES-120 antigens were 96.2%, 93.9%, and 92.0%, respectively. These results indicate that the development of a diagnostic test using the three recombinant antigens will allow for more-accurate detection of toxocariasis.
  5. Mohd Hanafiah K, Arifin N, Bustami Y, Noordin R, Garcia M, Anderson D
    Diagnostics (Basel), 2017 Sep 07;7(3).
    PMID: 28880218 DOI: 10.3390/diagnostics7030051
    Lateral flow assays (LFAs) are the mainstay of rapid point-of-care diagnostics, with the potential to enable early case management and transform the epidemiology of infectious disease. However, most LFAs only detect single biomarkers. Recognizing the complex nature of human disease, overlapping symptoms and states of co-infections, there is increasing demand for multiplexed systems that can detect multiple biomarkers simultaneously. Due to innate limitations in the design of traditional membrane-based LFAs, multiplexing is arguably limited to a small number of biomarkers. Here, we summarize the need for multiplexed LFA, key technical and operational challenges for multiplexing, inherent in the design and production of multiplexed LFAs, as well as emerging enabling technologies that may be able to address these challenges. We further identify important areas for research in efforts towards developing multiplexed LFAs for more impactful diagnosis of infectious diseases.
  6. Mohd-Hassan NH, Noordin R, Arifin N
    Trop Biomed, 2020 Sep 01;37(3):578-586.
    PMID: 33612773 DOI: 10.47665/tb.37.3.578
    Strongyloidiasis is a mysterious yet important parasitic disease that is hard to diagnose. While microscopic examination remains a "controversial" gold standard method, improved diagnosis is achieved through confirmatory assays with serological and/or molecular diagnostic approaches. In the current serodiagnosis of strongyloidiasis, recombinant proteins have been adopted in place of the use of native parasite antigens, although the availability of diagnostically potential proteins are still limited. Here, we introduce a novel Strongyloides recombinant protein that is uniquely attached to two different short peptide tags as a potential diagnostic biomarker for serodiagnosis of strongyloidiasis, namely lysine (7K) and aspartic acid (7D). The work presented focus on improving the yield and purity of the previously unexpressed recombinant protein. Preliminary diagnostic evaluation of the recombinant favors Ss3a7K protein owing to its higher antigenicity performance with 80% sensitivity and 100% specificity, respectively.
  7. Ng YL, Olivos-García A, Lim TK, Noordin R, Lin Q, Othman N
    Am J Trop Med Hyg, 2018 12;99(6):1518-1529.
    PMID: 30298805 DOI: 10.4269/ajtmh.18-0415
    Entamoeba histolytica is a protozoan parasite that causes amebiasis and poses a significant health risk for populations in endemic areas. The molecular mechanisms involved in the pathogenesis and regulation of the parasite are not well characterized. We aimed to identify and quantify the differentially abundant membrane proteins by comparing the membrane proteins of virulent and avirulent variants of E. histolytica HM-1:IMSS, and to investigate the potential associations among the differentially abundant membrane proteins. We performed quantitative proteomics analysis using isobaric tags for relative and absolute quantitation labeling, in combination with two mass spectrometry instruments, that is, nano-liquid chromatography (nanoLC)-matrix-assisted laser desorption/ionization-mass spectrometry/mass spectrometry and nanoLC-electrospray ionization tandem mass spectrometry. Overall, 37 membrane proteins were found to be differentially abundant, whereby 19 and 18 membrane proteins of the virulent variant of E. histolytica increased and decreased in abundance, respectively. Proteins that were differentially abundant include Rho family GTPase, calreticulin, a 70-kDa heat shock protein, and hypothetical proteins. Analysis by Protein ANalysis THrough Evolutionary Relationships database revealed that the differentially abundant membrane proteins were mainly involved in catalytic activities (29.7%) and metabolic processes (32.4%). Differentially abundant membrane proteins that were found to be involved mainly in the catalytic activities and the metabolic processes were highlighted together with their putative roles in relation to the virulence. Further investigations should be performed to elucidate the roles of these proteins in E. histolytica pathogenesis.
  8. Ning TZ, Kin WW, Noordin R, Cun ST, Chong FP, Mohamed Z, et al.
    BMC Infect Dis, 2013;13:144.
    PMID: 23514636 DOI: 10.1186/1471-2334-13-144
    Amoebic liver abscess (ALA) is the most frequent clinical presentation of extra-intestinal amoebiasis. The diagnosis of ALA is typically based on the developing clinical symptoms, characteristic changes on radiological imaging and serology. Numerous serological tests have been introduced for the diagnosis of ALA, either detecting circulating amoebic antigens or antibodies. However those tests show some pitfalls in their efficacy and/or the preparation of the tests are costly and tedious. The commercial IHA kit that used crude antigen was reported to be useful in diagnosis of ALA, however high antibody background in endemic areas may cause problems in its interpretation. Thus, discovery of well-defined antigen(s) is urgently needed to improve the weaknesses of current serodiagnostic tests.
  9. Ning TZ, Kin WW, Mustafa S, Ahmed A, Noordin R, Cheong TG, et al.
    Asian Pac J Trop Biomed, 2012 Jan;2(1):61-5.
    PMID: 23569836 DOI: 10.1016/S2221-1691(11)60191-3
    To compare the efficacy of three different tissue stains, namely haematoxylin and eosin (H&E), periodic-acid Schiff (PAS) and immunohistochemical (IHC) stains for detection of Entamoeba histolytica (E. histolytica) trophozoites in abscessed liver tissues of hamster.
  10. Noordin R, Itoh M, Kimura E, Abdul Rahman R, Ravindran B, Mahmud R, et al.
    Filaria journal, 2007;6:9.
    PMID: 17961262
    In the global effort to eliminate lymphatic filariasis (LF), rapid field-applicable tests are useful tools that will allow on-site testing to be performed in remote places and the results to be obtained rapidly. Exclusive reliance on the few existing tests may jeopardize the progress of the LF elimination program, thus the introduction of other rapid tests would be useful to address this issue. Two new rapid immunochromatographic IgG4 cassette tests have been produced, namely WB rapid and panLF rapid, for detection of bancroftian filariasis and all three species of lymphatic filaria respectively. WB rapid was developed using BmSXP recombinant antigen, while PanLF rapid was developed using BmR1 and BmSXP recombinant antigens. A total of 165 WB rapid and 276 panLF rapid tests respectively were evaluated at USM and the rest were couriered to another university in Malaysia (98 WB rapid, 129 panLF rapid) and to universities in Indonesia (56 WB rapid, 62 panLF rapid), Japan (152 of each test) and India (18 of each test) where each of the tests underwent independent evaluations in a blinded manner. The average sensitivities of WB rapid and panLF rapid were found to be 97.6% (94%-100%) and 96.5% (94%-100%) respectively; while their average specificities were both 99.6% (99%-100%). Thus this study demonstrated that both the IgG4 rapid tests were highly sensitive and specific, and would be useful additional tests to facilitate the global drive to eliminate this disease.
  11. Noordin R, Aziz RA, Ravindran B
    Filaria journal, 2004 Dec 31;3(1):10.
    PMID: 15627400
    BACKGROUND: The recombinant antigen BmR1 has been extensively employed in both ELISA and immunochromatographic rapid dipstick (Brugia Rapid) formats for the specific and sensitive detection of IgG4 antibodies against the lymphatic filarial parasites Brugia malayi and Brugia timori. In sera of individuals infected with Wuchereria bancrofti the IgG4 reactivity to BmR1 is variable, and cross-reactivity of sera from individuals infected with Onchocerca volvulus or Loa loa was observed only in single cases. In order to characterize the homologs of the BmR1 antigen in W. bancrofti (Wb-BmR1), O. volvulus (Ov-BmR1) and L. loa (Ll-BmR1) the cDNA sequences were identified, the protein expressed and the antibody reactivity of patients' sera was studied. METHODS: PCR methodology was used to identify the cDNA sequences from cDNA libraries and/or genomic DNA of W. bancrofti, O. volvulus and L. loa. The clones obtained were sequenced and compared to the cDNA sequence of BmR1. Ov-BmR1 and Ll-BmR1 were expressed in E. coli and tested using an IgG4-ELISA with 262 serum samples from individuals with or without B. malayi, W. bancrofti, O. volvulus and L. loa infections or various other parasitic infections. BmR1, Ov-BmR1 and Ll-BmR1 were also tested for reactivity with the other three IgG subclasses in patients' sera. RESULTS: Wb-BmR1 was found to be identical to BmR1. Ov-BmR1 and Ll-BmR1 were found to be identical to each other and share 99.7% homology with BmR1. The pattern of IgG4 recognition of all serum samples to BmR1, Ov-BmR1 and Ll-BmR1 were identical. This included weak IgG4 reactivities demonstrated by L. loa- and O. volvulus-infected patients tested with Ov-BmR1 and Ll-BmR1 (or BmR1). With respect to reactivity to other IgG subclasses, sera from O. volvulus- and L. loa-infected patients showed positive reactions (when tested with BmR1, Ov-BmR1 or Ll-BmR1 antigens) only with IgG1. No reactivity was observed with IgG2 or with IgG3. Similarly, ELISAs to detect reactivity to other anti-filarial IgG subclasses antibodies showed that sera from individuals infected with B. malayi or W. bancrofti (active infections as well as patients with chronic disease) were positive with BmR1 only for IgG1 and were negative when tested with IgG2 and with IgG3 subclasses. CONCLUSIONS: This study demonstrates that homologs of the BmR1 antigen are present in W. bancrofti, O. volvulus and L. loa and that these antigens are highly conserved. Recognition of this antigen by patients' sera is similar with regard to IgG1, IgG2 and IgG3, but different for IgG4 antibodies. We conclude that the BmR1 antigen is suitable for detection of IgG4 antibodies in brugian filariasis. However, its homologs are not suitable for IgG4-based diagnosis of other filarial infections.
  12. Noordin R, Smith HV, Mohamad S, Maizels RM, Fong MY
    Acta Trop, 2005 Jan;93(1):57-62.
    PMID: 15589798
    Diagnosis of human toxocariasis, caused by Toxocara canis or Toxocara cati, normally relies on a combination of the presence of clinical signs and symptoms backed by positive serology. The use of Toxocara excretory-secretory antigen (TES) in ELISA assays increases the test specificity. However, in tropical countries where soil-transmitted helminths are endemic, cross-reactivity from antibodies to these intestinal parasites poses a significant limitation for Toxocara serodiagnosis. To increase the specificity of serodiagnosis, we compared the use of IgG-ELISA to the use of IgG4-ELISA using commercially manufactured TES-coated plates. The sensitivity of the IgG-ELISA was 97.1%, while that of the IgG4-ELISA was 45.7%; the specificities were 36.0 and 78.6%, respectively. The study shows that employing both assays can improve the serodiagnosis of toxocariasis. An IgG4 immunoassay would also be useful in the secondary screening of antigen clones in the effort to develop improved serological tests for toxocariasis.
  13. Noordin R, Wahyuni S, Mangali A, Huat LB, Yazdanbakhsh M, Sartono E
    Filaria journal, 2004 Aug 12;3(1):8.
    PMID: 15307892
    BACKGROUND: Brugia malayi is endemic in several Asian countries with the highest prevalence in Indonesia. Determination of prevalence of lymphatic filariasis by serology has been performed by various investigators using different kinds of antigen (either soluble worm antigen preparations or recombinant antigens). This investigation compared the data obtained from IgG4 assays using two different kinds of antigen in a study on prevalence of antibodies to B. malayi. METHODS: Serum samples from a transmigrant population and life long residents previously tested with IgG4 assay using soluble worm antigen (SWA-ELISA), were retested with an IgG4 assay that employs BmR1 recombinant antigen (BmR1 dipstick [Brugia Rapid trade mark ]). The results obtained with the two antigens were compared, using Pearson chi-square and McNemar test. RESULTS: There were similarities and differences in the results obtained using the two kinds of antigen (SWA and BmR1). Similarities included the observation that assays using both antigens demonstrated an increasing prevalence of IgG4 antibodies in the transmigrant population with increasing exposure to the infection, and by six years living in the area, antibody prevalence was similar to that of life-long residents. With regards to differences, of significance is the demonstration of similar antibody prevalence in adults and children by BmR1 dipstick whereas by SWA-ELISA the antibody prevalence in adults was higher than in children. CONCLUSIONS: Results and conclusions made from investigations of prevalence of anti-filarial IgG4 antibody in a population would be affected by the assay employed in the study.
  14. Noordin R, Abdullah KA, Azahri NA, Ramachandran CP
    PMID: 10928359
    Western blot analysis of infective larvae (L3) antigen of Brugia malayi were performed on 200 sera from six groups of individuals: 36 samples from B. malayi microfilaremic individuals; 10 samples from individuals with elephantiasis; 50 and 20 samples from amicrofilaremic individuals in a B. malayi endemic area with no anti-filarial IgG4 antibodies (towards microfilaria and adult worm antigens) and samples with high titres of the anti-filarial IgG4 antibodies respectively; 50 samples from non-endemic normals and 34 samples from geohelminth-infected individuals. After protein transfer, PVDF membrane strips were successively incubated with blocking solution, human sera, monoclonal anti-human IgG4 antibody-HRP and developed with luminol chemiluminescence substrate. 28/36 (78%), 1/10 (10%) and 16/20(80%) of sera from individuals with microfilariae, elephantiasis and amicrofilaremic individuals with high titers of anti-filarial IgG4 antibodies respectively recognized L3 antigenic epitopes; the dominant and consistent antigenic bands were of approximately MW 43 kDa, 14 kDa, 15 kDa and 59 kDa. The rest of the sera were unreactive. This study showed that microfilaremics may or may not mount a notable antibody response to somatic L3 antigens, thus lending evidence that antibody response to this antigen is not protective against establishment of Brugia malayi infection.
  15. Noordin R, Shenoy RK, Rahman RA
    PMID: 15115085
    Brugia malayi infection is endemic in several Asian countries. Filaria-specific IgG4 antibody detection based on BmR1 recombinant antigen has been shown to be sensitive and specific for the diagnosis of brugian filariasis. Two formats of the test has been reported ie indirect ELISA (BE) and rapid dipstick test (BR). Since different test formats use different amounts of sample and reagents which may affect its sensitivity and specificity, this study was performed to compare these two test formats in the detection of B. malayi. A total of 264 blinded serum samples from India and Malaysia were employed. Group 1 comprised 164 samples from actively infected individuals and group 2 comprised 100 samples from filaria non-endemic areas. Sensitivity was 96.3% (158/164) and 90.8% (149/164) for rapid test and ELISA respectively; chi-square p=0.00. Both test formats demonstrated 100% specificity. Therefore the rapid test format was equally specific but more sensitive than the ELISA format. The ELISA format would be able to demonstrate decline in IgG4 titer post-treatment while the rapid test would be very useful for screening and diagnosis in the field.
  16. Noordin R, Khanbabaie S, Hafiznur Yunus M, Marti H, Nickel B, Fasihi Harandi M, et al.
    Iran J Parasitol, 2020 10 22;15(3):290-298.
    PMID: 33082792 DOI: 10.18502/ijpa.v15i3.4191
    Background: Human echinococcosis is a neglected zoonotic disease distributed worldwide. It comprises cystic and alveolar forms, the former being the more prevalent disease. Imaging techniques are the first choice for diagnosis of cystic echinococcosis and serology is used as an additional diagnostic technique in doubtful cases or as the sole test in low-resource settings. Rapid diagnostic tests are useful and convenient for immunodiagnosis of cystic echinococcosis in endemic areas, where medical facilities often struggle with limited resources.

    Methods: Recently, we have developed Hyd Rapid™, an IgG4 lateral flow dipstick test using recombinant antigen B1 for detection of cystic echinococcosis. This study was performed between 2016 until 2018 at the Institute for Research in Molecular Medicine, Universiti Sains Malaysia. The diagnostic performance of Hyd Rapid™ was tested in-house and at two international laboratories in Switzerland and Iran.

    Results: The overall diagnostic sensitivity for detection of cystic and alveolar echinococcosis was 95% (56/59). Meanwhile, the diagnostic specificity, with and without exclusion of cysticercosis and fascioliasis, was 100% (n=48) and 88% (63/72), respectively.

    Conclusion: Hyd Rapid™ detected cystic echinococcosis as well as probable cases of alveolar echinococcosis. Therefore, Hyd Rapid™ showed good potential as a serological tool for echinococcosis, and merits further evaluation.

  17. Noordin R, Yunus MH, Tan Farrizam SN, Arifin N
    Adv Parasitol, 2020;109:131-152.
    PMID: 32381194 DOI: 10.1016/bs.apar.2020.01.003
    Toxocariasis is a human infection primarily caused by larvae of Toxocara canis from dogs, and also by T. cati from cats. Children have a more significant risk of acquiring the infection due to their closer contact with pets, and greater chances of ingesting soil. Diagnosis of toxocariasis is based on clinical, epidemiological, and serological data. Indirect IgG ELISA is a widely used serodiagnostic method for toxocariasis, with native T. canis TES most commonly used as the antigen. Western blots, using the same antigen, can be used to confirm positive ELISA findings to reduce false-positive results. Improvements in Toxocara serodiagnosis include the use of recombinant TES antigens, simpler and more rapid assay formats, and IgG4 subclass detection. Also, incorporation of recombinant T. cati TES protein increases the diagnostic sensitivity. Development of antigen detection tests using polyclonal and monoclonal antibodies, nanobodies, or aptamers can complement the antibody detection assays, and enhance the effectiveness of the serodiagnosis.
  18. Noordin R, Muhi J, Md Idris Z, Arifin N, Kiyu A
    Trop Biomed, 2012 Mar;29(1):191-6.
    PMID: 22543621 MyJurnal
    The detection rates of brugian filariasis in three regions of Sarawak namely Central, North and South after three courses of mass drug administration (MDA) from year 2004 to 2006 was investigated. A recombinant BmR1 antigen-based IgG4 detection test, named Brugia Rapid and night blood smear for microfilaria (mf) detection were used. All three regions recorded a sharp fall in mf positive rates after a year post-MDA. Meanwhile Brugia Rapid positive rates declined more gradually to 3.8% and 5.6% of the pre-MDA levels in the Central and North regions, respectively. This study showed that in filariasis endemic areas in Sarawak, anti-filarial IgG4 antibodies to BmR1, as detected by the Brugia Rapid test, were positive for one to two years after mf disappearance.
  19. Noordin R, Yunus MH, Robinson K, Won KY, Babu S, Fischer PU, et al.
    Am J Trop Med Hyg, 2018 12;99(6):1587-1590.
    PMID: 30350768 DOI: 10.4269/ajtmh.18-0566
    At the end phase of the Global Programme to Eliminate Lymphatic Filariasis, antibody testing may have a role in decision-making for bancroftian filariasis-endemic areas. This study evaluated the diagnostic performance of BLF Rapid™, a prototype immunochromatographic IgG4-based test using BmSXP recombinant protein, for detection of bancroftian filariasis. The test was evaluated using 258 serum samples, comprising 96 samples tested at Universiti Sains Malaysia (in-house) and 162 samples tested independently at three international laboratories in the USA and India, and two laboratories in Malaysia. The independent testing involved 99 samples from Wuchereria bancrofti microfilaria or antigen positive individuals and 63 samples from people who were healthy or had other infections. The in-house evaluation showed 100% diagnostic sensitivity and specificity. The independent evaluations showed a diagnostic sensitivity of 84-100% and 100% specificity (excluding non-lymphatic filarial infections). BLF Rapid has potential as a surveillance diagnostic tool to make "Transmission Assessment Survey"-stopping decisions and conduct post-elimination surveillance.
  20. Noordin R, Osman E, Kalantari N, Anuar NS, Gorgani-Firouzjaee T, Sithithaworn P, et al.
    Acta Trop, 2022 Feb;226:106251.
    PMID: 34808116 DOI: 10.1016/j.actatropica.2021.106251
    Strongyloides stercoralis is a parasite that causes strongyloidiasis worldwide. It may lead to a life-long infection in immunocompetent people and hyperinfection in immunosuppressed patients. A point-of-care (POC) rapid test is helpful for patient diagnosis in resource-limited settings and as a detection tool in elimination/control programs. Previously, we reported a rapid IgG4 dipstick test (Ss Rapid®) for Strongyloides suitable for a laboratory setting. A POC cassette format of the test, which is field-applicable, has since been developed. Here, we report on a laboratory-based evaluation of the Ss Rapid® cas sette test on 285 sera. We assessed the diagnostic sensitivity of the Ss Rapid® cas sette with 32 sera, comprising samples from larval and/or DNA positive individuals from three countries. Additionally, we also tested samples from 33 seropositive endemic areas residents. We evaluated the diagnostic specificity of the test using 220 samples, comprising sera from other infections (n = 101), allergy cases with high IgE antibodies (n = 4), and blood donors (n = 115). The test showed high diagnostic sensitivity (97%, 31/32), and all sera of the seropositive endemic residents were reactive. It also showed high diagnostic specificity (94.5%, 208/220), and all false-positive samples tested negative after sera adsorption using recombinant NIE-coated microsphere beads. Additionally, we showed that the test worked with spiked whole blood samples. The study results showed that the SsRapid® cas sette test merits further laboratory and field evaluations.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links