Displaying publications 41 - 45 of 45 in total

Abstract:
Sort:
  1. Al Azzam KM, Saad B, Makahleah A, Aboul-Enein HY, Elbashir AA
    Biomed Chromatogr, 2010 May;24(5):535-43.
    PMID: 19739243 DOI: 10.1002/bmc.1323
    A micellar electrokinetic chromatography (MEKC) method for the simultaneous determination of the antiviral drugs acyclovir and valacyclovir and their major impurity, guanine, was developed. The influences of several factors (surfactant and buffer concentration, pH, applied voltage, capillary temperature and injection time) were studied. Using tyramine hydrochloride as internal standard, the analytes were all separated in about 4 min. The separation was carried out in reversed polarity mode at 28 degrees C, 25 kV and using hydrodynamic injection (15 s). The separation was effected in a fused-silica capillary 100 microm x 56 cm and a background electrolyte of 20 mM citric acid-1 M Tris solution (pH 2.75), containing 125 mM sodium dodecyl sulphate and detection at 254 nm. The method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 0.1-1 microg/mL (guanine) and from 0.1 to 120 microg/mL for both valacyclovir and acyclovir. The relative standard deviations of intra- and inter-day migration times and corrected peak areas were less than 5.0%. The proposed method was successfully applied to the determination of the analytes in tablets and creams. From the previous study it is concluded that the stability-indicating method developed for acyclovir and valacyclovir can be used for analysis of the drug in various stability samples.
    Matched MeSH terms: Ointments
  2. Patil P, Hazarey V, Chaudhari R, Nimbalkar-Patil S
    Asian Pac J Cancer Prev, 2016;17(3):1255-9.
    PMID: 27039756
    BACKGROUND: Oral physiotherapy or mouth exercise is considered to be an adjunct but mandatory treatment modality for oral submucous fibrosis (OSMF). This study planned to evaluate the clinical efficacy of a newly designed mouth exercising device (MED) in OSMF patients receiving local ointment, intra-lesional drugs and surgical treatment.

    MATERIALS AND METHODS: A total of 231 OSMF patients were selected and treated with basic regime including topical corticosteroids, oral antioxidants and the icecream-stick exercise regime and allotted randomly to two equal groups A and B. Group-A patients were additionally given MED. Subgroups A1 and B1 patients with an inter-incisal distance (IID) 20-35mm were not given any additional therapy; subgroup A2 and B2 patients (IID 20-35mm) were treated additionally with intra-lesional injections. Subgroups A3 and B3 with IID<20mm were managed surgically. IID was measured at baseline and at 6 months recall. The change in IID measurements was calculated and statistically analyzed using 2-way ANOVA and Tukeys multiple post hoc analysis.

    RESULTS: Average improvement in IID after six months of recall visits was observed to be 8.4 mm in subgroup-A1 (n-53) compared to 5.5 mm in B1(n-50) (p<0.01). The IID improvement in subgroup-A2 was found to be 9.3mm (n-46) compared to 5.1 mm in B2 (n-48) (p<0.01). In the surgery group, mouth opening improvement was observed to be 9.6 mm in subgroup A3 (n-18) compared to 4.8 mm for B3 (n-16) (p<0.01).

    CONCLUSIONS: Use of the MED appears to be effective for increasing oral opening in OMSF patients in conjunction with local, injection and/or surgical treatment.

    Matched MeSH terms: Ointments/administration & dosage*
  3. Rajan, S., Awang, H., Pooi, A.H., Hassan, H., Devi, S.
    Ann Dent, 2008;15(1):5-10.
    MyJurnal
    Objective: An in vitro assessment of MG-63 human osteosarcoma cells' alkaline phosphatase (ALP) activity when in contact with calcium hydroxide powder (CH), paste (CHP) and grey mineral trioxide aggregate (MTA). Methods: MG-63 cells were seeded to the three selected materials for durations of 0.25, 0.5, 1, 24, 48 and 72 hours. BCIP-NBT assay was used and ALP activity quantified using ELISA reader at 410 nm. Results: The overall analysis for ALP activity indicated significant interaction between test materials and control (maintenance medium). Subsequently, the test materials were paired and analysed for initial (0.25, 0.5, 1 hour) and delayed response (24, 48 and 72 hours). During the initial response, CH exhibited an increased ALP activity compared to MTA. This interaction was not dependant on duration. The delayed response exhibited elevated ALP activity with CHP when compared to MTA and CH. The interaction of CHP was dependant on duration. Conclusion: All three materials exhibited increased ALP activity.
    Matched MeSH terms: Ointments
  4. Dua K, Pabreja K, Ramana MV
    Acta Pharm, 2010 Dec;60(4):467-78.
    PMID: 21169138 DOI: 10.2478/v1007-010-0036-5
    Aceclofenac is a new generation non-steroidal anti-inflammatory drug showing effective anti-inflammatory and analgesic properties. It is available in the form of tablets of 100 mg. Importance of aceclofenac as a NSAID has inspired development of topical dosage forms. This mode of administration may help avoid typical side effects associated with oral administration of NSAIDs, which have led to its withdrawal. Furthermore, aceclofenac topical dosage forms can be used as a supplement to oral therapy for better treatment of conditions such as arthritis. Ointments, creams, and gels containing 1% (m/m) aceclofenac have been prepared. They were tested for physical appearance, pH, spreadability, extrudability, drug content uniformity, in vitro diffusion and in vitro permeation. Gels prepared using Carbopol 940 (AF2, AF3) and macrogol bases (AF7) were selected after the analysis of the results. They were evaluated for acute skin irritancy, anti-inflammatory and analgesic effects using the carrageenan-induced thermal hyperalgesia and paw edema method. AF2 was shown to be significantly (p < 0.05) more effective in inhibiting hyperalgesia associated with inflammation, compared to AF3 and AF7. Hence, AF2 may be suggested as an alternative to oral preparations.
    Matched MeSH terms: Ointments
  5. Durairaj, R., Leong, K.C., Chia Wea, L., Wong, M.C.
    ASM Science Journal, 2011;5(2):109-114.
    MyJurnal
    Lead-free solder paste printing processes account for the majority of assembly defects in the electronic manufacturing industry. In the stencil printing process, the solder paste must be able to withstand low and high shear rates which result in continuous structural breakdown and build-up. This study investigated the effect of the addition of nickel and platinum powders to the thixotropic behaviour of lead-free Sn/Ag/Cu solder pastes using the structural kinetic model. A hysteresis loop test and constant shear test were utilized to investigate the thixotropic behaviour of the pastes using parallel plate rheometry at 25ºC. In this study, the shear rates were increased from 0.01 s–1 to 10 s–1 and the second curve was a result of decreasing the shear rate from 10 s–1 to 0.01 s–1. For the constant shear test, the samples were subjected to five different shear rates of 0.01s–1, 0.1s–1, 1s–1, 10s–1 and 100s–1. The constant shear rate test was designed to study the structural breakdown and build-up of the paste materials. From this investigation, the hysteresis loop test was shown to be an effective test method to differentiate the extent of structural recovery in the solder pastes. All the pastes showed a high degree of shear thinning behaviour with time. This might be due to the agglomeration of particles in the flux that prohibited paste flow under low shear rate. The action of high shear rate would break the agglomerates into smaller pieces which facilitated the flow of pastes, thus viscosity was reduced at high shear rate.
    Matched MeSH terms: Ointments
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links