Displaying publications 81 - 100 of 151 in total

Abstract:
Sort:
  1. Lai CS, Nair NK, Muniandy A, Mansor SM, Olliaro PL, Navaratnam V
    J Chromatogr B Analyt Technol Biomed Life Sci, 2009 Feb 15;877(5-6):558-62.
    PMID: 19147417 DOI: 10.1016/j.jchromb.2008.12.037
    With the expanded use of the combination of artesunate (AS) and amodiaquine (AQ) for the treatment of falciparum malaria and the abundance of products on the market, comes the need for rapid and reliable bioanalytical methods for the determination of the parent compounds and their metabolites. While the existing methods were developed for the determination of either AS or AQ in biological fluids, the current validated method allows simultaneous extraction and determination of AS and AQ in human plasma. Extraction is carried out on Supelclean LC-18 extraction cartridges where AS, its metabolite dihydroartemisinin (DHA) and the internal standard artemisinin (QHS) are separated from AQ, its metabolite desethylamodiaquine (DeAQ) and the internal standard, an isobutyl analogue of desethylamodiaquine (IB-DeAQ). AS, DHA and QHS are then analysed using Hypersil C4 column with acetonitrile-acetic acid (0.05M adjusted to pH 5.2 with 1.00M NaOH) (42:58, v/v) as mobile phase at flow rate 1.50ml/min. The analytes are detected with an electrochemical detector operating in the reductive mode. Chromatography of AQ, DeAQ and IB-DeAQ is carried out on an Inertsil C4 column with acetonitrile-KH(2)PO(4) (pH 4.0, 0.05M) (11:89, v/v) as mobile phase at flow rate 1.00ml/min. The analytes are detected by an electrochemical detector operating in the oxidative mode. The recoveries of AS, DHA, AQ and DeAQ vary between 79.1% and 104.0% over the concentration range of 50-1400ng/ml plasma. The accuracies of the determination of all the analytes are 96.8-103.9%, while the variation for within-day and day-to-day analysis are <15%. The lower limit of quantification for all the analytes is 20ng/ml and limit of detection is 8ng/ml. The method is sensitive, selective, accurate, reproducible and suited particularly for pharmacokinetic study of AS-AQ drug combination and can also be used to compare the bioavailability of different formulations, including a fixed-dose AS-AQ co-formulation.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  2. Hadi H, Makahleh A, Saad B
    PMID: 22503735 DOI: 10.1016/j.jchromb.2012.03.031
    A hollow fiber liquid phase microextraction (HF-LPME) in conjunction with reversed phase HPLC-UV method was developed for the extraction and determination of trace amounts of the antidiabetic drug, mitiglinide (MIT) in biological fluids. The drug was extracted from 10 mL aqueous sample (donor phase (DP)) into an organic phase impregnated in the pores of hollow fiber, followed by the back extraction into a second aqueous solution (acceptor phase (AP)) located in the lumen of the hollow fiber. Parameters influencing the extraction efficiency including the kind of organic solvent, composition of DP and AP, extraction time, stirring rate and salt addition were investigated and optimized. Under the optimized extraction conditions, high enrichment factors (210-fold), good linearity (5-1000 ng mL(-1)) and detection limit lower than 1.38 ng mL(-1) were achieved. Recoveries of spiked samples were in the range (88.3-96.3%) and (92.0-99.3%) for urine and plasma samples, respectively. The percent relative standard deviation (n=9) for the extraction and determination of three concentration levels (100, 400 and 800 ng mL(-1)) of MIT were less than 10.6% and 13.6% for urine and plasma samples, respectively. The developed method is simple, sensitive and has been successfully applied to the analysis of MIT in biological fluids.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  3. Tan KL, Ankathil R, Gan SH
    J Chromatogr B Analyt Technol Biomed Life Sci, 2011 Nov 15;879(30):3583-91.
    PMID: 22000961 DOI: 10.1016/j.jchromb.2011.09.048
    We developed a simple and sensitive method for the simultaneous detection of imatinib mesylate (IM) and its active metabolite, N-desmethyl imatinib (M1), in human serum samples. Separation was successfully achieved using an Agilent(®) ZORBAX Eclipse plus C(18) reversed phase column (50 mm × 2.1 mm, i.d.; 1.8 μm) under isocratic mobile phase conditions consisting of acetonitrile: 0.02 M potassium dihydrogen phosphate with 0.2% triethylamine at pH 3 (25:75, v/v) and ultra-violet detection was achieved at 235 nm. Extraction of the target compounds was completed using 100% cold acetonitrile. Good linearities (r(2)>0.99) for both IM and M1 were achieved for the concentration ranges of 50-1800 ng/mL and 50-360 ng/mL, respectively. The detection limits were 20 ng/mL and 10 ng/mL for M1 and IM, respectively. The intra- and inter-day precisions were less than 1% with percent recoveries of more than 90%. The method was successfully applied to calculate the pharmacokinetic parameters of chronic myeloid leukemia patients receiving imatinib. The method is suitable to be routinely applied for determination of IM and M1 in serum.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  4. Gan SH, Ismail R, Wan Adnan WA, Wan Z
    PMID: 12016023
    An HPLC system using a simple liquid-liquid extraction and HPLC with UV detection has been validated to determine tramadol concentration in human plasma. The method developed was selective and linear for concentrations ranging from 10 to 2000 ng/ml with average recovery of 98.63%. The limit of quantitation (LOQ) was 10 ng/ml and the percentage recovery of the internal standard phenacetin was 76.51%. The intra-day accuracy ranged from 87.55 to 105.99% and the inter-day accuracy, 93.44 to 98.43% for tramadol. Good precision (5.32 and 6.67% for intra- and inter-day, respectively) was obtained at LOQ. The method has been applied to determine tramadol concentrations in human plasma samples for a pharmacokinetic study.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  5. Mohamad Hanapi NS, Sanagi MM, Ismail AK, Wan Ibrahim WA, Saim N, Wan Ibrahim WN
    PMID: 28142101 DOI: 10.1016/j.jchromb.2017.01.028
    The aim of this study was to investigate and apply supported ionic liquid membrane (SILM) in two-phase micro-electrodriven membrane extraction combined with high performance liquid chromatography-ultraviolet detection (HPLC-UV) for pre-concentration and determination of three selected antidepressant drugs in water samples. A thin agarose film impregnated with 1-hexyl-3-methylimidazolium hexafluorophosphate, [C6MIM] [PF6], was prepared and used as supported ionic liquid membrane between aqueous sample solution and acceptor phase for extraction of imipramine, amitriptyline and chlorpromazine. Under the optimized extraction conditions, the method provided good linearity in the range of 1.0-1000μgL(-1), good coefficients of determination (r(2)=0.9974-0.9992) and low limits of detection (0.1-0.4μgL(-1)). The method showed high enrichment factors in the range of 110-150 and high relative recoveries in the range of 88.2-111.4% and 90.9-107.0%, for river water and tap water samples, respectively with RSDs of ≤7.6 (n=3). This method was successfully applied to the determination of the drugs in river and tap water samples. It is envisaged that the SILM improved the perm-selectivity by providing a pathway for targeted analytes which resulted in rapid extraction with high degree of selectivity and high enrichment factor.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  6. Sim YS, Chong ZY, Azizi J, Goh CF
    PMID: 35700649 DOI: 10.1016/j.jchromb.2022.123316
    Mitragynine is a promising candidate for pain relief and opiate replacement but the investigations for drug delivery are lacking. This study aims to investigate the potential of mitragynine to be delivered through the skin with an emphasis on developing and validating a gradient HPLC-UV analytical method to determine mitragynine in the samples collected during in vitro skin permeation studies. The optimised method involves a gradient elution using a C18 column with a mobile phase comprising acetonitrile and 0.1 %v/v of formic acid (0-1 min: 30:70 to 70:30 (v/v) and hold up to 4 min; 4-6 min: return to 30:70 (v/v) and hold up to 10 min) at a flow rate of 1.2 mL/min. This method was validated based on the standards set by the International Council on Harmonisation guidelines. The method showed mitragynine elution at ∼ 4 min with adequate linearity (R2 ≥ 0.999 for concentration ranges of 0.5-10 and 10-175 μg/mL) and acceptable limits of detection and quantification at 0.47 and 1.43 μg/mL, respectively. The analytical performance is robust with excellent precision and accuracy. This method was used to evaluate the in vitro skin permeation of mitragynine (5 %w/v) from simple solvent systems over 48 hr. The results showed a cumulative amount of mitragynine permeated at ∼ 11 μg/cm2 for dimethyl sulfoxide and ∼ 4 μg/cm2 for propylene glycol. The study not only addressed the issues of the currently available HPLC-UV methods that limit the direct application but also affirmed the potential of mitragynine to be delivered through the skin.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  7. Najmul Hejaz Azmi S, Aqib Nasir Al Rawahi W, Ibrahim Al Yahyai A, Ali Al Qasimi A, Saif Al Fuliti K, Said Al Qalhati O, et al.
    PMID: 38309045 DOI: 10.1016/j.jchromb.2024.124035
    A UV-HPLC method optimized by Box-Behnken design model was developed to determine caffeine in pharmaceutical preparations and urine samples. The chromatographic conditions followed were mobile phase: methanol/water/ citrate buffer (pH 4.6) (40:25:35, v/v/v),AcclaimTMDionex C18 column (ODS 100A˚, 5 µm; 4.6 × 250 mm),flow rate (0.9 mL min-1), column temperature (30 °C) and UV-detection wavelength (204 nm). The chromatographic variables: pH (A), % methanol fraction (B), flow rate(C) and column temperature (D) were optimized at 50 μg mL-1caffeine using BBD model. The chromatogram resulted in the asymmetry factor (1.23), theoretical plate 13,786 and retention time (5.79 min). The proposed HPLC method's greenness point was assessed byAnalytical Eco-scale and found to be 78 (as per guidelines, ranked as excellent). The linearity was ranged from2.0 to 70 µg mL-1 with coefficient of correlation (r = 0.999) and detection limit of 0.19 µg mL-1. The proposedmethod was developed successfully and applied for the assay of active caffeine in pharmaceutical preparations and urine samples. The % recovery obtained by both (proposed and reference) methods ranged from 99.98 to 100.05 % followed the compliance (100 ± 2 %) with Canadian Health Protection regulatory guidelines. The performance of the proposed method was compared with published papers and found to be acceptable and superior. The proposed method was quite effective as the reference method, and hence can be used as an alternative method for the assay of active caffeine in pharmaceutical preparations and urine samples.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  8. Navaratnam V, Mansor SM, Chin LK, Mordi MN, Asokan M, Nair NK
    J Chromatogr B Biomed Appl, 1995 Jul 21;669(2):289-94.
    PMID: 7581905
    A selective reproducible high-performance liquid chromatographic assay for the simultaneous quantitative determination of the antimalarial compound artemether (ARM), dihydroartemisinin (DQHS) and artemisinin (QHS), as internal standard, is described. After extraction from plasma, ARM and DQHS were analysed using a Lichrocart/Lichrosphere 100 CN stainless-steel column and a mobile phase of acetonitrile-0.05 M acetic acid (15:85, v/v) adjusted to pH 5.0, and electrochemical detection in the reductive mode. The mean recovery of ARM and DQHS over a concentration range of 30-120 ng/ml was 81.6% and 93.4%, respectively. The within-day coefficients of variation were 0.89-7.01% for ARM and 3.45-8.11% for DQHS. The day-to-day coefficients of variation were 2.06-8.43% and 3.22-6.33%, respectively. The minimum detectable concentration for ARM and DQHS in plasma was 2.5 and 1.25 ng/ml for both compounds. The method was found to be suitable for use in clinical pharmacological studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  9. Mansor SM, Navaratnam V, Yahaya N, Nair NK, Wernsdorfer WH, Degen PH
    J Chromatogr B Biomed Appl, 1996 Jul 12;682(2):321-5.
    PMID: 8844426
    A rapid and selective high-performance liquid chromatographic assay for determination of a new antimalarial drug (benflumetol, BFL) is described. After extraction with hexane-diethyl ether (70:30, v/v) from plasma, BFL was analysed using a C18 Partisil 10 ODS-3 reversed-phase stainless steel column and a mobile phase of acetonitrile-0.1 M ammonium acetate (90:10, v/v) adjusted to pH 4.9 with ultraviolet detection at 335 nm. The mean recovery of BFL over a concentration range of 50-400 ng/ml was 96.8 +/- 5.2%. The within-day and day-to-day coefficients of variation were 1.8-4.0 and 1.8-4.2%, respectively. The minimum detectable concentration in plasma for BFL was 5 ng/ml with a C.V. of less than 10%. This method was found to be suitable for clinical pharmacokinetic studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  10. Ramanathan S, Nair NK, Mansor SM, Navaratnam V
    J Chromatogr B Biomed Appl, 1994 May 13;655(2):269-73.
    PMID: 8081473
    A rapid and selective high-performance liquid chromatographic (HPLC) method for the simultaneous determination of the antifilarial drug UMF-078 (I) and its metabolites UMF-060 (II) and flubendazole (III) is described. After a simple extraction from whole blood, the compounds were determined by HPLC using a C18 Inertsil ODS-2 reversed-phase column with methanol-0.05M ammonium acetate (pH 4.0) as the mobile phase and ultraviolet detection at 291 nm. The average recoveries of I, II and III over the concentration range 20-500 ng ml-1 were 69.9 +/- 4.7, 85.6 +/- 4.4 and 85.1 +/- 6.0%, respectively. The minimum detectable concentrations in whole blood for I, II and III were 10, 7 and 7 ng ml-1, respectively. This method was found to be suitable for pharmacokinetic studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  11. Gan SH, Ismail R
    J Chromatogr B Biomed Sci Appl, 2001 Aug 15;759(2):325-35.
    PMID: 11499486
    An HPLC system using solid-phase extraction and HPLC with UV detection has been validated in order to determine tramadol and o-desmethyltramadol (M1) concentrations in human plasma. The method developed was selective and linear for concentrations ranging from 50 to 3,500 ng/ml (tramadol) and 50 to 500 ng/ml (M1) with mean recoveries of 94.36 +/- 12.53% and 93.52 +/- 7.88%, respectively. Limit of quantitation (LOQ) was 50 ng/ml. For tramadol, the intra-day accuracy ranged from 95.48 to 114.64% and the inter-day accuracy, 97.21 to 103.24%. Good precision (0.51 and 18.32% for intra- and inter-day, respectively) was obtained at LOQ. The system has been applied to determine tramadol concentrations in human plasma samples for a pharmacokinetic study.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  12. Cheah PY, Yuen KH, Liong ML
    J Chromatogr B Biomed Sci Appl, 2000 Aug 18;745(2):439-43.
    PMID: 11043762
    A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method was developed for the determination of terazosin in human plasma. The method involves a one-step single solvent extraction procedure using dichloromethane with a 0.25 ml plasma sample. Recovery values were all greater than 90% over the concentration range 0.25-100 ng/ml. Terazosin was found to adsorb to glass or plastic tubes, but this could be circumvented by using disposable plastic tubes. Also, rinsing the injector port with methanol after each injection helped to prevent any carry-over effect. The internal standard, prazosin, did not exhibit this problem. The method has a quantification limit of 0.25 ng/ml. The within- and between-day coefficient of variation and accuracy values were all less than 7% over the concentration range 0.25-100 ng/ml and hence the method is suitable for use in pharmacokinetic studies of terazosin.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  13. Xu ZQ, Norris KJ, Weinberg DS, Kardatzke J, Wertz P, Frank P, et al.
    J Chromatogr B Biomed Sci Appl, 2000 Jun 09;742(2):267-75.
    PMID: 10901131
    A HPLC method was validated for quantification of (+)-calanolide A (1), a novel anti-HIV agent, in rat, dog and human plasma. The synthetic intermediate (+/-)-12-oxocalanolide A (2) was found to be a suitable internal standard. Compounds were extracted from plasma using a solid-phase C(18) cartridge and quantified over the assay range of 12.5 to 800 ng/ml. The method was utilized to determine (+)-calanolide A pharmacokinetics in rats, dogs and humans. This is the first report of a validated HPLC assay for determination of (+)-calanolide A concentrations in rat and dog plasma as well as human plasma obtained from clinical trials. There was no evidence of in vivo epimerization of (+)-calanolide A to its inactive epimer (+)-calanolide B (3).
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  14. Yap SP, Julianto T, Wong JW, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1999 Dec 10;735(2):279-83.
    PMID: 10670741
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of vitamin E especially delta-, gamma- and alpha-tocotrienols in human plasma. The method entailed direct injection of plasma sample after deproteinization using a 3:2 mixture of acetonitrile-tetrahydrofuran. The mobile phase comprised 0.5% (v/v) of distilled water in methanol. Analyses were run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 296 nm and emission wavelength of 330 nm. This method is specific and sensitive, with a quantification limit of approximately 40, 34 and 16 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. The mean absolute recovery values were about 98% while the within-day and between-day relative standard deviation and percent error values of the assay method were all less than 12.0% for alpha-, gamma- and delta-tocotrienol. The calibration curve was linear over a concentration range of 40-2500, 30-4000 and 16-1000 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. Application of the method in a bioavailability study for determination of the above compounds was also demonstrated.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  15. Kah Hay Yuen, Kok Khiang Peh
    J Chromatogr B Biomed Sci Appl, 1998 Jun 12;710(1-2):243-6.
    PMID: 9686895
    A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of metformin in human plasma. The method entailed direct injection of the plasma sample after deproteination using perchloric acid. The mobile phase comprised 0.01 M potassium dihydrogen orthophosphate (pH 3.5) and acetonitrile (60:40, v/v). Analyses were run at a flow-rate of 1.0 ml/min with the detector operating at a detection wavelength of 234 nm. The method is specific and sensitive, with a quantification limit of approximately 60 ng/ml and a detection limit of 15 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery value was about 97%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 8%. The calibration curve was linear over a concentration range of 62.5-4000 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  16. Julianto T, Yuen KH, Noor AM
    J Chromatogr B Biomed Sci Appl, 1999 Sep 10;732(1):227-31.
    PMID: 10517240
    A simple high-performance liquid chromatographic method using UV detection was developed for the determination of alpha-tocopherol in human plasma. The method entailed direct injection of the plasma sample after deproteinization using acetonitrile-tetrahydrofuran (3:2). The mobile phase comprised methanol-tetrahydrofuran (94:6) and analysis was run at a flow-rate of 1.5 ml/min with the detector operating at 292 nm. A Crestpak C18S (5 microm, 250 mm x 4.6 mm ID) was used for the chromatographic separation. The method had a mean recovery of 93%, while the within-day and between-day coefficients of variation and percentage errors were all less than 7%. The speed, specificity, sensitivity and reproducibility of this method make it particularly suitable for routine determination of alpha-tocopherol in human plasma. Moreover, only a small sample plasma volume (100 microl) is required for the analysis.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  17. Wong CF, Peh KK, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1998 Oct 23;718(1):205-10.
    PMID: 9832378
    A simple high-performance liquid chromatographic method was developed for the determination of ranitidine in human plasma. Prior to analysis, ranitidine and the internal standard (metoprolol) were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M potassium dihydrogenphosphate-acetonitrile (88:12, v/v) adjusted to pH 6.5. Analysis was run at a flow-rate of 1.3 ml/min and at a detection wavelength of 229 nm. The method is sensitive with a detection limit of 1 ng/ml at a signal-to-noise ratio of 3:1, while the quantification limit was set at 15 ng/ml. The calibration curve was linear over a concentration range of 15-2000 ng/ml. Mean recovery value of the extraction procedure was about 90%, while the within-day and between-day coefficients of variation and percent error values of the assay method were all less than 15%.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  18. Jia Woei Wong, Kah Hay Yuen, Kok Khiang Peh
    J Chromatogr B Biomed Sci Appl, 1998 Sep 25;716(1-2):387-91.
    PMID: 9824257
    A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of pentoxifylline in human plasma. Prior to analysis, pentoxifylline and the internal standard (chloramphenicol) were extracted from plasma sample using dichloromethane. The mobile phase comprised 0.02 M phosphoric acid adjusted to pH 4, methanol and tetrahydrofuran (55:45:1, v/v). Analysis was run at a flow-rate of 1.4 ml/min with the detector operated at a wavelength of 273 nm. The method was specific and sensitive with a detection limit of approximately 3.0 ng/ml at a signal to noise ratio of 3:1, while the limit of quantification was 12.5 ng/ml. Mean recovery value of the extraction procedure was about 99.9%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 10.0%. The calibration curve was linear over a concentration range of 12.5-400.0 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  19. Yuen KH, Peh KK
    J Chromatogr B Biomed Sci Appl, 1998 Sep 18;715(2):436-40.
    PMID: 9792531
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of ketoconazole in human plasma. The method entailed direct injection of the plasma sample after deproteinization using acetonitrile. The mobile phase comprised 0.05 M disodium hydrogen orthophosphate and acetonitrile (50:50, v/v) adjusted to pH 6. Analysis was run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 260 nm and an emission wavelength of 375 nm. The method is specific and sensitive with a quantification limit of approximately 60 ng/ml and a detection limit of 40 ng/ml at a signal-to-noise ratio of 3:1. Mean absolute recovery value was about 105%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 14%. The calibration curve was linear over a concentration range of 62.5-8000 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  20. Abdullah N, Goh YX, Othman R, Ismail N, Jalal N, Wan Sallam WAF, et al.
    J Clin Lab Anal, 2023 Apr;37(8):e24898.
    PMID: 37243371 DOI: 10.1002/jcla.24898
    OBJECTIVE: Glycated haemoglobin (HbA1c) is a standard indication for screening type 2 diabetes that also has been widely used in large-scale epidemiological studies. However, its long-term quality (in terms of reproducibility) stored in liquid nitrogen is still unknown. This study is aimed to evaluate the stability and reproducibility of HbA1c measurements from frozen whole blood samples kept at -196°C for more than 7 years.

    METHODS: A total of 401 whole blood samples with a fresh HbA1c measurement were randomly selected from The Malaysian Cohort's (TMC) biobank. The HbA1c measurements of fresh and frozen (stored for 7-8 years) samples were assayed using different high-performance liquid chromatography (HPLC) systems. The HbA1c values of the fresh samples were then calculated and corrected according to the later system. The reproducibility of HbA1c measurements between calculated-fresh and frozen samples was assessed using a Passing-Bablok linear regression model. The Bland-Altman plot was then used to evaluate the concordance of HbA1c values.

    RESULTS: The different HPLC systems highly correlated (r = 0.99) and agreed (ICC = 0.96) with each other. Furthermore, the HbA1c measurements for frozen samples strongly correlate with the corrected HbA1c values of the fresh samples (r = 0.875) with a mean difference of -0.02 (SD: -0.38 to 0.38). Although the mean difference is small, discrepancies were observed within the diabetic and non-diabetic samples.

    CONCLUSION: These data demonstrate that the HbA1c measurements between fresh and frozen samples are highly correlated and reproducible.

    Matched MeSH terms: Chromatography, High Pressure Liquid/methods