  1. Elvy Suhana MR, Farihah HS, Faizah O, Nazrun AS, Norazlina M, Norliza M, et al.
    Singapore Med J, 2011 Nov;52(11):786-93.
    PMID: 22173247
    Glucocorticoids cause osteoporosis by decreasing bone formation and increasing bone resorption activity. Glucocorticoid action in bones depends on the activity of 11-beta-hydroxysteroid dehydrogenase type 1 (11β-HSD1) enzyme, which plays an important role in regulating corticosteroids. 11β-HSD1 is expressed by human and rat osteoblasts. We aimed to investigate the relationship between 11β-HSD1 dehydrogenase activity and bone histomorphometric changes in glucocorticoid-induced osteoporotic bone in rats.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  2. Samad SA, Rahman HA
    Singapore Med J, 1999 Aug;40(8):513-8.
    PMID: 10572490
    The purpose of this study was to retrospectively detect Aspergillus antigens in sera obtained from immunocompromised host using an in-house modified double antibody sandwich ELISA.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  3. Vadivelu J, Puthucheary SD, Gendeh GS, Parasakthi N
    Singapore Med J, 1995 Jun;36(3):299-302.
    PMID: 8553097
    Current diagnosis of melioidosis is based on bacterial culture and/or serology which is becoming increasingly useful. An IgM-ELISA using heat-killed whole cells of Pseudomonas pseudomallei was developed and compared with an indirect haemagglutination technique (IHAT) and an indirect immunofluorescent technique(IFAT). The IgM-ELISA using a P:N ratio of > or = 2 had a sensitivity of 91% and a specificity of 96%. All 3 assays were further used in a seroepidemiological survey amongst different groups of patients and healthy individuals. It was found that the IFAT performed better than the IHAT, detecting antibodies to P. pseudomallei in 6% of diabetics, 5% of pyrexics, 8% of pregnant women and 3% of farmers. For the same groups the IgM-ELISA detected antibodies in 1% of pyrexics, 8% of pregnant women and a further 14% of farmers. The IgM-ELISA was found to be sensitive and useful for the serological diagnosis of acute melioidosis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  4. Kumarasamy V, Chua SK, Hassan Z, Wahab AH, Chem YK, Mohamad M, et al.
    Singapore Med J, 2007 Jul;48(7):669-73.
    PMID: 17609831
    INTRODUCTION: The aim of this report is to establish an accurate diagnosis of acute dengue virus infection early, in order to provide timely information for the management of patients and early public health control of dengue outbreak.
    METHODS: 224 serum samples from patients with a clinical diagnosis of acute dengue infection, which were subsequently confirmed by laboratory tests, were used to evaluate the performance of a commercially-available dengue NS1 antigen-capture ELISA kit.
    RESULTS: The dengue NS1 antigen-capture ELISA gave an overall sensitivity rate of 93.3 percent (209/224). The sensitivity rate was significantly higher in acute primary dengue (97.4 percent) than in acute secondary dengue (68.8 percent). In comparison, the virus isolation gave an overall positive isolation rate of 64.7 percent, with a positive rate of 70.8 percent and 28.1 percent, for acute primary dengue and acute secondary dengue, respectively. Molecular detection of dengue RNA by RT-PCR gave an overall positive detection rate of 63.4 percent, with a positive rate of 62.5 percent and 68.8 percent, for acute primary dengue and acute secondary dengue, respectively. Of the 224 acute serum samples from patients with laboratory-confirmed acute dengue infection, dengue IgM was detected in 88 specimens, comprising 68 acute primary dengue specimens and 20 acute secondary dengue specimens. NS1 antigen-capture ELISA kit gave an overall sensitivity rate of 88.6 percent in the presence of anti-dengue IgM and 96.3 percent in the absence of anti-dengue IgM.
    CONCLUSION: Of the 224 acute serum samples, the sample ages of 166 acute serum samples are known. The positive detection rate of dengue NS1 antigen-capture ELISA, on the whole, was higher than the other three established diagnostic test methods for laboratory diagnosis of acute dengue infection.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  5. Rahumatullah A, Lim TS, Yunus MH, Noordin R
    Am J Trop Med Hyg, 2019 08;101(2):436-440.
    PMID: 31162018 DOI: 10.4269/ajtmh.19-0034
    Lymphatic filariasis is a mosquito-borne parasitic disease responsible for morbidity and disability that affects 1.2 billion people worldwide, mainly the poor communities. Currently, filarial antigen testing is the method of choice for the detection of bancroftian filariasis, and to date, there are two commonly used tests. In the present study, a recently reported recombinant monoclonal antibody (5B) specific to BmSXP filarial antigen was used in developing an ELISA for the detection of circulating filarial antigen in sera of patients with bancroftian filariasis. The performance of the ELISA was evaluated using 124 serum samples. The ELISA was positive with all sera from microfilaremic bancroftian filariasis patients (n = 34). It also showed 100% diagnostic specificity when tested with sera from 50 healthy individuals and 40 patients with other parasitic diseases. The developed assay using the novel 5B recombinant monoclonal antibody could potentially be a promising alternative antigen detection test for bancroftian filariasis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  6. Wongphutorn P, Noordin R, Anuar NS, Worasith C, Kopolrat KY, Homwong C, et al.
    Am J Trop Med Hyg, 2024 Feb 07;110(2):254-262.
    PMID: 38190756 DOI: 10.4269/ajtmh.23-0518
    Strongyloidiasis, caused by Strongyloides stercoralis, is a neglected tropical disease with a global distribution. The infection can be fatal in immunocompromised individuals, and accurate diagnosis leading to timely treatment can save lives. Serodiagnosis is a sensitive method for diagnosis and is recommended for screening high-risk individuals. A point-of-care rapid test will facilitate the screening activities, especially in low-resource settings. This study aims to apply a new IgG4 immunochromatographic test using S. stercoralis recombinant antigen (SsRapid® cassette test) and to compare it with in-house IgG and IgG4 enzyme-linked immunosorbent assays (IgG- and IgG4-ELISAs) using native Strongyloides ratti antigen to investigate the epidemiology of strongyloidiasis in northeast Thailand. A total of 300 people participated, with 136 males and 164 females of a similar mean age. The reference tests were fecal examinations using the formalin-ethyl acetate concentration technique and an agar plate culture technique. The prevalence of S. stercoralis determined by SsRapid (81.7%) was significantly higher than that by fecal examinations (43.3%) or by antibody detection by IgG-ELISA (53.0%) or IgG4-ELISA (44.0%). The diagnostic sensitivities of SsRapid, IgG-ELISA, and IgG4-ELISA were found to be 93.9%, 77.7%, and 63.1%, respectively. The rate of positive tests by the SsRapid was significantly correlated to the levels of Strongyloides-specific IgG4 and IgG antibodies. By all diagnostic methods, male participants had a significantly higher prevalence of strongyloidiasis than females. Age was significantly associated with the concentration of specific serum IgG but not with the SsRapid grading score. In conclusion, SsRapid was shown to be a sensitive and valuable diagnostic test for the epidemiology study of strongyloidiasis.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  7. Yunus MH, Tan Farrizam SN, Abdul Karim IZ, Noordin R
    Am J Trop Med Hyg, 2018 Jan;98(1):32-38.
    PMID: 29141740 DOI: 10.4269/ajtmh.17-0632
    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara-positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  8. Radhakrishnan AK, Lee AL, Wong PF, Kaur J, Aung H, Nesaretnam K
    Br J Nutr, 2009 Mar;101(6):810-5.
    PMID: 18702848 DOI: 10.1017/S0007114508039998
    Vitamin E is divided into two subgroups; tocopherols and tocotrienols. Both have protective roles in biological systems. The present study was conducted to compare the effect of short-term supplementation at 200 mg/d of either alpha-tocopherol or a tocotrienol-rich fraction (TRF) from palm oil on immune modulation and plasma vitamin E levels in normal healthy Asian volunteers. In a randomised, double-blind placebo-controlled trial conducted, fifty-three healthy volunteers aged 20-50 years were recruited based on the study's inclusion and exclusion criteria. They were randomly assigned into three groups, i.e. two experimental groups that received daily supplementation at 200 mg of either alpha-tocopherol or the TRF, and the control group that received a placebo. Blood was drawn on days 0, 28 and 56 for several laboratory analyses. Differences in the production of IL-4 or interferon-gamma by concanavalin A-stimulated lymphocytes isolated from these volunteers were not significant (P>0.05). There were no significant differences observed in immune parameters between the healthy volunteers who received daily supplementation with either alpha-tocopherol or the TRF. As these observations were made in the absence of any immunogenic challenge, we feel it would be of benefit to study if there would be any differences observed when an immunogenic challenge such as vaccination were introduced.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  9. Kuo IC, Cheong N, Trakultivakorn M, Lee BW, Chua KY
    J Allergy Clin Immunol, 2003 Mar;111(3):603-9.
    PMID: 12642844
    BACKGROUND: Dual sensitization by Blomia tropicalis and Dermatophagoides pteronyssinus mites is common in tropical and subtropical countries. The human IgE cross-reactivity between clinical important group 5 allergens, Blo t 5 and Der p 5, remains controversial.

    OBJECTIVE: This study was undertaken to assess the levels of the IgE cross-reactivity between Blo t 5 and Der p 5 by using sera from a large cohort of asthmatic children in subtropical and tropical countries.

    METHODS: Purified recombinant Blo t 5 and Der p 5 were produced in Pichia pastoris and tested against sera from 195 asthmatic children. The IgE cross-reactivity was examined by direct, inhibitory and competitive human IgE enzyme-linked immunosorbent assay as well as skin prick tests.

    RESULTS: The Blo t 5 IgE responses were 91.8% (134 of 146) and 73.5% (36 of 49) for Taiwanese and Malaysian sera, respectively. The Blo t 5 specific IgE titers were significantly higher than those of Der p 5 (P

    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  10. Hasmoni SS, Yusoff K, Tan WS
    J Gen Appl Microbiol, 2005 Apr;51(2):125-31.
    PMID: 15942873
    The nucleocapsids of hepatitis B virus (HBV) are made of 180 or 240 subunits of core proteins or known as core antigens (HBcAg). A fusion bacteriophage bearing the WSFFSNI sequence that interacts tightly to HBcAg was employed as a diagnostic reagent for the detection of the antigen using the phage-enzyme-linked immunosorbent (phage-ELISA), dot blot and immunoprecipitation assays. The results from phage-ELISA and dot blot assay showed that as low as 10 ng of HBcAg can be detected optimally by 1.0x10(12) pfu/ml fusion M13 bacteriophage. The sensitivity of the dot blot assay corresponds with that of the phage-ELISA. HBcAg in HBV positive serum samples can also be detected using the fusion phage via the phage-ELISA and phage-dot blot assay. The phage cross-linked to cyanogen bromide (CNBr) activated agarose can also be used to precipitate HBcAg in bacterial lysate. The optimum amount of phage needed for cross-linking to 1 g of agarose is about 7.0x10(6) pfu/ml which could also precipitate purified and unpurified HBcAg in bacterial lysate. This study demonstrates the potential of fusion bacteriophage bearing the sequence WSFFSNI as a diagnostic reagent and a ligand for the detection and purification of HBcAg respectively.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  11. Chua KB, Mustafa B, Abdul Wahab AH, Chem YK, Khairul AH, Kumarasamy V, et al.
    Malays J Pathol, 2011 Jun;33(1):13-20.
    PMID: 21874746
    A prospective study was carried out to evaluate the sensitivity of dengue NS1 antigen-capture ELISA in comparison with dengue virus isolation, conventional RT-PCR and real-time RT-PCR for laboratory confirmation of acute dengue based on single-acute serum samples. Four primary healthcare centres were involved to recruit patients with clinical diagnosis of dengue illness. Patient's demographic, epidemiological and clinical information were collected on a standardized data entry form and 5 ml of venous blood was collected upon consent. In the laboratory, six types of laboratory tests were performed on each of the collected acute serum sample. Of the 558 acute serum samples collected from 558 patients with clinical diagnosis of dengue from mid-August 2006 to March 2009, 174 serum samples were tested positive by the dengue NS1 antigen-capture ELISA, 77 by virus isolation, 92 by RT-PCR and 112 by real-time RT-PCR. A total of 190 serum samples were tested positive by either one or a combination of the four methods whereas, only 59 serum samples were tested positive by all four methods. Thus, based on single-acute serum samples, 190 of the 558 patients (34.1%) were laboratory-confirmed acute dengue. The overall test sensitivity was 91.6%, 40.5%, 48.4% and 58.9% for dengue NS1 antigen-capture ELISA, virus isolation, conventional RT-PCR and real-time RT-PCR respectively. Statistically, dengue NS1 antigen-capture ELISA was the most sensitive and virus isolation was the least sensitive test for the laboratory confirmation of acute dengue based on single-acute serum specimens. Real-time RT-PCR was significantly more sensitive than the conventional RT-PCR.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  12. Ng LC, Teng LC, Ng ML, Sazali BS, Khalid BA
    Malays J Pathol, 2000 Dec;22(2):73-8.
    PMID: 16329538
    Detection of microalbuminuria is important in the management of diabetic patients since it is predictive of development of proteinuria and nephropathy. Two sensitive and specific in-house ELISAs for microalbuminuria were established and validated. One of the ELISAs was based on antigen coating while the other employed antibody coating. Recovery and linearity experiments gave acceptable results of 100 +/- 10%, while precision results were <10% for intra-assay and <12% for inter-assay coefficients of variation (CVs). The standard curve ranged from 10-625 ug/l, equivalent to 0.2-12.5 mg/l for urine samples diluted 1:20 fold. When the antibody coated ELISA was compared to antigen coated ELISA, a correlation of r=0.996 was obtained. When compared to commercial kits, the in-house ELISAs gave good correlations of r=0.961 versus the Boehringer Mannheim Micral Test strips and r=0.940 versus Ames Microalb Turbidimetry. The normal microalbumin reference ranges determined for 12h, first morning and random urine samples were 0.7-5.3 mg, 0.1-10.2 mg/l and 0.8-26.1 mg/l respectively. The normal albumin excretion rate (AER) was 1.0-7.3 ug/min while untimed urine samples gave results of 0.1-0.9 and 0.2-1.6 mg/mmol after dividing by creatinine concentrations. The ELISAs were used to detect microalbuminuria in 338 random urine samples from diabetic patients. A high percentage 47.9% was found to be positive for microalbuminuria and 18.0% had macroalbuminuria >25 mg/mmol. Thus screening for microalbuminuria together with creatinine measurements using random urine samples can be used for management of diabetic patients.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  13. Kirnpal-Kaur BS, Yap KL, Tan SC
    Malays J Pathol, 1997 Dec;19(2):133-6.
    PMID: 10879254
    A blocking test was incorporated into the commercial IDEIA Adenovirus test (DAKO Diagnostics Ltd., Cambridgeshire, UK) to detect false positive results when faecal specimens were tested for adenovirus antigen. Immune rabbit serum raised against pooled adenovirus particles from human faecal specimens, together with the pre-immune serum, was used. Assessment of positive showed that false positives were produced under two different conditions: when results were based on visual determination instead of a cut-off value determined from photometric reading, and when absorbance values were not immediately read at the end of the test. Under the optimum condition for reading and assessment of test results (immediate reading and photometric determination), 11% of 65 adenovirus-positive samples were checked by the blocking ELISA as false positives. The rest of the specimens showed blocking of positive absorbance values by 70 to 98%. ELISA was found to be more sensitive than immune electron microscopy on samples with lower antigen concentration.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  14. Lam SK
    Malays J Pathol, 1993 Jun;15(1):9-12.
    PMID: 8277797
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  15. Nazaimoon W, Ng ML, Bak K
    Malays J Pathol, 1993 Jun;15(1):75-83.
    PMID: 8277795
    A simple, non-isotopic in-house enzyme-linked immunoabsorbant assay (ELISA) for human growth hormone (GH) was developed. The assay involved using in-house polyclonal anti-GH adsorbed onto 96-well microtitre plates, commercially prepared mouse monoclonal anti-GH, and goat anti-mouse IgG horseradish peroxidase detection system. Results of recovery and parallelism studies ranged from 95%-106% and 98%-101% respectively, of the expected values. The detection limit of the assay was 0.008 mIU/well or the equivalent to 0.4 mIU/L of undiluted serum. Intra- and interassay coefficients of variations were 4.8%-7.9% and 6.5%-8.7% respectively. Serum GH levels measured in this assay correlated well with those measured in established in-house radioimmunoassays (r = 0.985, p < 0.001) and immunoradiometric assay from NETRIA (r = 0.984, p < 0.001).
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  16. Cheong KB, Cheong SK, Boo NY, Jemilah M, Ton SH
    Malays J Pathol, 1995 Dec;17(2):91-6.
    PMID: 8935133
    An in-house enzyme-linked immunoabsorbant assay (ELISA) for SP-A was successfully developed using in-house polyclonal anti SP-A and a commercial polyclonal anti-rabbit immunoglobulin horseradish peroxidase conjugate system. The standard curve, generated by using 50 ng of SP-A to coat the plate and 1:500 dilution of polyclonal anti SP-A as a primary antibody, was linear for concentrations of SP-A ranging from 4 micrograms/l to 4000 micrograms/l and reproducible. Results of recovery study of SP-A from a known sample of tracheal aspirate ranged from 94%-114%. Intra- and inter-assay coefficients of variations were 2.7% and 5.6% respectively for a known sample of tracheal aspirate. Interference study showed that tracheal aspirate did not interfere with the assay. The assay developed was intended to be used for SP-A measurement in tracheal aspirates obtained from neonates with and without respiratory distress syndrome.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  17. Tay SP, Cheong SK
    Malays J Pathol, 2002 Jun;24(1):45-51.
    PMID: 16329555
    Tissue Factor (TF) is a low molecular weight transmembrane glycoprotein that initiates the clotting protease cascade. It is considered to be the principal regulator of the extrinsic coagulation pathway, hemostasis and thrombosis, as well as inflammation and cellular immune response. An in-house two-step direct sandwich ELISA (enzyme-linked immunosorbent assay) for immunological quantification of plasma TF was successfully developed. The assay employed a monoclonal antibody against human TF (1:400 dilution; 1250 ng/ml) and peroxidase-conjugated anti-TF IgG (1:1000 dilution; 2000 ng/ml) as capture and detecting antibodies respectively, whilst tetramethylbenzidine/H2O2 were utilized as substrates. Titration curves of recombinant TF were linear within 10 to 4000 pg/ml, with a detection limit of 36.31 pg/ml. It demonstrated low intra- (2.50 - 9.23 CV%) and inter-assays (5.65 - 13.57 CV%) variability, as well as satisfactory analytical recovery (91.55 - 103.95%) and good parallelism. The assay developed was intended to be applied for measurement of plasma TF levels in patients with thrombotic disorders.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  18. Goh KH, Goh ML, Thean ET, Khalid BA
    Med J Malaysia, 1992 Dec;47(4):248-60.
    PMID: 1303476
    A supersensitive ELISA was developed for measurement of thyroid-stimulating hormone (TSH) concentrations in serum using in-house rabbit polyclonal antisera and a commercial monoclonal antibody. The assay was optimised and validated by recovery, linearity and cross-reactivity experiments and further compared to other available assays and EQAS samples. Good precision was obtained with a working assay range of 0.2 to 100 mIU/L with < 10% coefficient of variation (CV) for both intra and interassay. The assay is highly sensitive and specific with a minimum detectable limit of 0.07 mIU/L and negligible cross-reactivities against LH, FSH, HCG and other pituitary peptides. Good correlations were obtained when compared to Abbott hTSH EIA (r = 0.993; p < 0.001; n = 85) and NETRIA IRMA (r + 0.995; p < 0.001; n = 76). The normal reference range established was 0.4 to 4.0 mIU/L (n = 76). TSH levels in serum of thyrotoxic patients (n = 83) were significantly lower (0.07 to 0.20 mIU/L, p < 0.0001) and completely distinct from normal values thereby obviating the requirement of a TRH-stimulation test. Stability studies showed that coated wells can be stored at 4 degrees C for at least 2 months. This highly sensitive in-house hTSH ELISA which is cheap, stable and readily available is useful for diagnosis and management of patients with various thyroid disorders.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods*
  19. Mak JW, Khalid BA
    Med J Malaysia, 1992 Dec;47(4):235-7.
    PMID: 1303475
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods
  20. Kassim FM, Izati MN, TgRogayah TA, Apandi YM, Saat Z
    PMID: 21706934
    Accurate and timely diagnosis of dengue virus is important for early detection of dengue virus infection. In this study, the usefulness of the dengue NS1 antigen test was evaluated as a routine, rapid diagnostic test for dengue virus infection. A total of 208 sera from patients suspected of having dengue virus infection were collected and tested for dengue antibody, dengue genome and dengue NS1 antigen. Dengue antibody test, dengue PCR test and dengue antigen test were able to detect dengue virus infection from Days 1 to 8 in 72.8, 52.8 and 44.0% of samples, respectively. Of the 208 sera tested, 69.2% (144/208) of the acute sera were positive for dengue virus infection based on IgM antibody, IgG antibody, NS1 antigen and PCR tests. Thirty-two point two percent of the samples (67/208) were found positive for dengue NS1 antigen, 38.5% (80/208) were PCR positive, 40.9% (85/208) were IgM positive and 36.1% (75/208) were IgG positive for dengue virus. The results reveal the detection rate of dengue virus infection was similar for PCR and dengue antibody (65.9%) and for NS1 antigen and dengue antibody (62.0%) combinations. Therefore, the dengue NS1 antigen test can be used to complement the current antibody test used in peripheral laboratories. Thus, the combination of the NS1 antigen and antibody tests could increase the diagnostic efficiency for early diagnosis of dengue infection.
    Matched MeSH terms: Enzyme-Linked Immunosorbent Assay/methods