Displaying publications 61 - 73 of 73 in total

Abstract:
Sort:
  1. Ithnin A, Zubir A, Awang N, Mohamad Sulaiman NN
    Pak J Biol Sci, 2019 Jan;22(3):143-147.
    PMID: 30972984 DOI: 10.3923/pjbs.2019.143.147
    BACKGROUND AND OBJECTIVE: Welding fume exposure has led to the respiratory problems among welders including cough, phlegm, chest illnesses, nausea and fatigue. Inadequate ventilation during welding works causes the situation to worsen. Welding fumes can cause a decrease in lung function among welders. Chronic exposure will lead to other health effects especially COPD (Chronic Obstructive Pulmonary Disease). The objective of this study is to determine the exposure of welding fumes (Cd, Fe, Pb and Zn) towards respiratory health including lung function test (FEV1, FVC, FEV1/FVC, PEFR) of workers in Lumut shipyard, Perak.

    MATERIAL AND METHODS: This research study the relationship between exposures of welding fumes towards lung function test among workers in Lumut shipyard, Perak. Lung function test was measured by spirometry among 30 welders and 31 non-welders. The concentration welding fume exposure was measured using OSHA ID-121 method. Sociodemographic data, respiratory symptoms and smoking habit data was analyzed based on the ATS 1987 questionnaire.

    RESULTS: The mean concentration for Pb in welding fumes was 2.752 mg m-3 which is above 0.5 mg m-3 PEL-TWA. The FEV1 and FVC readings showed significant different between welders and non-welders (p = 0.001). Cough and phlegm symptoms showed significant different between welders and non-welders (p = 0.001). Welders had higher prevalence in smoking habit than the non-welders. Chest illnesses symptom showed an association with the smoking habit (p = 0.01).

    CONCLUSION: There is relationship between welding fumes exposure on lung function test of workers in Lumut shipyard. Pb in welding fumes has high concentration and exceeded PEL-TWA level. The FEV1 and FVC in welders are lower than non-welder due to the fumes exposure. Welders showed higher respiratory symptoms than non-welders. Smoking habit is a contributing factor towards respiratory problem.
    Matched MeSH terms: Forced Expiratory Volume
  2. Loh LC, Puah SH, Ho CV, Chow CY, Chua CY, Jayaram J, et al.
    J Asthma, 2005 Dec;42(10):853-8.
    PMID: 16393724
    Measurement of disability and breathlessness in asthma is important to guide treatment. Using an incentive spirometer, Triflo II (Tyco Healthcare, Mansfield, MA, USA), we developed a three-minute respiratory exercise test (3-MRET) to score the maximal breathing capacity (MBC) and perception of dyspnea (POD) index by means of repetitive inspiratory efforts achieved within 3 minutes. POD index was calculated based on the ratio of breathlessness on visual analogue scale over MBC score. In 175 normal healthy subjects and 158 asthmatic patients of mild (n = 26), moderate (n = 78), and severe (n = 54), severity, the mean (95% CI) MBC scores in mild, moderate, and severe asthma patients were 168 (145-192), 153 (136-169), and 125 (109-142) respectively, and 202 (191-214) in normal subjects (p < 0.001). The mean POD index in mild, moderate, and severe asthma patients was 16 (9-23), 25 (14-37), and 57 (14-100), respectively, and 6 (4-7) in normal subjects (p < 0.001). Intraclass correlation coefficients for MBC score and POD index in 17 asthmatic and 20 normal subjects were high. In 14 asthmatic patients randomized to receiving nebulized beta2-agonist or saline in a cross-over, double-blind study, % forced expiratory volume in one second (FEV1) change correlated with % change in MBC score [r(s) = 0.49, p < 0.01] and POD index [r(s)-0.46, p = 0.012]. In 21 asthmatic and 26 normal subjects, the MBC score and POD index correlated with the walking distance and walking POD index of the six-minute walking test (6MWT). We conclude that 3MRET is discriminative between asthmatic patients of varying severity and normal subjects, is reproducible, is responsive to bronchodilator effect, and is comparable with 6MWT. Taken together, it has the potential to score disability and POD in asthma simply and effectively.
    Matched MeSH terms: Forced Expiratory Volume
  3. Loh LC, Kanabar V, D'Amato M, Barnes NC, O'Connor BJ
    Asian Pac J Allergy Immunol, 2005 Dec;23(4):189-96.
    PMID: 16572738
    Sputum induction with nebulized hypertonic saline is increasingly being used to evaluate airway inflammation. We investigated the procedure-associated risk in 16 asthmatics that were still symptomatic despite on high doses of regular corticosteroid (CS) therapy (7 on daily inhaled CS > or = 800 microg budesonide or equivalent; 9 on additional daily oral CS) and their sputum cellular profile. For comparison, 12 mild stable asthmatics and 10 normal healthy subjects were included. All subjects inhaled 3%, 4% and 5% hypertonic saline sequentially via ultrasonic nebulizer as a means to induce sputum. Maximal percentage fall of Forced Expiratory Volume on One Second (FEV1) during sputum induction was significantly greater in CS-dependent asthmatics (median % [IQR]: 16.0 [11.0-32.3]) than in mild asthmatics (5.3 [4.2-10.8], p = 0.002] and in normal subjects (4.6 [3.4-6.4]), p = 0.0001). The maximal percentage FEV1 fall was inversely correlated with baseline FEV1 (Rs= -0.69; p < 0.0001). Compared to mild asthmatics, induced sputum from CS-dependant asthmatics had proportionately fewer eosinophils (2.2 [0.8-7.0] versus 23.3% [10.7-46.3], p = 0.003) and greater neutrophils (64.2 [43.9-81.2] versus 28.7 [19.0-42.6], p = 0.009). Sputum neutrophils showed a significant inverse correlation to FEV1 (Rs = -0.51, p = 0.01). We concluded that sputum induction using nebulized hypertonic saline should be performed with caution in CS-dependant asthmatics. The airway cellular profile observed suggests that the immunopathology underlying CS-dependant asthmatics may be different or a consequence of CS therapy.
    Matched MeSH terms: Forced Expiratory Volume
  4. Pirabbasi E, Najafiyan M, Cheraghi M, Shahar S, Abdul Manaf Z, Rajab N, et al.
    Glob J Health Sci, 2013 Jan;5(1):70-8.
    PMID: 23283038 DOI: 10.5539/gjhs.v5n1p70
    Imbalance between antioxidant and oxidative stress is a major risk factor for pathogenesis of some chronic diseases such as chronic obstructive pulmonary disease (COPD). This study aimed to determine antioxidant and oxidative stress status, and also theirs association with respiratory function of male COPD patients to find the antioxidant predictors' factors. A total of 149 subjects were involved in a cross-sectional study. The study was conducted at two medical centers in Kuala Lumpur, Malaysia. Results of the study showed that plasma vitamin C was low in most of the subjects (86.6%). Total antioxidant capacity was the lowest in COPD stage IV compare to other stages (p < 0.05). Level of plasma vitamin A (p= 0.012) and vitamin C (p= 0.007) were low in malnourished subjects. The predictors for total antioxidant capacity were forced vital capacity (FVC) % predicted and intake of ?-carotene (R2= 0.104, p= 0.002). Number of cigarette (pack/ year) and smoking index (number/ year) were not associated with total antioxidant capacity of this COPD population. Plasma oxidative stress as assessed plasma lipid peroxidation (LPO) was only positively correlated with plasma glutathione (p= 0.002). It might be a need to evaluate antioxidant status especially in older COPD patients to treat antioxidant deficiency which is leading to prevent COPD progression.
    Study site: Outpatient clinics, Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM) and Institute of Respiratory Medicine, Kuala Lumpur, Malaysia
    Matched MeSH terms: Forced Expiratory Volume
  5. Norhaya MR, Yap TM, Zainudin BM
    Respirology, 1999 Mar;4(1):77-81.
    PMID: 10339734 DOI: 10.1046/j.1440-1843.1999.00153.x
    The effect of adding inhaled salmeterol to inhaled corticosteroids was studied in patients with poorly controlled nocturnal asthma. In a double-blind, cross-over study, 20 patients were randomized to receive either salmeterol 50 micrograms twice daily or placebo via a Diskhaler after a 1-week run-in period. After 4 weeks of treatment, patients were subsequently crossed over to receive the other treatment for a further 4 weeks with a 2-week wash-out period in between. The response to treatment was assessed by peak expiratory flow rates (PEF) measured in the morning and evening, symptom scores of asthma, number of bronchodilators used, forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) at regular intervals. Patients' preference for the Diskhaler or metered-dose inhaler was assessed at the last visit. The results showed that morning PEF was significantly higher while on salmeterol than on placebo (296.9 +/- 70.2 vs 274.6 +/- 77.4 L/min). Evening PEF showed a trend towards a higher value while on salmeterol than on placebo (321.1 +/- 73.4 vs 288.7 +/- 79.4 L/min), but the difference was not significant. There was no statistically significant improvement in symptom scores, number of rescue bronchodilators used and FEV1 or FVC between the two treatment groups. The occurrence of side effects in terms of tremors and palpitations between treatment and placebo were similar. There were more patients who preferred Diskhaler to metered-dose inhaler (70% vs 30%). We conclude that salmeterol 50 micrograms twice daily produces significant improvement in morning PEF and is well tolerated in patients with nocturnal asthma. Diskhaler is a device which is easy to use and preferred to a metered-dose inhaler.
    Study site: Respiratory Clinic, Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM), Kuala Lumpur, Malaysia
    Matched MeSH terms: Forced Expiratory Volume
  6. Azizi BH, Henry RL
    Pediatr Pulmonol, 1990;9(1):24-9.
    PMID: 2388776
    In a cross-sectional study of 7-12 year-old primary school children in Kuala Lumpur city, lung function was assessed by spirometric and peak expiratory flow measurements. Spirometric and peak expiratory flow measurements were successfully performed in 1,214 and 1,414 children, respectively. As expected, the main predictors of forced vital capacity (FVC), forced expiratory volume in one second (FEV1), forced expiratory flow between 25% and 75% of vital capacity (FEF25-75), and peak expiratory flow rate (PEFR) were standing height, weight, age, and sex. In addition, lung function values of Chinese and Malays were generally higher than those of Indians. In multiple regression models which included host and environmental factors, asthma was associated with significant decreases in FEV1, FEF25-75, and PEFR. However, family history of chest illness, history of allergies, low paternal education, and hospitalization during the neonatal period were not independent predictors of lung function. Children sharing rooms with adult smokers had significantly lower levels of FEF25-75. Exposures to wood or kerosene stoves were, but to mosquito repellents were not, associated with decreased lung function.
    Matched MeSH terms: Forced Expiratory Volume
  7. Wu CL, Hsu WH, Chiang CD, Kao CH, Hung DZ, King SL, et al.
    J. Toxicol. Clin. Toxicol., 1997;35(3):241-8.
    PMID: 9140317 DOI: 10.3109/15563659709001207
    BACKGROUND: Taking Sauropus androgynus, a Malaysian food, to reduce weight began as a fad in Taiwan in 1994. Some advocates of this fad developed pulmonary dysfunction. The aim of this study is to report the lung injury in patients taking Sauropus androgynus.

    METHODS: From July 1995 to November 1995, we investigated 104 nonsmoking patients (one male and 103 females) with chest roentgenography, pulmonary function, test, and Technetium 99m-labeled diethylene triamine penta-acetate (Tc-99m DTPA) radioaerosol inhalation lung scintigraphy.

    RESULTS: Among the 90 patients receiving Tc-99m DTPA inhalation lung scan, 46 (51.1%) patients had increased clearance of Tc-99m DTPA from lung and 20 (22.2%) patients had inhomogeneous deposition of the submicronic radioaerosol. Eighteen (18/100) patients had obstructive ventilatory impairment in pulmonary function test. Analyzing the results, we found that the patients with respiratory symptoms (n = 42) took more vegetables (p = 0.016), had increased clearance of Tc-99m DTPA (p = 0.010) and had lower FEV1 (p = 0.001), FEV1/FVC (p < 0.001), FEF25-75 (p = 0.001), VC (p = 0.002) and DLCO (p = 0.009) than the patients without respiratory symptoms (n = 62). FEV1 and FEV1/FVC were significantly reduced in patients with severe impairment of alveolar permeability. The cumulative dosage and duration of exposure were significantly associated with the reduction of FEV1 and FEV1/FVC.

    CONCLUSION: The lung injury after taking Sauropus androgynus involves alveoli and/or small airways and is manifest as obstructive ventilatory impairment with inhomogeneous aerosol distribution and increased lung epithelial permeability.
    Matched MeSH terms: Forced Expiratory Volume
  8. Ni H, Moe S, Soe Z, Myint KT, Viswanathan KN
    Cochrane Database Syst Rev, 2018 Dec 11;12:CD011594.
    PMID: 30536566 DOI: 10.1002/14651858.CD011594.pub2
    BACKGROUND: Several dual bronchodilator combinations of long-acting beta2-agonist (LABA) and long-acting muscarinic antagonist (LAMA) have been approved for treatment of stable chronic obstructive pulmonary disease (COPD). The current GOLD (Global Initiative for Chronic Obstructive Lung Disease) recommendations suggest the use of LABA/LAMA combinations in people with group B COPD with persistent symptoms, group C COPD with further exacerbations on LAMA therapy alone and group D COPD with or without inhaled corticosteroids (ICS). Fixed-dose combination (FDC) of aclidinium/formoterol is one of the approved LABA/LAMA therapies for people with stable COPD.

    OBJECTIVES: To assess the efficacy and safety of combined aclidinium bromide and long-acting beta2-agonists in stable COPD.

    SEARCH METHODS: We searched the Cochrane Airways Group Specialised Register (CAGR), ClinicalTrials.gov, World Health Organization (WHO) trials portal, United States Food and Drug Administration (FDA) and manufacturers' websites as well as the reference list of published trials up to 12 October 2018.

    SELECTION CRITERIA: Parallel-group randomised controlled trials (RCTs) assessing combined aclidinium bromide and LABAs in people with stable COPD.

    DATA COLLECTION AND ANALYSIS: We used standard methodological procedures expected by Cochrane for data collection and analysis. The primary outcomes were exacerbations requiring a short course of an oral steroid or antibiotic, or both; quality of life measured by a validated scale and non-fatal serious adverse events (SAEs). Where the outcome or study details were not reported, we contacted the study investigators or pharmaceutical company trial co-ordinators (or both) for missing data.

    MAIN RESULTS: We identified RCTs comparing aclidinium/formoterol FDC versus aclidinium, formoterol or placebo only. We included seven multicentre trials of four to 52 weeks' duration conducted in outpatient settings. There were 5921 participants, whose mean age ranged from 60.7 to 64.7 years, mostly men with a mean smoking pack-years of 46.4 to 61.3 of which 43.9% to 63.4% were current smokers. They had a moderate-to-severe degree of COPD with a mean postbronchodilator forced expiratory volume in one second (FEV1) between 50.5% and 61% of predicted normal and the baseline mean FEV1 of 1.23 L to 1.43 L. We assessed performance and detection biases as low for all studies whereas selection, attrition and reporting biases were either low or unclear.FDC versus aclidiniumThere was no evidence of a difference between FDC and aclidinium for exacerbations requiring steroids or antibiotics, or both (OR 0.95, 95% CI 0.71 to 1.27; 2 trials, 2156 participants; moderate-certainty evidence); quality of life measured by St George's Respiratory Questionnaire (SGRQ) total score (MD -0.92, 95% CI -2.15 to 0.30); participants with significant improvement in SGRQ score (OR 1.17, 95% CI 0.97 to 1.41; 2 trials, 2002 participants; moderate-certainty evidence); non-fatal SAE (OR 1.19, 95% CI 0.79 to 1.80; 3 trials, 2473 participants; moderate-certainty evidence); hospital admissions due to severe exacerbations (OR 0.62, 95% CI 0.29 to 1.29; 2 trials, 2156 participants; moderate-certainty evidence) or adverse events (OR 0.95, 95% CI 0.76 to 1.18; 3 trials, 2473 participants; moderate-certainty evidence). Compared with aclidinium, FDC improved symptoms (Transitional Dyspnoea Index (TDI) focal score: MD 0.37, 95% CI 0.07 to 0.68; 2 trials, 2013 participants) with a higher chance of achieving a minimal clinically important difference (MCID) of at least one unit improvement (OR 1.34, 95% CI 1.11 to 1.62; high-certainty evidence); the number needed to treat for an additional beneficial outcome (NNTB) being 14 (95% CI 9 to 39).FDC versus formoterolWhen compared to formoterol, combination therapy reduced exacerbations requiring steroids or antibiotics, or both (OR 0.78, 95% CI 0.62 to 0.99; 3 trials, 2694 participants; high-certainty evidence); may decrease SGRQ total score (MD -1.88, 95% CI -3.10 to -0.65; 2 trials, 2002 participants; low-certainty evidence; MCID for SGRQ is 4 units); increased TDI focal score (MD 0.42, 95% CI 0.11 to 0.72; 2 trials, 2010 participants) with more participants attaining an MCID (OR 1.30, 95% CI 1.07 to 1.56; high-certainty evidence) and an NNTB of 16 (95% CI 10 to 60). FDC lowered the risk of adverse events compared to formoterol (OR 0.78, 95% CI 0.65 to 0.93; 5 trials, 3140 participants; high-certainty evidence; NNTB 22). However, there was no difference between FDC and formoterol for hospital admissions, all-cause mortality and non-fatal SAEs.FDC versus placeboCompared with placebo, FDC demonstrated no evidence of a difference in exacerbations requiring steroids or antibiotics, or both (OR 0.82, 95% CI 0.60 to 1.12; 2 trials, 1960 participants; moderate-certainty evidence) or hospital admissions due to severe exacerbations (OR 0.55, 95% CI 0.25 to 1.18; 2 trials, 1960 participants; moderate-certainty evidence), although estimates were uncertain. Quality of life measure by SGRQ total score was significantly better with FDC compared to placebo (MD -2.91, 95% CI -4.33 to -1.50; 2 trials, 1823 participants) resulting in a corresponding increase in SGRQ responders who achieved at least four units decrease in SGRQ total score (OR 1.72, 95% CI 1.39 to 2.13; high-certainty evidence) with an NNTB of 7 (95% CI 5 to 12). FDC also improved symptoms measured by TDI focal score (MD 1.32, 95% CI 0.96 to 1.69; 2 studies, 1832 participants) with more participants attaining at least one unit improvement in TDI focal score (OR 2.51, 95% CI 2.02 to 3.11; high-certainty evidence; NNTB 4). There were no differences in non-fatal SAEs, adverse events and all-cause mortality between FDC and placebo.Combination therapy significantly improved trough FEV1 compared to aclidinium, formoterol or placebo.

    AUTHORS' CONCLUSIONS: FDC improved dyspnoea and lung function compared to aclidinium, formoterol or placebo, and this translated into an increase in the number of responders on combination treatment. Quality of life was better with combination compared to formoterol or placebo. There was no evidence of a difference between FDC and monotherapy or placebo for exacerbations, hospital admissions, mortality, non-fatal SAEs or adverse events. Studies reported a lower risk of moderate exacerbations and adverse events with FDC compared to formoterol; however, larger studies would yield a more precise estimate for these outcomes.

    Matched MeSH terms: Forced Expiratory Volume
  9. Ni H, Htet A, Moe S
    Cochrane Database Syst Rev, 2017 Jun 20;6:CD011897.
    PMID: 28631387 DOI: 10.1002/14651858.CD011897.pub2
    BACKGROUND: People with chronic obstructive pulmonary disease (COPD) have poor quality of life, reduced survival, and accelerated decline in lung function, especially associated with acute exacerbations, leading to high healthcare costs. Long-acting bronchodilators are the mainstay of treatment for symptomatic improvement, and umeclidinium is one of the new long-acting muscarinic antagonists approved for treatment of patients with stable COPD.

    OBJECTIVES: To assess the efficacy and safety of umeclidinium bromide versus placebo for people with stable COPD.

    SEARCH METHODS: We searched the Cochrane Airways Group Specialised Register (CAGR), ClinicalTrials.gov, the World Health Organization (WHO) trials portal, and the GlaxoSmithKline (GSK) Clinical Study Register, using prespecified terms, as well as the reference lists of all identified studies. Searches are current to April 2017.

    SELECTION CRITERIA: We included randomised controlled trials (RCTs) of parallel design comparing umeclidinium bromide versus placebo in people with COPD, for at least 12 weeks.

    DATA COLLECTION AND ANALYSIS: We used standard Cochrane methodological procedures. If we noted significant heterogeneity in the meta-analyses, we subgrouped studies by umeclidinium dose.

    MAIN RESULTS: We included four studies of 12 to 52 weeks' duration, involving 3798 participants with COPD. Mean age of participants ranged from 60.1 to 64.6 years; most were males with baseline mean smoking pack-years of 39.2 to 52.3. They had moderate to severe COPD and baseline mean post-bronchodilator forced expiratory volume in one second (FEV1) ranging from 44.5% to 55.1% of predicted normal. As all studies were systematically conducted according to prespecified protocols, we assessed risk of selection, performance, detection, attrition, and reporting biases as low.Compared with those given placebo, participants in the umeclidinium group had a lesser likelihood of developing moderate exacerbations requiring a short course of steroids, antibiotics, or both (odds ratio (OR) 0.61, 95% confidence interval (CI) 0.46 to 0.80; four studies, N = 1922; GRADE: high), but not specifically requiring hospitalisations due to severe exacerbations (OR 0.86, 95% CI 0.25 to 2.92; four studies, N = 1922, GRADE: low). The number needed to treat for an additional beneficial outcome (NNTB) to prevent an acute exacerbation requiring steroids, antibiotics, or both was 18 (95% CI 13 to 37). Quality of life was better in the umeclidinium group (mean difference (MD) -4.79, 95% CI -8.84 to -0.75; three studies, N = 1119), and these participants had a significantly higher chance of achieving a minimal clinically important difference of at least four units in St George's Respiratory Questionnaire (SGRQ) total score compared with those in the placebo group (OR 1.45, 95% CI 1.16 to 1.82; three studies, N = 1397; GRADE: moderate). The NNTB to achieve one person with a clinically meaningful improvement was 11 (95% CI 7 to 29). The likelihood of all-cause mortality, non-fatal serious adverse events (OR 1.33; 95% CI 0.89 to 2.00; four studies, N = 1922, GRADE: moderate), and adverse events (OR 1.06, 95% CI 0.85 to 1.31; four studies, N = 1922; GRADE: moderate) did not differ between umeclidinium and placebo groups. The umeclidinium group demonstrated significantly greater improvement in change from baseline in trough FEV1 compared with the placebo group (MD 0.14, 95% CI 0.12 to 0.17; four studies, N = 1381; GRADE: high). Symptomatic improvement was more likely in the umeclidinium group than in the placebo group, as determined by Transitional Dyspnoea Index (TDI) focal score (MD 0.76, 95% CI 0.43 to 1.09; three studies, N = 1193), and the chance of achieving a minimal clinically important difference of at least one unit improvement was significantly higher with umeclidinium than with placebo (OR 1.71, 95% CI 1.37 to 2.15; three studies, N = 1141; GRADE: high). The NNTB to attain one person with clinically important symptomatic improvement was 8 (95% CI 5 to 14). The likelihood of rescue medication usage (change from baseline in the number of puffs per day) was significantly less for the umeclidinium group than for the placebo group (MD -0.45, 95% CI -0.76 to -0.14; four studies, N = 1531).

    AUTHORS' CONCLUSIONS: Umeclidinium reduced acute exacerbations requiring steroids, antibiotics, or both, although no evidence suggests that it decreased the risk of hospital admission due to exacerbations. Moreover, umeclidinium demonstrated significant improvement in quality of life, lung function, and symptoms, along with lesser use of rescue medications. Studies reported no differences in adverse events, non-fatal serious adverse events, or mortality between umeclidinium and placebo groups; however, larger studies would yield a more precise estimate for these outcomes.

    Matched MeSH terms: Forced Expiratory Volume
  10. Harun SN, Wainwright CE, Grimwood K, Hennig S, Australasian Cystic Fibrosis Bronchoalveolar Lavage (ACFBAL) study group
    Thorax, 2019 02;74(2):125-131.
    PMID: 30275132 DOI: 10.1136/thoraxjnl-2018-211550
    BACKGROUND: The impact of Aspergillus on lung disease in young children with cystic fibrosis is uncertain.
    AIMS: To determine if positive respiratory cultures of Aspergillus species are associated with: (1) increased structural lung injury at age 5 years; (2) accelerated lung function decline between ages 5 years and 14 years and (3) to identify explanatory variables.
    METHODS: A cross-sectional analysis of association between Aspergillus positive bronchoalveolar lavage (BAL) cultures and chest high-resolution CT (HRCT) scan findings at age 5 years in subjects from the Australasian Cystic Fibrosis Bronchoalveolar Lavage (ACFBAL) study was performed. A non-linear mixed-effects disease progression model was developed using FEV1% predicted measurements at age 5 years from the ACFBAL study and at ages 6-14 years for these subjects from the Australian Cystic Fibrosis Data Registry.
    RESULTS: Positive Aspergillus BAL cultures at age 5 years were significantly associated with increased HRCT scores for air trapping (OR 5.53, 95% CI 2.35 to 10.82). However, positive Aspergillus cultures were not associated with either FEV1% predicted at age 5 years or FEV1% predicted by age following adjustment for body mass index z-score and hospitalisation secondary to pulmonary exacerbations. Lung function demonstrated a non-linear decline in this population.
    CONCLUSION: In children with cystic fibrosis, positive Aspergillus BAL cultures at age 5 years were associated contemporaneously with air trapping but not bronchiectasis. However, no association was observed between positive Aspergillus BAL cultures on FEV1% predicted at age 5 years or with lung function decline between ages 5 years and 14 years.
    Matched MeSH terms: Forced Expiratory Volume
  11. Mohktar MS, Redmond SJ, Antoniades NC, Rochford PD, Pretto JJ, Basilakis J, et al.
    Artif Intell Med, 2015 Jan;63(1):51-9.
    PMID: 25704112 DOI: 10.1016/j.artmed.2014.12.003
    BACKGROUND: The use of telehealth technologies to remotely monitor patients suffering chronic diseases may enable preemptive treatment of worsening health conditions before a significant deterioration in the subject's health status occurs, requiring hospital admission.
    OBJECTIVE: The objective of this study was to develop and validate a classification algorithm for the early identification of patients, with a background of chronic obstructive pulmonary disease (COPD), who appear to be at high risk of an imminent exacerbation event. The algorithm attempts to predict the patient's condition one day in advance, based on a comparison of their current physiological measurements against the distribution of their measurements over the previous month.
    METHOD: The proposed algorithm, which uses a classification and regression tree (CART), has been validated using telehealth measurement data recorded from patients with moderate/severe COPD living at home. The data were collected from February 2007 to January 2008, using a telehealth home monitoring unit.
    RESULTS: The CART algorithm can classify home telehealth measurement data into either a 'low risk' or 'high risk' category with 71.8% accuracy, 80.4% specificity and 61.1% sensitivity. The algorithm was able to detect a 'high risk' condition one day prior to patients actually being observed as having a worsening in their COPD condition, as defined by symptom and medication records.
    CONCLUSION: The CART analyses have shown that features extracted from three types of physiological measurements; forced expiratory volume in 1s (FEV1), arterial oxygen saturation (SPO2) and weight have the most predictive power in stratifying the patients condition. This CART algorithm for early detection could trigger the initiation of timely treatment, thereby potentially reducing exacerbation severity and recovery time and improving the patient's health. This study highlights the potential usefulness of automated analysis of home telehealth data in the early detection of exacerbation events among COPD patients.
    Matched MeSH terms: Forced Expiratory Volume
  12. Sui CF, Ming LC, Neoh CF, Ibrahim B
    PMID: 26316735 DOI: 10.2147/COPD.S84618
    Background: This study utilized a validated combination of a COPD Population Screener
    (COPD-PS) questionnaire and a handheld spirometric device as a screening tool for patients at high risk of COPD, such as smokers. The study aimed to investigate and pilot the feasibility and application of this combined assessment, which we termed the “VitalQPlus”, as a screening tool for the early detection of COPD, especially in primary care settings.
    Methods: This was a cross-sectional study screening potentially undiagnosed COPD patients using a validated five-item COPD-PS questionnaire together with a handheld spirometric device. Patients were recruited from selected Malaysian government primary care health centers.
    Results: Of the total of 83 final participants, only 24.1% (20/83) were recruited from Perak and Penang (peninsular Malaysia) compared to 75.9% (63/83) from Sabah (Borneo region). Our dual assessment approach identified 8.4% of the surveyed patients as having potentially undiagnosed COPD. When only the Vitalograph COPD-6 screening tool was used, 15.8% of patients were detected with a forced expiratory volume in 1 second/forced expiratory volume in 6 seconds (FEV1/FEV6) ratio at <0.75, while 35.9% of patients were detected with the COPD-PS questionnaire. These findings suggested that this dual assessment approach has a greater chance of identifying potentially undiagnosed COPD patients compared to the Vitalograph COPD-6 or COPD-PS questionnaire when used alone. Our findings show that patients with more symptoms (scores of >=5) yielded twice the percentage of outcomes of FEV1/FEV6 <0.75 compared to patients with fewer COPD symptoms (scores <5).
    Conclusion: With the availability of a simple screening questionnaire and the COPD-6, there is an opportunity easily to make patients more aware of their lung symptoms and to encourage the provision of early treatment. The proposed dual assessment approach, which we termed the VitalQPlus, may play a profound role in the early diagnosis of COPD, which is crucial in improving the clinical management of the disease.
    Keywords: spirometry, pulmonary function test, chronic obstructive pulmonary disease,
    airway obstruction
    Matched MeSH terms: Forced Expiratory Volume
  13. Chai CS, Liam CK, Pang YK, Ng DL, Tan SB, Wong TS, et al.
    Int J Chron Obstruct Pulmon Dis, 2019 03 01;14:565-573.
    PMID: 30880946 DOI: 10.2147/COPD.S196109
    Introduction: The Spanish COPD guideline (GesEPOC) classifies COPD into four clinical phenotypes based on the exacerbation frequency and dominant clinical manifestations. In this study, we compared the disease-specific health-related quality of life (HRQoL) of patients with different clinical phenotypes.

    Methods: This was a cross-sectional study of patients with COPD attending the respiratory medicine clinic of University of Malaya Medical Centre from 1 June 2017 to 31 May 2018. Disease-specific HRQoL was assessed by using the COPD Assessment Test (CAT) and St George's Respiratory Questionnaire for COPD (SGRQ-c).

    Results: Of 189 patients, 28.6% were of non-exacerbator phenotype (NON-AE), 18.5% were of exacerbator with emphysema phenotype (AE NON-CB), 39.7% were of exacerbator with chronic bronchitis phenotype (AE CB), and 13.2% had asthma-COPD overlap syndrome phenotype (ACOS). The total CAT and SGRQ-c scores were significantly different between the clinical phenotypes (P<0.001). Patients who were AE CB had significantly higher total CAT score than those with ACOS (P=0.033), AE NON-CB (P=0.001), and NON-AE (P<0.001). Concerning SGRQ-c, patients who were AE CB also had a significantly higher total score than those with AE NON-CB (P=0.001) and NON-AE (P<0.001). However, the total SGRQ-c score of AE CB patients was only marginally higher than those who had ACOS (P=0.187). There was a significant difference in the score of each CAT item (except CAT 7) and SGRQ-c components between clinical phenotypes, with AE CB patients recording the highest score in each of them.

    Conclusion: Patients who were AE CB had significantly poorer HRQoL than other clinical phenotypes and recorded the worst score in each of the CAT items and SGRQ-c components. Therefore, AE CB patients may warrant a different treatment approach that focuses on the exacerbation and chronic bronchitis components.

    Matched MeSH terms: Forced Expiratory Volume
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links