Displaying publications 41 - 58 of 58 in total

Abstract:
Sort:
  1. Ahmed HMA, Rossi-Fedele G
    Eur Endod J, 2020 12;5(3):159-176.
    PMID: 33353923 DOI: 10.14744/eej.2020.88942
    OBJECTIVE: Consistent reporting of publications in a given topic is essential. This systematic review aimed to identify and evaluate the reporting items in previous publications related to root canal anatomy in major Endodontic journals.

    METHODS: A systematic review was undertaken following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A comprehensive literature search was performed by 2 independent reviewers using a customized search strategy in major Endodontic journals through Scopus until November 2019. Studies investigating root and canal anatomy were included. The selected publications were divided into 7 categories according to the study design: micro-computed tomography (microCT) and cone-beam computed tomography (CBCT) experimental studies (extracted teeth), CBCT and 2D clinical studies, CBCT and 2D case reports in addition to others (i.e. staining and clearing method and root sectioning). The selected studies were evaluated according to three domains: 1) Criteria for study sample selection; 2) Criteria for methodological procedures and 3) Criteria for detection and evaluation.

    RESULTS: After the removal of duplicated and irrelevant papers, 137 articles were included. Results showed that microCT studies reported accurately the tooth type, number of teeth, classifications used, qualitative and/or quantitative analysis (if required) and the evaluation process. However, sample size calculation, calibration, and reproducibility were not reported in the majority of microCT studies. CBCT clinical studies presented information for the type of study, inclusion/exclusion criteria, number of patients, tooth type, and number of teeth. However, the majority did not report sample size calculation and calibration of examiners. Radiographic exposure descriptions and classifications used were not reported adequately in CBCT and 2D case reports. Sample size calculation, calibration and reproducibility were not reported in staining and clearing method.

    CONCLUSION: Despite accurate presentation of certain items, there is considerable inconsistent reporting of root and canal morphology regardless of the type of study and experimental procedure used. The PROUD checklist protocol presented in this systematic review aims to provide an accurate description of root canal anatomy in experimental, clinical, and case report publications.

    Matched MeSH terms: X-Ray Microtomography
  2. Omar FN, Hafid HS, Samsu Baharuddin A, Mohammed MAP, Abdullah J
    Planta, 2017 Sep;246(3):567-577.
    PMID: 28620814 DOI: 10.1007/s00425-017-2717-5
    MAIN CONCLUSION: X-ray microtomography results revealed that delignification process damaged the oil palm fibers, which correlated well with reduction of lignin components and increase of the phenolic content. Biodegradation investigation of natural fibers normally focuses on physico-chemical analysis, with less emphasis on physical aspect like fiber structures affect from microbial activity. In this work, the performance of Pycnoporus sanguineus to delignify oil palm empty fruit bunch fibers through solid-state fermentation utilizing various ratio of POME sludge was reported. In addition to tensile testing, physico-chemical and X-ray microtomography (µ-CT) analyses on the oil palm fibers were conducted to determine the effectiveness of the degradation process. The best ratio of fiber to fungi (60:40) was chosen based on the highest lignin loss and total phenolic content values and further investigation was performed to obtain fermentation kinetics data of both laccase and manganese peroxidase. µ-CT results revealed that delignification process damaged the pre-treated and untreated fibers structure, as evident from volume reduction after degradation process. This is correlated with reduction of lignin component and increase of the phenolic content, as well as lower stress-strain curves of the pre-treated fibers compared to the untreated ones (from tensile testing). It is suggested that P. sanguineus preferred to consume the outer layer of the fiber, before it penetrates through the cellular structure of the inner fiber.
    Matched MeSH terms: X-Ray Microtomography
  3. Luchman NA, Megat Abdul Wahab R, Zainal Ariffin SH, Nasruddin NS, Lau SF, Yazid F
    PeerJ, 2022;10:e13356.
    PMID: 35529494 DOI: 10.7717/peerj.13356
    BACKGROUND: The selection of appropriate scaffold plays an important role in ensuring the success of bone regeneration. The use of scaffolds with different materials and their effect on the osteogenic performance of cells is not well studied and this can affect the selection of suitable scaffolds for transplantation. Hence, this study aimed to investigate the comparative ability of two different synthetic scaffolds, mainly hydroxyapatite (HA) and polycaprolactone (PCL) scaffolds in promoting in vitro and in vivo bone regeneration.

    METHOD: In vitro cell viability, morphology, and alkaline phosphatase (ALP) activity of MC3T3-E1 cells on HA and PCL scaffolds were determined in comparison to the accepted model outlined for two-dimensional systems. An in vivo study involving the transplantation of MC3T3-E1 cells with scaffolds into an artificial bone defect of 4 mm length and 1.5 mm depth in the rat's left maxilla was conducted. Three-dimensional analysis using micro-computed tomography (micro-CT), hematoxylin and eosin (H&E), and immunohistochemistry analyses evaluation were performed after six weeks of transplantation.

    RESULTS: MC3T3-E1 cells on the HA scaffold showed the highest cell viability. The cell viability on both scaffolds decreased after 14 days of culture, which reflects the dominant occurrence of osteoblast differentiation. An early sign of osteoblast differentiation can be detected on the PCL scaffold. However, cells on the HA scaffold showed more prominent results with intense mineralized nodules and significantly (p 

    Matched MeSH terms: X-Ray Microtomography
  4. Al-Rammahi HM, Chai WL, Nabhan MS, Ahmed HMA
    BMC Oral Health, 2023 May 29;23(1):339.
    PMID: 37248469 DOI: 10.1186/s12903-023-03036-5
    BACKGROUND: A thorough understanding of root and canal anatomy is crucial for successful root canal treatment outcomes. This systematic review aims to explore the published micro-CT studies investigated the anatomy of root and canal system in permanent mandibular first molars.

    METHOD: An electronic search was performed on Web of science, PubMed, and Scopus. Micro-CT journal studies investigated the root and canal anatomy of permanent double-rooted mandibular first molars were included. Data on study characteristics, objectives of interest, specifications of the studies, and micro-CT specifications were extracted. Risk of bias assessment (ROB) of the included studies was performed using Anatomical Quality Assessment (AQUA) tool. The extracted data were presented in tables and figures to present and synthesise the results. A meta-analysis was performed for the studies related to the prevalence of Vertucci's canal configurations, middle mesial canal (MMC) configurations, and Fan's isthmus types.

    RESULTS: Amongst 1358 identified studies, thirty met the inclusion criteria. In terms of the objectives, the selected studies showed high anatomical variability in mandibular first molars. Twenty-two (73%), 25 (83%), and 12 (40%) of the studies reported the population/ethnicity, micro-CT specifications, and ethical approval, respectively. 28 (93%) studies did not disclose the method of sample size estimation. In only 6 (20%) of the studies, the authors had calibrated the assessment approaches. Mostly, a potential ROB was reported in domain 1 (objective(s) and subject characteristics) and domain 3 (methodology characterization). Whilst, low risk was reported in domains 2 (study design), 4 (descriptive anatomy), and 5 (reporting of results). The overall ROB was reported to be ''moderate'' in the vast majority of the studies (27/30). Meta-analysis results showed high levels of heterogeneity among the studies related to MMCs (I2 = 86%) and Fan's isthmus (I2 = 87%). As for the root canal configuration, pooled prevalence showed that Vertucci type IV and type I were the most prevalent in mesial and distal root canals, respectively.

    CONCLUSION: Based on moderate risk of bias level of evidence, micro-CT studies have shown wide range of qualitative and quantitative data presentations of the roots and canals in mandibular first molars. Protocol and registration. The protocol of this systematic review was prospectively registered in the Open Science Framework database ( https://osf.io ) on 2022-06-20 with the registration number 10.17605/OSF.IO/EZP7K.

    Matched MeSH terms: X-Ray Microtomography
  5. Mustafa M, Batul R, Karobari MI, Alamri HM, Abdulwahed A, Almokhatieb AA, et al.
    BMC Oral Health, 2024 Mar 16;24(1):343.
    PMID: 38493123 DOI: 10.1186/s12903-024-04101-3
    INTRODUCTION: Root canal treatment procedures require a thorough understanding of root and canal anatomy. The purpose of this systematic review was to examine the morphological differences of teeth root and their canals assessed using cone-beam computed and micro-computed tomography in Saudi Arabian population.

    METHODOLOGY: An electronic search was conducted in PubMed / Medline, Scopus, Google Scholar, and Web of Science databases until January 2023 to retrieve related studies. "Root canal morphology," "Saudi Arabia," "Micro-CT," and "cone-beam computed tomography" were used as keywords. A modified version of previously published risk of bias assessment tool was used to determine the quality assessment of included studies.

    RESULTS: The literature search revealed 47 studies that matched the criteria for inclusion, out of which 44 studies used cone beam computed tomography (CBCT) and three were micro-computed tomography (micro-CT) studies. According to the modified version of risk of bias assessment tool, the studies were categorized as low, moderate, and high risk of bias. A total of 47,612 samples were included which comprised of either maxillary teeth (5,412), or mandibular teeth (20,572), and mixed teeth (21,327). 265 samples were used in micro-CT studies while 47,347 teeth samples were used in CBCT studies. Among the CBCT studies, except for three, all the studies were retrospective studies. Frequently used imaging machine and software were 3D Accuitomo 170 and Morita's i-Dixel 3D imaging software respectively. Minimum and maximum voxel sizes were 75 and 300 μm, Vertucci's classification was mostly used to classify the root canal morphology of the teeth. The included micro-CT studies were in-vitro studies where SkyScan 1172 X-ray scanner was the imaging machine with pixel size ranging between 13.4 and 27.4 μm. Vertucci, Ahmed et al. and Pomeranz et al. classifications were applied to classify the root canal morphology.

    CONCLUSION: This systematic review revealed wide variations in root and canal morphology of Saudi population using high resolution imaging techniques. Clinicians should be aware of the common and unusual root and canal anatomy before commencing root canal treatment. Future micro-CT studies are needed to provide additional qualitative and quantitative data presentations.

    Matched MeSH terms: X-Ray Microtomography
  6. Alavi R, Akbarzadeh AH, Hermawan H
    J Mech Behav Biomed Mater, 2021 05;117:104413.
    PMID: 33640846 DOI: 10.1016/j.jmbbm.2021.104413
    In-depth analyses of post-corrosion mechanical properties and architecture of open cell iron foams with hollow struts as absorbable bone scaffolds were carried out. Variations in the architectural features of the foams after 14 days of immersion in a Hanks' solution were investigated using micro-computed tomography and scanning electron microscope images. Finite element Kelvin foam model was developed, and the numerical modeling and experimental results were compared against each other. It was observed that the iron foam samples were mostly corroded in the periphery regions. Except for quasi-elastic gradient, other mechanical properties (i.e. compressive strength, yield strength and energy absorbability) decreased monotonically with immersion time. Presence of adherent corrosion products enhanced the load-bearing capacity of the open cell iron foams at small strains. The finite element prediction for the quasi-elastic response of the 14-day corroded foam was in an agreement with the experimental results. This study highlights the importance of considering corrosion mechanism when designing absorbable scaffolds; this is indispensable to offer desirable mechanical properties in porous materials during degradation in a biological environment.
    Matched MeSH terms: X-Ray Microtomography
  7. Khan AS, Ur Rehman S, Ahmad S, AlMaimouni YK, Alzamil MAS, Dummer PMH
    Int Endod J, 2021 Oct;54(10):1819-1839.
    PMID: 34196006 DOI: 10.1111/iej.13595
    AIM: The International Endodontic Journal (IEJ) has served as a platform for research and clinical practice in Endodontics since 1967. This study provides a bibliographic analysis and overview of the publications that have appeared in the IEJ from 1967 to 2020.

    METHODOLOGY: A literature search was performed in Elsevier's Scopus database to locate all the publications of the International Endodontic Journal. Various bibliometric software packages including the open-source visualization software Gephi and Biblioshiny (version 2.0) were employed for data visualization and analysis.

    RESULTS: A total of 3739 records with citation and bibliographic details were selected and retrieved to allow a bibliometric analysis to be performed. The bibliometric analysis indicates that the IEJ has grown both in terms of productivity and influence. Over time, the journal has been associated with an increase in the number of manuscripts published and the citations they have attracted, but with minor downward fluctuations in citations in the last few years. Bibliographic coupling of the IEJ articles revealed that the major research themes published in the journal include 'endodontics', 'root canal treatment', 'calcium hydroxide', 'apical periodontitis', 'mineral trioxide aggregate', 'microbiology', 'cyclic fatigue', 'cone-beam computed tomography' and 'micro-computed tomography'. Authors affiliated to institutions in the UK were the major contributors to the journal and were linked with other countries such as Brazil, USA and Malaysia. The largest number of publications were from the University of São Paulo, Brazil.

    CONCLUSION: The IEJ is one of the leading journals in Endodontology and has been providing a platform for innovative research and clinical reports for more than 50 years. Publications have been associated with a wide range of authors, institutions and countries around the world.

    Matched MeSH terms: X-Ray Microtomography
  8. Goh CF, O'Flynn D, Speller R, Lane ME
    Micron, 2021 06;145:103045.
    PMID: 33689970 DOI: 10.1016/j.micron.2021.103045
    Drug crystallisation in the skin is recognised as a significant problem in topical and transdermal drug delivery. Our recent investigations provided new evidence of drug crystallisation in the skin, however, confirming the precise location of crystals remains challenging. Of note, most approaches used have required disruption of the membrane by tape stripping, with crystal detection limited to the superficial skin layers. Hence, a non-destructive method for complete spatial resolution of crystallised drug in skin is still lacking. In this communication, we report the application of X-ray micro-computed tomography (microCT) to examine drug crystallisation in mammalian skin ex vivo. Permeation studies of a saturated solution of diclofenac sodium were conducted in porcine skin; subsequently, tissue samples were scanned using microCT to generate 2D and 3D maps. A layer of drug crystals was observed on the skin surface; microCT maps also confirmed the distribution of drug crystals up to a skin depth of 0.2 - 0.3 mm. MicroCT also allowed the identification of drug crystallisation as a distinct and confirmed event in the skin and as an extension from drug crystals formed on the skin. These preliminary results confirm the potential of microCT to study this important phenomenon in topical and transdermal drug delivery.
    Matched MeSH terms: X-Ray Microtomography
  9. Sulaiman SZS, Tan WM, Radzi R, Shafie INF, Ajat M, Mansor R, et al.
    J Orthop Surg Res, 2021 Nov 08;16(1):663.
    PMID: 34749769 DOI: 10.1186/s13018-021-02781-z
    BACKGROUND: Osteoarthritis (OA) is a multifaceted condition that affects both the subchondral bones and the articular cartilage. Animal models are widely used as an effective supplement and simulation for human OA studies in investigating disease mechanisms and pathophysiology. This study is aimed to evaluate the temporal changes of bone and cartilage in surgically and chemically induced osteoarthritis using micro-computed tomography and histology.

    METHODS: Thirty rabbits underwent either anterior cruciate ligament transection (ACLT) procedure or injected intraarticularly with monosodium iodoacetate (MIA, 8 mg) at the right knee joint. The subchondral bones were scanned via micro-CT, and articular cartilage was assessed histologically at 4-, 8- and 12-week post-induction.

    RESULTS: Based on bone micro-architecture parameters, the surgically induced group revealed bone remodelling processes, indicated by increase bone volume, thickening of trabeculae, reduced trabecular separation and reduced porosity. On the other hand, the chemically induced group showed active bone resorption processes depicted by decrease bone volume, thinning of trabeculae, increased separation of trabecular and increased porosity consistently until week 12. Histologically, the chemically induced group showed more severe articular cartilage damage compared to the surgically induced group.

    CONCLUSIONS: It can be concluded that in the ACLT group, subchondral bone remodelling precedes articular cartilage damage and vice versa in the MIA group. The findings revealed distinct pathogenic pathways for both induction methods, providing insight into tailored therapeutic strategies, as well as disease progression and treatment outcomes monitoring.

    Matched MeSH terms: X-Ray Microtomography
  10. Karobari MI, Batul R, Khan M, Patil SR, Basheer SN, Rezallah NNF, et al.
    BMC Oral Health, 2024 Jan 02;24(1):1.
    PMID: 38167114 DOI: 10.1186/s12903-023-03624-5
    INTRODUCTION: Mandibular first premolars are familiar with their varied root canal morphology, causing difficulties and challenges for successful endodontic procedures. This systematic review and meta-analysis aim to study the characterization of root and canal morphology of the first mandibular premolar using micro-computed tomography.

    METHODOLOGY: The literature search was conducted using electronic web databases like PubMed, Scopus, ScienceDirect and Cochrane with the chosen MeSH key words and data was retrieved until May 2023. Further to perform the statistical analysis, R v 4.3.1 software with "meta", 'metafor" "metaviz" " ggplot2" package was used, and results were represented by odds ratios (OR) and the percentage of forest plots along a 95 per cent confidence interval (CI).

    RESULTS: The total number of studies meeting the inclusion criteria was 13; these studies were conducted on mandibular first premolar using Micro-CT; the total sample size was 1817. To scan the sample, an X-ray micro-focus CT system (Siemens Inveon CT, Erlangen, Germany) was used in four studies and seven different machines were used in the respective studies. Mimics 10.01 software (Materialize, Leuven, Belgium) and NRecon v.1.6.9 software (Bruker, Kontich, Belgium) were commonly operated. The minimum and maximum voxel size ranges between 11.94 and 50 μm. Vertucci's classification was frequently used (9), while one study applied Ahmed et al. and Vertucci's classification.

    CONCLUSION: This systematic review provides essential information about the root and canal configurations, radicular grooves, accessory canals, and apical foramina through Micro-CT, aiming to improve the accuracy of endodontic treatment and help practitioners.

    Matched MeSH terms: X-Ray Microtomography
  11. Effendy NM, Khamis MF, Shuid AN
    Curr Drug Targets, 2013 Dec;14(13):1542-51.
    PMID: 24010967
    Bone quality assessment is important in assessments of potential agents for the prevention and treatment of osteoporosis. Bone density, microarchitecture and strength are important determinants in osteoporotic study which are widely studied using Dual-Energy X-ray Absorptiometry (DXA), histomorphometry and radiological imaging techniques. In recent years, high resolution micro-CT has become feasible for in vitro or in vivo evaluation of bone architecture. Three-dimensional images of micro-CT reflected high correlations with the conventional histomorphometry and DXA. In comparison to other imaging techniques, micro-CT is the most effective tool in detecting early bone changes for fracture prediction and assessments of potential anti-osteoporotic agents. It is crucial to define an ideal setting with safe radiation doses and appropriate methods for image reconstruction and segmentation to obtain high resolution images. Micro-CT evaluation provides a better insight of bone structure as well as non-metric parameters such as connectivity density, structural model index (SMI) and degree of anisotropy (DA). This non- invasive imaging technique is also equipped with finite element analysis for evaluation of bone biomechanical strength. Micro-CT allows a compressive understanding of the relationships between bone density, microarchitecture and strength which is fundamental to development of pharmacological interventions.
    Matched MeSH terms: X-Ray Microtomography*
  12. Ahmed HM, Khamis MF, Gutmann JL
    Scanning, 2016 Nov;38(6):554-557.
    PMID: 26751249 DOI: 10.1002/sca.21299
    The root and root canal morphology of deciduous molars shows considerable variations. Consequently, a comprehensive understanding of the normal and unusual root and root canal configuration types in deciduous teeth is of prime importance. The purpose of this report is to describe a rare anatomical variation in a double-rooted maxillary deciduous molar examined by the dental operating microscope and micro-computed tomography. SCANNING 38:554-557, 2016. © 2016 Wiley Periodicals, Inc.
    Matched MeSH terms: X-Ray Microtomography/methods*
  13. Ibrahim N, Parsa A, Hassan B, van der Stelt P, Rahmat RA, Ismail SM, et al.
    BMC Oral Health, 2021 05 08;21(1):249.
    PMID: 33964918 DOI: 10.1186/s12903-021-01595-z
    BACKGROUND: The aim of this study was to compare the trabecular bone microstructures of anterior and posterior edentulous regions of human mandible using cone-beam computed tomography (CBCT) and micro computed tomography (µCT).

    METHODS: Twenty volumes of interests consisting of six anterior and fourteen posterior edentulous regions were obtained from human mandibular cadavers. A CBCT system with a resolution of 80 µm (3D Accuitomo 170, J. Morita, Kyoto, Japan) and a µCT system with a resolution of 35 µm (SkyScan 1173, Kontich, Belgium) were used to scan the mandibles. Three structural parameters namely, trabecular number (Tb.N), trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp) were analysed using CTAn software (v 1.11, SkyScan, Kontich, Belgium). For each system, the measurements obtained from anterior and posterior regions were tested using independent sample t-test. Subsequently, all measurements between systems were tested using paired t-test.

    RESULTS: In CBCT, all parameters of the anterior and posterior mandible showed no significant differences (p > 0.05). However, µCT showed a significant different of Tb.Th (p = 0.023) between anterior and posterior region. Regardless of regions, the measurements obtained using both imaging systems were significantly different (p ≤ 0.021) for Tb.Th and Tb.N.

    CONCLUSIONS: The current study demonstrated that only the variation of Tb.Th between anterior and posterior edentulous region of mandible can be detected using µCT. In addition, CBCT is less feasible than µCT in assessing trabecular bone microstructures at both regions.

    Matched MeSH terms: X-Ray Microtomography
  14. Nur Aliah NA, Heo CC, Noor Shafini M, Mohd Hafizi M
    Trop Biomed, 2019 Sep 01;36(3):640-653.
    PMID: 33597486
    Accurate estimation of the minimum post-mortem interval (minPMI) is important in the investigation of forensic cases. Various thanatological methods are being used to estimate this interval. However, entomology approach is the most reliable method for this minPMI estimation especially when death has occurred over 72 hours and involved insects or other arthropods evidence at the death scene. The current methods of age estimation are daunting and destructive especially when dealing with pupal stage. The aims of this study were to characterize the morphological changes during intra-puparial period of Chrysomya megacephala (Fabricius) (Diptera: Calliphoridae) and their relation with minPMI estimation by using a high resolution micro-Computed Tomography (micro-CT). Gravid C. megacephala were collected from a rural area in Sungai Buloh, Selangor and cultured in the laboratory at 23.83±0.25°C with light: dark hour of 12:12 to initiate oviposition. The resulting larvae were reared until pupal stage. A pupa was collected at first (24 hours), second (48 hours), third (72 hours), and fourth quarter (96 hours) of the intra-puparial period. The pupal samples were placed directly into 70% ethanol for preservation. Micro-CT scanning was employed to acquire microstructural information following pupal sample staining for contrast enhancement. Eight age-informative internal morphological landmarks were mapped from the micro-CT scanning. The present study enhanced the potential value of micro-CT for the estimation of minPMI based on the internal morphological changes of C. megacephala pupae. This novel method is a promising tool for improving medico-legal investigations in forensic entomology.
    Matched MeSH terms: X-Ray Microtomography
  15. Kamimura Y, Lee CY
    PLoS One, 2023;18(11):e0293701.
    PMID: 37917643 DOI: 10.1371/journal.pone.0293701
    Many animals take advantage of the shaded, humid, and protected environments in subcortical spaces, i.e., thin spaces under the loosened bark of dead trees. Permanent inhabitants of subcortical spaces often show specialized morphologies, such as a miniaturized or dorsoventrally flattened body. However, the evolutionary consequences of these specialized morphologies on behavioral, ecological, and life-history traits have been little studied. We studied the mating biology and anatomy of Platylabia major (usually placed in the family Anisolabididae), which is an obligate inhabitant of subcortical spaces with a paper-like flattened body, and compared them with those of two thicker, spongiphorid earwigs, Nesogaster amoenus and Paralabellula curvicauda. Mating trials in various settings showed that Pl. major requires thin spaces sandwiched by two planes to accomplish genital coupling and insemination. In contrast, the thicker species, although also frequently found in subcortical spaces, could mate on a single horizontal plane due to the ability of the male to twist its abdomen through approximately 180°. Examination by micro-computed tomography and a reagent-based clearing technique revealed no substantive differences in the configuration of mid-abdominal musculature between the species. The dorsal and lateral muscles of Pl. major, which are almost parallel to the antero-posterior body axis for accommodation within the thin abdomen, seemed incapable of producing the power to twist the abdomen. The abdominal musculature conforms to a simple pattern in both male and female earwigs, which is repeated in each of the pregenital segments. We conclude that small differences in the range of motion of each abdominal segment can result in large differences in possible mating postures and positions. Surgical experiments also demonstrated that both right and left penises of Pl. major are competent and used for insemination with no lateral bias, as in most other earwigs with twin penises studied to date.
    Matched MeSH terms: X-Ray Microtomography
  16. Alyessary AS, Yap AUJ, Othman SA, Ibrahim N, Rahman MT, Radzi Z
    Am J Orthod Dentofacial Orthop, 2018 Aug;154(2):260-269.
    PMID: 30075928 DOI: 10.1016/j.ajodo.2017.11.031
    INTRODUCTION: In this study, we evaluated the effect of bone-borne accelerated expansion protocols on sutural separation and sutural bone modeling using a microcomputed tomography system. We also determined the optimum instant sutural expansion possible without disruption of bone modeling.

    METHODS: Sixteen New Zealand white rabbits, 20 to 24 weeks old, were randomly divided into 4 experimental groups. Modified hyrax expanders were placed across their interfrontal sutures and secured with miniscrew implants located bilaterally in the frontal bone. The hyrax appliances were activated as follows: group 1 (control), 0.5-mm per day expansion for 12 days; group 2, 1-mm instant expansion followed by 0.5 mm per day for 10 days; group 3, 2.5-mm instant expansion followed by 0.5 mm per day for 7 days, and group 4, 4-mm instant expansion followed by 0.5 mm per day for 4 days. After 6 weeks of retention, sutural separation and sutural bone modeling were assessed by microcomputed tomography and quantified. Statistical analysis was performed using Kruskal Wallis and Mann-Whitney U tests and the Spearman rho correlation (P <0.05).

    RESULTS: Median amounts of sutural separation ranged from 2.84 to 4.41 mm for groups 1 and 4, respectively. Median bone volume fraction ranged from 59.96% to 69.15% for groups 4 and 3, respectively. A significant correlation (r = 0.970; P <0.01) was observed between the amounts of instant expansion and sutural separation.

    CONCLUSIONS: Pending histologic verifications, our findings suggest that the protocol involving 2.5 mm of instant expansion followed by 0.5 mm per day for 7 days is optimal for accelerated sutural expansion. When 4 mm of instant expansion was used, the sutural bone volume fraction was decreased.

    Matched MeSH terms: X-Ray Microtomography*
  17. Arumugam S, Yew HZ, Baharin SA, Qamaruz Zaman J, Muchtar A, Kanagasingam S
    Aust Endod J, 2021 Dec;47(3):520-530.
    PMID: 33956372 DOI: 10.1111/aej.12516
    This study aimed to evaluate and compare the frequency of microcracks and its severity at different root canal dentin locations, after preparation with thermomechanically heat-treated engine-driven nickel-titanium instruments. Forty mandibular premolars were assigned to four experimental groups (n = 10): ProTaper Next, ProTaper Gold, WaveOne Gold and Reciproc Blue. After pre-instrumentation micro-computed tomography scans, the root canals were prepared to size 25. Following post-instrumentation scans, pre- and post-instrumentation scanned images were analysed for the presence and extent of dentinal defects. A total of 56 500 cross-sectional images were obtained, showing that less than 2.3% with pre-existing dentinal microcracks. No new microcracks were identified during the post-instrumentation analyses. No significant association was found between the types of dentinal defects, file motions and sequences. Thermomechanically heat-treated rotary files did not induce the formation of new microcracks. There was also no association between the kinematic motions and sequences of the rotary instruments to the types of dentinal defects.
    Matched MeSH terms: X-Ray Microtomography
  18. Zainuddin MZ, Mohamad NS, Su Keng T, Mohd Yusof MYP
    J Forensic Sci, 2023 Nov;68(6):2048-2056.
    PMID: 37529884 DOI: 10.1111/1556-4029.15352
    Conventional dental age estimation relies on destructive methods such as sectioning and staining, which are unpreferable when the tooth is required for evidential or archeological preservation. MicroCT is a non-destructive, high-resolution imaging technique that allows for accurate morphometrical measurement. Although microCT technology has been applied in a variety of dental studies, studies focusing on dental age-related change and dental age estimation based on microCT imaging remain lacking. Based on the question: "How has microCT technology been applied in studying human age-related tooth morphological change and dental age estimation studies?", the authors conducted a scoping review in accordance with the Arksey and O'Malley (2005) and the PRISMA-ScR guidelines. A literature search using five major scientific databases identified 452 articles, with 11 full-text articles being eligible to be included in the scoping review. Furthermore, 6 out of the 11 studies performed dental age estimation modeling. An overview of the parameters used in the selected articles revealed a variety of tooth characteristics, such as pulp cavity to whole tooth volume ratio, secondary dentin, as well as the diameter of root canal orifice. The findings of this scoping review highlight the extent microCT is used in studying dental age-related changes, as well as the effectiveness of microCT in dental age estimation studies. This review serves as a guide for future forensic odontology age estimation studies.
    Matched MeSH terms: X-Ray Microtomography/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links