Displaying publications 61 - 80 of 116 in total

Abstract:
Sort:
  1. Khalaj N, Abu Osman NA, Mokhtar AH, Mehdikhani M, Wan Abas WA
    PLoS One, 2014;9(3):e92270.
    PMID: 24642715 DOI: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC39584
    Balance is essential for mobility and performing activities of daily living. People with knee osteoarthritis display impairment in knee joint proprioception. Thus, the aim of this study was to evaluate balance and risk of fall in individuals with bilateral mild and moderate knee osteoarthritis. Sixty subjects aged between 50 and 70 years volunteered in this study. They were categorized into three groups which were healthy (n = 20), mild (n = 20) and moderate (n = 20) bilateral knee osteoarthritis groups. Dynamic and static balance and risk of fall were assessed using Biodex Stability System. In addition, Timed Up and Go test was used as a clinical test for balance. Results of this study illustrated that there were significant differences in balance (dynamic and static) and risk of fall between three groups. In addition, the main (most significant) difference was found to be between healthy group and moderate group. Furthermore, on clinical scoring of balance, the "Timed Up and Go" test, all three groups showed significant difference. In conclusion, bilateral knee osteoarthritis impaired the balance and increased the risk of fall, particularly in people with moderate knee osteoarthritis.
  2. Das NS, Usman J, Choudhury D, Abu Osman NA
    PLoS One, 2014;9(6):e100028.
    PMID: 24927127 DOI: 10.1371/journal.pone.0100028
    Cricket has over the years gained much popularity in Asia, thus the number of cricket players has also grown in tandem. However, cricket players are not as fortunate as other athletes as they do not always have a standard cricket infrastructure to practice; therefore, the injury prevalence is expected to be high. Unfortunately, very few studies have been conducted to investigate the nature and pattern of cricket injuries prevalent to cricketers in this region. Therefore, a prospective cohort injury surveillance study was conducted during the Asian Cricket Council (ACC) Under-19 Elite Cup held in June 2013 in order to gather more data on the type of injuries sustained by cricket players. Overall, 31 injuries occurred to 28 players throughout the tournament, of which 7 injuries happened during practice sessions. The overall injury incidence rate (IIR) was 292.0 per 10,000 player hours (95% CI 176.9-407.1) and 10.4 per 10,000 balls faced and 2.6 per 1000 overs bowled delivered during batting and bowling, respectively. Injuries to the lower limb (IIR: 146; 95% CI 1.8-98.2) were the most frequent, followed by injuries to the upper limb (97.3;95% CI 30.2-164.5) and to the trunk and back (IIR: 36.5;95% CI 0.0-77.7). Sprain/strains (IIR 109.5;95% CI 38.4-180.7) to muscle/tendon and joint/ligament were the most commonly reported nature of injury. This is the first study investigating injury incidence among the players of the ACC. It provides an overview of injuries sustained by elite players' under-19 years of age from 10 Asian countries. The overall IIR is similar to earlier studies conducted in well-established cricket playing nations.
  3. Eshraghi A, Abu Osman NA, Karimi M, Gholizadeh H, Soodmand E, Wan Abas WA
    PLoS One, 2014;9(5):e96988.
    PMID: 24865351 DOI: 10.1371/journal.pone.0096988
    Prosthetic suspension system is an important component of lower limb prostheses. Suspension efficiency can be best evaluated during one of the vital activities of daily living, i.e. walking. A new magnetic prosthetic suspension system has been developed, but its effects on gait biomechanics have not been studied. This study aimed to explore the effect of suspension type on kinetic and kinematic gait parameters during level walking with the new suspension system as well as two other commonly used systems (the Seal-In and pin/lock). Thirteen persons with transtibial amputation participated in this study. A Vicon motion system (six cameras, two force platforms) was utilized to obtain gait kinetic and kinematic variables, as well as pistoning within the prosthetic socket. The gait deviation index was also calculated based on the kinematic data. The findings indicated significant difference in the pistoning values among the three suspension systems. The Seal-In system resulted in the least pistoning compared with the other two systems. Several kinetic and kinematic variables were also affected by the suspension type. The ground reaction force data showed that lower load was applied to the limb joints with the magnetic suspension system compared with the pin/lock suspension. The gait deviation index showed significant deviation from the normal with all the systems, but the systems did not differ significantly. Main significant effects of the suspension type were seen in the GRF (vertical and fore-aft), knee and ankle angles. The new magnetic suspension system showed comparable effects in the remaining kinetic and kinematic gait parameters to the other studied systems. This study may have implications on the selection of suspension systems for transtibial prostheses. Trial registration: Iranian Registry of Clinical Trials IRCT2013061813706N1.
  4. Arifin N, Abu Osman NA, Ali S, Wan Abas WA
    Biomed Eng Online, 2014;13(1):23.
    PMID: 24597518 DOI: 10.1186/1475-925X-13-23
    Achieving independent upright posture has known to be one of the main goals in rehabilitation following lower limb amputation. The purpose of this study was to compare postural steadiness of below knee amputees with visual alterations while wearing three different prosthetic feet.
  5. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Arifin N, Wan Abas WA
    Biomed Eng Online, 2014;13:1.
    PMID: 24410918 DOI: 10.1186/1475-925X-13-1
    Good prosthetic suspension system secures the residual limb inside the prosthetic socket and enables easy donning and doffing. This study aimed to introduce, evaluate and compare a newly designed prosthetic suspension system (HOLO) with the current suspension systems (suction, pin/lock and magnetic systems).
  6. Abd Razak NA, Abu Osman NA, Gholizadeh H, Ali S
    Biomed Eng Online, 2014;13:134.
    PMID: 25208636 DOI: 10.1186/1475-925X-13-134
    Understanding of kinematics force applied at the elbow is important in many fields, including biomechanics, biomedical engineering and rehabilitation. This paper provides a comparison of a mathematical model of elbow joint using three different types of prosthetics for transhumeral user, and characterizes the forces required to overcome the passive mechanical of the prosthetics at the residual limb.
  7. Eshraghi A, Abu Osman NA, Gholizadeh H, Ali S, Abas WA
    Am J Phys Med Rehabil, 2015 Jan;94(1):1-10.
    PMID: 24919079 DOI: 10.1097/PHM.0000000000000134
    This study aimed to compare the effects of different suspension methods on the interface stress inside the prosthetic sockets of transtibial amputees when negotiating ramps and stairs.
  8. Oshkour AA, Talebi H, Seyed Shirazi SF, Yau YH, Tarlochan F, Abu Osman NA
    Artif Organs, 2015 Feb;39(2):156-64.
    PMID: 24841371 DOI: 10.1111/aor.12315
    This study aimed to assess the performance of different longitudinal functionally graded femoral prostheses. This study was also designed to develop an appropriate prosthetic geometric design for longitudinal functionally graded materials. Three-dimensional models of the femur and prostheses were developed and analyzed. The elastic modulus of these prostheses in the sagittal plane was adjusted along a gradient direction from the distal end to the proximal end. Furthermore, these prostheses were composed of titanium alloy and hydroxyapatite. Results revealed that strain energy, interface stress, and developed stress in the femoral prosthesis and the bone were influenced by prosthetic geometry and gradient index. In all of the prostheses with different geometries, strain energy increased as gradient index increased. Interface stress and developed stress decreased. The minimum principal stress and the maximum principal stress of the bone slightly increased as gradient index increased. Hence, the combination of the femoral prosthetic geometry and functionally graded materials can be employed to decrease stress shielding. Such a combination can also be utilized to achieve equilibrium in terms of the stress applied on the implanted femur constituents; thus, the lifespan of total hip replacement can be prolonged.
  9. Ali Akbari Ghavimi S, Ebrahimzadeh MH, Solati-Hashjin M, Abu Osman NA
    J Biomed Mater Res A, 2015 Jul;103(7):2482-98.
    PMID: 25407786 DOI: 10.1002/jbm.a.35371
    Interests in the use of biodegradable polymers as biomaterials have grown. Among the different polymeric composites currently available, the blend of starch and polycaprolactone (PCL) has received the most attention since the 1980s. Novamont is the first company that manufactured a PCL/starch (SPCL) composite under the trademark Mater-Bi®. The properties of PCL (a synthetic, hydrophobic, flexible, expensive polymer with a low degradation rate) and starch (a natural, hydrophilic, stiff, abundant polymer with a high degradation rate) blends are interesting because of the composite components have completely different structures and characteristics. PCL can adjust humidity sensitivity of starch as a biomaterial; while starch can enhance the low biodegradation rate of PCL. Thus, by appropriate blending, SPCL can overcome important limitations of both PCL and starch components and promote controllable behavior in terms of mechanical properties and degradation which make it suitable for many biomedical applications. This article reviewed the different fabrication and modification methods of the SPCL composite; different properties such as structural, physical, and chemical as well as degradation behavior; and different applications as biomaterials.
  10. Ataollahi F, Pramanik S, Moradi A, Dalilottojari A, Pingguan-Murphy B, Wan Abas WA, et al.
    J Biomed Mater Res A, 2015 Jul;103(7):2203-13.
    PMID: 24733741 DOI: 10.1002/jbm.a.35186
    Extracellular environments can regulate cell behavior because cells can actively sense their mechanical environments. This study evaluated the adhesion, proliferation and morphology of endothelial cells on polydimethylsiloxane (PDMS)/alumina (Al2 O3 ) composites and pure PDMS. The substrates were prepared from pure PDMS and its composites with 2.5, 5, 7.5, and 10 wt % Al2 O3 at a curing temperature of 50°C for 4 h. The substrates were then characterized by mechanical, structural, and morphological analyses. The cell adhesion, proliferation, and morphology of cultured bovine aortic endothelial (BAEC) cells on substrate materials were evaluated by using resazurin assay and 1,1'-dioctadecyl-1,3,3,3',3'-tetramethylindocarbocyanine perchlorate-acetylated LDL (Dil-Ac-LDL) cell staining, respectively. The composites (PDMS/2.5, 5, 7.5, and 10 wt % Al2 O3 ) exhibited higher stiffness than the pure PDMS substrate. The results also revealed that stiffer substrates promoted endothelial cell adhesion and proliferation and also induced spread morphology in the endothelial cells compared with lesser stiff substrates. Statistical analysis showed that the effect of time on cell proliferation depended on stiffness. Therefore, this study concludes that the addition of different Al2 O3 percentages to PDMS elevated substrate stiffness which in turn increased endothelial cell adhesion and proliferation significantly and induced spindle shape morphology in endothelial cells.
  11. Arifin N, Abu Osman NA, Ali S, Gholizadeh H, Wan Abas WA
    Proc Inst Mech Eng H, 2015 Jul;229(7):491-8.
    PMID: 26019139 DOI: 10.1177/0954411915587595
    In recent years, computerized posturography has become an essential tool in quantitative assessment of postural steadiness in the clinical settings. The purpose of this study was to explore the ability of the Biodex(®) Stability System (BSS) to quantify postural steadiness in below-knee amputees. A convenience sample of 10 below-knee amputees participated in the study. The overall (OSI), anterior-posterior (APSI) and medial-lateral (MLSI) stability indexes as well as the percentage of time spent in left and right quadrants and four concentric zones were measured under altered sensory conditions while standing with solid ankle cushion heel (SACH), single-axis (SA) and energy storage and release (ESAR) feet. Significant difference was found between sensory conditions in SACH and ESAR feet for OSI (SACH, p = 0.002; ESAR, p = 0.005), APSI (SACH, p = 0.036; ESAR, p = 0.003) and MLSI (SACH, p = 0.008; ESAR, p = 0.05) stability indexes. The percentage of time spent in Zone A (0°-5°) was significantly greater than the other three concentric zones (p < 0.01). The loading time percentage on their intact limb (80%-94%) was significantly longer than the amputated limb (20%-6%) in all conditions for all three prosthetic feet. Below-knee amputees showed compromised postural steadiness when visual, proprioceptive or vestibular sensory input was altered. The findings highlight that the characteristics of postural stability in amputees can be clinically assessed by utilizing the outcomes produced by the BSS.
  12. Choudhury D, Ay Ching H, Mamat AB, Cizek J, Abu Osman NA, Vrbka M, et al.
    J Biomed Mater Res B Appl Biomater, 2015 Jul;103(5):1002-12.
    PMID: 25220737 DOI: 10.1002/jbm.b.33274
    Diamond like carbon (DLC) is applied as a thin film onto substrates to obtain desired surface properties such as increased hardness and corrosion resistance, and decreased friction and wear rate. Microdimple is an advanced surface modification technique enhancing the tribological performance. In this study, DLC coated microdimples were fabricated on hip prosthesis heads and their mechanical, material and surface properties were characterized. An Electro discharge machining (EDM) oriented microdrilling was utilized to fabricate a defined microdimple array (diameter of 300 µm, depth of 70 µm, and pitch of 900 µm) on stainless steel (SS) hip prosthesis heads. The dimpled surfaces were then coated by hydrogenated amorphous carbon (a-C:H) and tetrahedral amorphous carbon (Ta-C) layers by using a magnetron sputtering technology. A preliminary tribology test was conducted on these fabricated surfaces against a ceramic ball in simulated hip joint conditions. It was found that the fabricated dimples were perpendicular to the spherical surfaces and no cutting-tools wear debris was detected inside the individual dimples. The a-C:H and Ta-C coatings increased the hardness at both the dimple edges and the nondimpled region. The tribology test showed a significant reduction in friction coefficient for coated surfaces regardless of microdimple arrays: the lowest friction coefficient was found for the a-C:H samples (µ = 0.084), followed by Ta-C (µ = 0.119), as compared to the SS surface (µ = 0.248).
  13. Ataollahi Oshkour A, Pramanik S, Mehrali M, Yau YH, Tarlochan F, Abu Osman NA
    J Mech Behav Biomed Mater, 2015 Sep;49:321-31.
    PMID: 26072197 DOI: 10.1016/j.jmbbm.2015.05.020
    This study aimed to investigate the structural, physical and mechanical behavior of composites and functionally graded materials (FGMs) made of stainless steel (SS-316L)/hydroxyapatite (HA) and SS-316L/calcium silicate (CS) employing powder metallurgical solid state sintering. The structural analysis using X-ray diffraction showed that the sintering at high temperature led to the reaction between compounds of the SS-316L and HA, while SS-316L and CS remained intact during the sintering process in composites of SS-316L/CS. A dimensional expansion was found in the composites made of 40 and 50 wt% HA. The minimum shrinkage was emerged in 50 wt% CS composite, while the maximum shrinkage was revealed in samples with pure SS-316L, HA and CS. Compressive mechanical properties of SS-316L/HA decreased sharply with increasing of HA content up to 20 wt% and gradually with CS content up to 50 wt% for SS-316L/CS composites. The mechanical properties of the FGM of SS-316L/HA dropped with increase in temperature, while it was improved for the FGM of SS-316L/CS with temperature enhancement. It has been found that the FGMs emerged a better compressive mechanical properties compared to both the composite systems. Therefore, the SS-316L/CS composites and their FGMs have superior compressive mechanical properties to the SS-316L/HA composites and their FGMs and also the newly developed FGMs of SS-316L/CS with improved mechanical and enhanced gradation in physical and structural properties can potentially be utilized in the components with load-bearing application.
  14. Asadi-Eydivand M, Ebadzadeh MM, Solati-Hashjin M, Darlot C, Abu Osman NA
    Biol Cybern, 2015 Dec;109(6):561-74.
    PMID: 26438095 DOI: 10.1007/s00422-015-0661-7
    The demand today for more complex robots that have manipulators with higher degrees of freedom is increasing because of technological advances. Obtaining the precise movement for a desired trajectory or a sequence of arm and positions requires the computation of the inverse kinematic (IK) function, which is a major problem in robotics. The solution of the IK problem leads robots to the precise position and orientation of their end-effector. We developed a bioinspired solution comparable with the cerebellar anatomy and function to solve the said problem. The proposed model is stable under all conditions merely by parameter determination, in contrast to recursive model-based solutions, which remain stable only under certain conditions. We modified the proposed model for the simple two-segmented arm to prove the feasibility of the model under a basic condition. A fuzzy neural network through its learning method was used to compute the parameters of the system. Simulation results show the practical feasibility and efficiency of the proposed model in robotics. The main advantage of the proposed model is its generalizability and potential use in any robot.
  15. Daneshjoo A, Abu Osman NA, Sahebozamani M, Yusof A
    PLoS One, 2015;10(11):e0143323.
    PMID: 26599336 DOI: 10.1371/journal.pone.0143323
    PURPOSE: Running at high speed and sudden change in direction or activity stresses the knee. Surprisingly, not many studies have investigated the effects of sprinting on knee's kinetics and kinematics of soccer players. Hence, this study is aimed to investigate indices of injury risk factors of jumping-landing maneuvers performed immediately after sprinting in male soccer players.

    METHODS: Twenty-three collegiate male soccer players (22.1±1.7 years) were tested in four conditions; vertical jump (VJ), vertical jump immediately after slow running (VJSR), vertical jump immediately after sprinting (VJFR) and double horizontal jump immediately after sprinting (HJFR). The kinematics and kinetics data were measured using Vicon motion analyzer (100Hz) and two Kistler force platforms (1000Hz), respectively.

    RESULTS: For knee flexion joint angle, (p = 0.014, η = 0.15) and knee valgus moment (p = 0.001, η = 0.71) differences between condition in the landing phase were found. For knee valgus joint angle, a main effect between legs in the jumping phase was found (p = 0.006, η = 0.31), which suggests bilateral deficit existed between the right and left lower limbs.

    CONCLUSION: In brief, the important findings were greater knee valgus moment and less knee flexion joint angle proceeding sprint (HJFR & VJFR) rather than no sprint condition (VJ) present an increased risk for knee injuries. These results seem to suggest that running and sudden subsequent jumping-landing activity experienced during playing soccer may negatively change the knee valgus moment. Thus, sprinting preceding a jump task may increase knee risk factors such as moment and knee flexion joint angle.

  16. Chan BT, Lim E, Ong CW, Abu Osman NA
    PMID: 23521137 DOI: 10.1080/10255842.2013.779683
    Despite the advancement of cardiac imaging technologies, these have traditionally been limited to global geometrical measurements. Computational fluid dynamics (CFD) has emerged as a reliable tool that provides flow field information and other variables essential for the assessment of the cardiac function. Extensive studies have shown that vortex formation and propagation during the filling phase acts as a promising indicator for the diagnosis of the cardiac health condition. Proper setting of the boundary conditions is crucial in a CFD study as they are important determinants, that affect the simulation results. In this article, the effect of different transmitral velocity profiles (parabolic and uniform profile) on the vortex formation patterns during diastole was studied in a ventricle with dilated cardiomyopathy (DCM). The resulting vortex evolution pattern using the uniform inlet velocity profile agreed with that reported in the literature, which revealed an increase in thrombus risk in a ventricle with DCM. However the application of a parabolic velocity profile at the inlet yields a deviated vortical flow pattern and overestimates the propagation velocity of the vortex ring towards the apex of the ventricle. This study highlighted that uniform inlet velocity profile should be applied in the study of the filling dynamics in a left ventricle because it produces results closer to that observed experimentally.
  17. Shafiei SS, Solati-Hashjin M, Samadikuchaksaraei A, Kalantarinejad R, Asadi-Eydivand M, Abu Osman NA
    PLoS One, 2015;10(8):e0136530.
    PMID: 26317853 DOI: 10.1371/journal.pone.0136530
    In recent years, nanotechnology in merging with biotechnology has been employed in the area of cancer management to overcome the challenges of chemopreventive strategies in order to gain promising results. Since most biological processes occur in nano scale, nanoparticles can act as carriers of certain drugs or agents to deliver it to specific cells or targets. In this study, we intercalated Epigallocatechin-3-Gallate (EGCG), the most abundant polyphenol in green tea, into Ca/Al-NO3 Layered double hydroxide (LDH) nanoparticles, and evaluated its efficacy compared to EGCG alone on PC3 cell line. The EGCG loaded LDH nanohybrids were characterized by X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy (TEM) and nanosizer analyses. The anticancer activity of the EGCG-loaded LDH was investigated in prostate cancer cell line (PC3) while the release behavior of EGCG from LDH was observed at pH 7.45 and 4.25. Besides enhancing of apoptotic activity of EGCG, the results showed that intercalation of EGCG into LDH can improve the anti- tumor activity of EGCG over 5-fold dose advantages in in-vitro system. Subsequently, the in-vitro release data showed that EGCG-loaded LDH had longer release duration compared to physical mixture, and the mechanism of diffusion through the particle was rate-limiting step. Acidic attack was responsible for faster release of EGCG molecules from LDH at pH of 4.25 compared to pH of 7.4. The results showed that Ca/Al-LDH nanoparticles could be considered as an effective inorganic host matrix for the delivery of EGCG to PC3 cells with controlled release properties.
  18. Maleki-Ghaleh H, Hafezi M, Hadipour M, Nadernezhad A, Aghaie E, Behnamian Y, et al.
    PLoS One, 2015;10(9):e0138454.
    PMID: 26383641 DOI: 10.1371/journal.pone.0138454
    In the current study, a sol-gel-synthesized tricalcium magnesium silicate powder was coated on Ti-6Al-4V alloys using plasma spray method. Composition of feed powder was evaluated by X-ray diffraction technique before and after the coating process. Scanning electron microscopy and atomic force microscopy were used to study the morphology of coated substrates. The corrosion behaviors of bare and coated Ti-6Al-4V alloys were examined using potentiodynamic polarization test and electrochemical impedance spectroscopy in stimulated body fluids. Moreover, bare and coated Ti-6Al-4V alloys were characterized in vitro by culturing osteoblast and mesenchymal stem cells for several days. Results demonstrated a meaningful improvement in the corrosion resistance of Ti-6Al-4V alloys coated with tricalcium magnesium silicate compared with the bare counterparts, by showing a decrease in corrosion current density from 1.84 μA/cm2 to 0.31 μA/cm2. Furthermore, the coating substantially improved the bioactivity of Ti-6Al-4Valloys. Our study on corrosion behavior and biological response of Ti-6Al-4V alloy coated by tricalcium magnesium silicate proved that the coating has considerably enhanced safety and applicability of Ti-6Al-4V alloys, suggesting its potential use in permanent implants and artificial joints.
  19. El-Sayed AM, Hamzaid NA, Tan KY, Abu Osman NA
    ScientificWorldJournal, 2015;2015:923286.
    PMID: 25945365 DOI: 10.1155/2015/923286
    This paper presents an approach of identifying prosthetic knee movements through pattern recognition of mechanical responses at the internal socket's wall. A quadrilateral double socket was custom made and instrumented with two force sensing resistors (FSR) attached to specific anterior and posterior sites of the socket's wall. A second setup was established by attaching three piezoelectric sensors at the anterior distal, anterior proximal, and posterior sites. Gait cycle and locomotion movements such as stair ascent and sit to stand were adopted to characterize the validity of the technique. FSR and piezoelectric outputs were measured with reference to the knee angle during each phase. Piezoelectric sensors could identify the movement of midswing and terminal swing, pre-full standing, pull-up at gait, sit to stand, and stair ascent. In contrast, FSR could estimate the gait cycle stance and swing phases and identify the pre-full standing at sit to stand. FSR showed less variation during sit to stand and stair ascent to sensitively represent the different movement states. The study highlighted the capacity of using in-socket sensors for knee movement identification. In addition, it validated the efficacy of the system and warrants further investigation with more amputee subjects and different sockets types.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links