Displaying publications 81 - 100 of 1293 in total

Abstract:
Sort:
  1. Vythilingam I, Zainal AR, Hamidah T
    PMID: 10695808
    Two formulations of lambda-cyhalothrin (EC-Emulsion concentrate and MC-Microencapsulated) were impregnated into bednets made of polyethylene and polyester. The nets were treated at a dosage of 15 mg/m2. For bioassay of insecticidal efficacy, female Anopheles maculatus and Aedes aegypti were exposed to the nets for two minutes and mortality was scored 24 hours later. The nets were also tested after repeated washings with water and with soap and water. Microencapsulated (2.5CS) formulation was more effective than emulsion concentrate (2.5EC) formulation on both net materials--polyethylene and polyester. Repeated washing with water and soap reduces the efficacy of all bednet treatment combinations. Microencapsulated formulation on polyethylene gave best results; it could sustain up to five washes with water and two with soap and water.
    Matched MeSH terms: Microscopy, Electron, Scanning
  2. Eng KL, Chiang GL, Hamidah T, Loong KP
    PMID: 1976273
    Descriptions of the eggs of Mansonia uniformis, Ma. indiana and Ma. annulifera are provided with the aid of scanning electron micrographs. Eggs of these three species, although similar in shape and colour, are covered by outer chorionic reticulum and tubercles which provide reliable morphological character for their identification. Size, distribution and number of lobes on the large tubercles present in the region between the anterior tube and posterior region, are important distinguishing features. Measurements of egg sizes and other chorionic differences are also discussed.
    Matched MeSH terms: Microscopy, Electron, Scanning
  3. Phansri W, Ow-Yang CK, Lai PF, Greer GJ
    PMID: 6535267
    Matched MeSH terms: Microscopy, Electron, Scanning
  4. Samah NA, Sánchez-Martín MJ, Sebastián RM, Valiente M, López-Mesas M
    Sci Total Environ, 2018 Aug 01;631-632:1534-1543.
    PMID: 29727977 DOI: 10.1016/j.scitotenv.2018.03.087
    Contaminants of Emerging Concerns (CECs) have been introduced as one type of recalcitrant pollutant sources in water. In this study, the non-steroidal anti-inflammatory drug diclofenac (DCF) has been removed from water solutions using Molecularly Imprinted Polymer (MIP), synthetized via bulk polymerization with allylthiourea (AT) as the functional monomer and using DCF as template (MIP-DCF). DCF detection has been performed by UV spectrophotometer. From the kinetic study in batch mode, approximately 100% of removal is observed by using 10mg of MIP-DCF, with an initial concentration of 5mg/L of DCF at pH7, within 3min and agitated at 25°C. In continuous flow mode study, using a cartridge pre-packed with 10mg of MIP-DCF, a high adsorption capacity of 160mgDCF/g MIP was obtained. To study the porosity of MIPs, scanning electron microscopy (SEM) has been used. In order to characterize the chemical interaction between monomer and template, the pre-polymerization mixture for MIP and DCF has also been studied by 1H NMR. One of the chemical shift observed has been related to the formation of a complex between amine protons of thiourea group of AT with carboxylic acid on DCF. In conclusion, the developed MIP works as a good adsorbent for DCF removal, and is selective to DCF in the presence of indomethacin and ibuprofen.
    Matched MeSH terms: Microscopy, Electron, Scanning
  5. Meng Y, Ling TC, Mo KH, Tian W
    Sci Total Environ, 2019 Jun 25;671:827-837.
    PMID: 30947055 DOI: 10.1016/j.scitotenv.2019.03.411
    Carbonation for the curing of cement-based materials has been gaining increased attention in recent years, especially in light of emerging initiatives to reduce carbon dioxide (CO2) emissions. Carbonation method or CO2 curing is founded on the basis of the reaction between CO2 and cement products to form thermally stable and denser carbonate, which not only improves the physical and mechanical properties of cement-based materials, but also has the ability to utilize and store CO2 safely and permanently. This study aims to assess the effect of CO2 curing technology on the high-temperatures performance of cement blocks. Upon molding, dry-mix cement blocks were cured under statically accelerated carbonation condition (20% CO2 concentration with 70% relative humidity) for 28 days, followed by exposure to elevated temperatures of 300 °C to 800 °C in order to comprehensively study the principal phase changes and decompositions of cement hydrates. The results indicated that CO2 curing improved the performance of cement blocks, such as enhancement in the residual compressive strength and reducing the sorptivity. At 600 °C, the scanning electron microscopy (SEM) revealed a denser microstructure while thermal analisis and X-ray diffraction (XRD) analysis also clearly demonstrated that higher amounts of calcium carbonate were present in the cement blocks after CO2 curing, suggesting better high-temperature performance compared to natural cured cement blocks. In general, an improved high-temperature performance, specifically at 600 °C of the dry-mixed cement blocks was demonstrated by adopting the CO2 curing technology. This confirms the potential of utilizing CO2 curing technology in not only improving quality of cement blocks, new avenue for storing of CO2 in construction material can be realized at the same time.
    Matched MeSH terms: Microscopy, Electron, Scanning
  6. Akinyemi SA, Gitari WM, Petrik LF, Nyakuma BB, Hower JC, Ward CR, et al.
    Sci Total Environ, 2019 May 01;663:177-188.
    PMID: 30711584 DOI: 10.1016/j.scitotenv.2019.01.308
    Coal combustion and the disposal of combustion wastes emit enormous quantities of nano-sized particles that pose significant health concerns on exposure, particularly in unindustrialized countries. Samples of fresh and weathered class F fly ash were analysed through various techniques including X-ray fluorescence (XRF), X-ray diffraction (XRD), focused ion beam scanning electron microscopy (FIB-SEM), field-emission gun scanning electron microscopy (FE-SEM), high-resolution transmission electron microscopy (HR-TEM) coupled with energy dispersive x-ray spectroscopy (EDS), and Raman Spectroscopy. The imaging techniques showed that the fresh and weathered coal fly ash nanoparticles (CFA-NPs) are mostly spherical shaped. The crystalline phases detected were quartz, mullite, ettringite, calcite, maghemite, hematite, gypsum, magnetite, clay residues, and sulphides. The most abundant crystalline phases were quartz mixed with Al-Fe-Si-K-Ti-O-amorphous phases whereas mullite was detected in several amorphous phases of Al, Fe, Ca, Si, O, K, Mg, Mn, and P. The analyses revealed that CFA-NPs are 5-500 nm in diameter and encapsulate several potentially hazardous elements (PHEs). The carbon species were detected as 5-50 nm carbon nanoballs of graphitic layers and massive fullerenes. Lastly, the aspects of health risks related to exposure to some detected ambient nanoparticles are also discussed.
    Matched MeSH terms: Microscopy, Electron, Scanning; Microscopy, Electron, Transmission
  7. Abdulkader YC, Kamaruddin AF, Mydin RBSMN
    Saudi Dent J, 2020 Sep;32(6):306-313.
    PMID: 32874071 DOI: 10.1016/j.sdentj.2019.09.010
    Objectives: This study compared the effects of normal salivary pH, and acidic pH found in patients with poor oral hygiene, on the durability of aesthetic archwire coated with epoxy resin and polytetrafluoroethylene (PTFE).

    Methods: The posterior parts of the archwires were sectioned into 20 mm segments (N = 102) and divided among six groups. Four groups were treated with different pH levels and two served as controls. The specimens were immersed in individual test tubes containing 10 ml of artificial saliva adjusted to a pH of 6.75 or 3.5. The tubes were sealed and stored in a 37 °C water bath for 28 days. After 28 days, the specimens were ligated to brackets embedded in an acrylic block and subjected to mechanical stress using an electronic toothbrush for 210 s. The specimens were photographed, and images were measured for coating loss using AutoCAD® software. Surface morphology was observed using a scanning electron microscope (SEM).

    Results: Significant coating loss (p 

    Matched MeSH terms: Microscopy, Electron, Scanning
  8. Lim MN, Umapathy T, Baharuddin PJ, Zubaidah Z
    Med J Malaysia, 2011 Oct;66(4):335-41.
    PMID: 22299553 MyJurnal
    Transplantation of cultivated limbal epithelium on substrates such as amniotic membrane is an established treatment for severe ocular surface disease with limbal stem cell deficiency. In this study, we adapted an established method to generate sheets of limbal epithelium on amniotic membrane and characterized the cells contained in these sheets and tested them for safety with regard to microbial contamination. Human limbal biopsies were cultivated on denuded amniotic membranes. After three weeks of culture, the phenotypes of cultivated cells were analyzed by immunohistochemistry and real-time RT-PCR for the expression of a panel of specific markers. Cultivated limbal epithelial cell sheets were also analyzed by scanning (SEM) and transmission (TEM) electron microscopy. Sterility tests and mycoplasma assays were conducted for the safety of product. A confluent layer of polygonal cells was formed in 2 weeks and 1-3 stratified layer of cells were observed after three weeks of culture. Cultivated cells were positive for p63, K3, K19, and involucrin but negative for K14, integrin alpha9 and ABCG2 when analyzed by immunohistochemistry. Expression of molecular markers was detectable with real-time RT-PCR. SEM showed multilayer of flat squamous polygonal epithelial cells. Desmosomal and hemidesmosomal attachments were evident. Our study showed that cultivated limbal epithelium consists of limbal progenitors as well as differentiated corneal epithelial cells. SEM and TEM analysis showed cultivated cells demonstrated typical features of corneal epithelium. The risk of contamination is low and can be prevented by culturing the cells in a clean room facility complying to Good Manufacturing Practice standard.
    Matched MeSH terms: Microscopy, Electron, Scanning; Microscopy, Electron, Transmission
  9. Masrudin SS, Ghafar NA, Saidi M, Aminuddin BS, Rahmat A, Ruszymah BH, et al.
    Med J Malaysia, 2008 Jul;63 Suppl A:109-10.
    PMID: 19025009
    The present work was to determine the development and re-epithelization of bilayered corneal construct (BCC) in vitro and in vivo using scanning electron microscopy (SEM). The in vitro BCC was transplanted to the rabbit's eye and after 90 days the BCC was harvested and analyzed. The corneas were processed for morphology studies. The result indicates that the BICC that was transplanted for 90 days showed good development and re-epithelization of epithelial layer similar to the normal cornea.
    Matched MeSH terms: Microscopy, Electron, Scanning*
  10. Au LF, Othman F, Mustaffa R, Vidyadaran S, Rahmat A, Besar I, et al.
    Med J Malaysia, 2008 Jul;63 Suppl A:16-7.
    PMID: 19024962
    Biofilms are adherent, multi-layered colonies of bacteria that are typically more resistant to the host immune response and routine antibiotic therapy. HA biomaterial comprises of a single-phased hydroxyapatite scaffold with interconnected pore structure. The device is designed as osteoconductive space filler to be gently packed into bony voids or gaps following tooth extraction or any surgical procedure. Gentamycin-coated biomaterial (locally made hydroxyapatite) was evaluated to reduce or eradicate the biofilm on the implant materials. The results indicated that the HA coated with gentamycin was biocompatible to human osteoblast cell line and the biofilm has been reduced after being treated with different concentrations of gentamycin-coated hydroxyapatite (HA).
    Matched MeSH terms: Microscopy, Electron, Scanning/instrumentation*; Microscopy, Electron, Scanning/methods
  11. Chua KB, Wong EM, Cropp BC, Hyatt AD
    Med J Malaysia, 2007 Jun;62(2):139-42.
    PMID: 18705447 MyJurnal
    In 1998, a novel paramyxovirus (order Mononegavirales, family Paramyxoviridae, subfamily Paramyxovirinae, genus Henipavirus) emerged in peninsular Malaysia causing fatal encephalitis in humans and severe respiratory illness with encephalitis in pigs. The virus was successfully isolated in cultured mammalian cells. Transmission electron microscopy of infected tissue culture cells played a crucial role in the early preliminary identification of the causative agent of the outbreak. This in turn was pivotal to determine the correct direction of control measures that subsequently brought the epidemic under control. In light of this investigation, and indeed identification of infectious agents associated with other disease episodes, electron microscopy will remain an important frontline method for rapid diagnostic virology and investigation of any future outbreak of new and unusual cases of illness suspected of an infectious aetiology.
    Matched MeSH terms: Microscopy, Electron
  12. Heikal MY, Aminuddin BS, Jeevanan J, Chen HC, Sharifah S, Ruszymah BH
    Med J Malaysia, 2008 Jul;63 Suppl A:34.
    PMID: 19024970
    Normal tracheal mucociliary clearance is the key to maintaining the health and defense of respiratory airway. Therefore the present of cilia and mucous blanket are important for tracheal epithelium to function effectively. In the present study, we prepared a tissue engineered respiratory epithelium construct (TEREC) made of autologous respiratory epithelium cells, fibroblast and fibrin from sheep owns blood which replaced a created tracheal mucosal defect. Scanning electron microscopy (SEM) showed encouraging result where immature cilia were present on the surface of TEREC. This result indicates that engineered respiratory epithelium was able to function as normal tissue.
    Matched MeSH terms: Microscopy, Electron, Scanning*
  13. Zuridah H, Bahaman AR, Mohd Azmi ML, Mutalib AR
    Med J Malaysia, 2004 Jun;59(2):153-9.
    PMID: 15559163 MyJurnal
    A total of 157 stool samples were examined for Group A rotaviruses in diarrheic children admitted to 8 different major hospitals in Malaysia. The overall incidence rate in this study was 19.7% (31 of 157) with a variation of 9.5% to 39.1% in different locations. Majority of the infections detected were in those under 2 years of age and there were fewer admissions in the older age group. The stool samples were initially screened for rotavirus Group A by latex agglutination method and followed by RNA electrophoresis. The size and the characteristics wheel-shaped morphology of the viral preparations when examined by electron-microscopy further confirmed the presence of rotaviruses in the positive stool samples. Analysis of the RNA pattern showed that majority of the isolates, 51.6% (16 of 31) were Type IIC ('long' with comigration of RNA segments 7 and 8), 35.5% (11 of 31) with Type IIG ('long' with comigration of segments 7, 8, 9), 9.7% (3 of 31) with Type IG ('short' with comigration of RNA segments 7, 8, 9) and 3.2% (1 of 31) of mixed or atypical pattern. It appeared that over a 12 year interval, only one new or unusual rotavirus electropherotype was found. This is the first comprehensive report on the electropherotypes of rotaviruses covering eight different geographical locations in Malaysia and the data obtained is useful for understanding the geographic distribution and types of rotaviruses transmitting in Malaysia.
    Matched MeSH terms: Microscopy, Electron
  14. Norazril SA, Aminuddin BS, Norhayati MM, Mazlyzam AL, Fauziah O, Ruszymah BH
    Med J Malaysia, 2004 May;59 Suppl B:186-7.
    PMID: 15468880
    Chitosan has similar structure to glycosaminoglycans in the tissue, thus may be a good candidates as tissue engineering scaffold. However, to improve their cell attachment ability, we try to incorporate this natural polymer with collagen by combining it via cross-linking process. In this preliminary study we evaluate the cell attachment ability of chitosan-collagen scaffold versus chitosan scaffold alone. Chitosan and collagen were dissolved in 1% acetic acid and then were frozen for 24 hours before the lyophilizing process. Human skin fibroblasts were seeded into both scaffold and were cultured in F12: DMEM (1:1). Metabolic activity assay were used to evaluate cell attachment ability of scaffold for a period of 1, 3, 7 and 14 days. Scanning electron micrographs shows good cell morphology on chitosan-collagen hybrid scaffold. In conclusion, the incorporation of collagen to chitosan will enhance its cell attachment ability and will be a potential scaffold in tissue engineering.
    Matched MeSH terms: Microscopy, Electron, Scanning
  15. Phang MY, Ng MH, Tan KK, Aminuddin BS, Ruszymah BH, Fauziah O
    Med J Malaysia, 2004 May;59 Suppl B:198-9.
    PMID: 15468886
    Tricalcium phosphate/hydroxyapatite (TCP/HA), hydroxyapatite (HA), chitosan and calcium sulphate (CaSO4) were studied and evaluated for possible bone tissue engineered construct acting as good support for osteogenic cells to proliferate, differentiate, and eventually spread and integrate into the scaffold. Surface morphology visualized by SEM showed that scaffold materials with additional fibrin had more cell densities attached than those without, depicting that the presence of fibrin and collagen fibers were truly a favourite choice of cells to attach. In comparison of various biomaterials used incorporated with fibrin, TCP/HA had the most cluster of cells attached.
    Matched MeSH terms: Microscopy, Electron, Scanning
  16. Al-Salihi KA
    Med J Malaysia, 2004 May;59 Suppl B:200-1.
    PMID: 15468887
    In the present study, natural coral of porites species was used as scaffold combined with in vitro expanded bone marrow stem cell derived osteoblasts (BMSC-DO), to develop a tissue-engineered bone graft in a rat model. Coral was molded into the shape of rat mandible seeded with 5x10(6) /ml BMSC-DO subsequently implanted subcutaneously in the back of 5 week Sprague dawely rats for 3 months. Coral alone was implanted as a control. The implants were harvest and processed for gross inspection and histological observations. The results showed that newly bone grafts were successfully formed coral seeded with cells group showed smooth highly vascularized like bone tissue. Histological sections revealed mature bone formation and lots of blood vessel, the bone formation occurred in the manner resemble intramembraneous bone formation. This study demonstrates that coral can be use as a suitable scaffold material for delivering bone marrow mesenchymal stem cells in tissue engineering.
    Matched MeSH terms: Microscopy, Electron, Scanning
  17. Norhayati MM, Mazlyzam AL, Asmah R, Fuzina H, Aminuddin BS, Ruszymah BH, et al.
    Med J Malaysia, 2004 May;59 Suppl B:184-5.
    PMID: 15468879
    Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM) evaluation were carried out in the in vivo skin construct using fibrin as biomaterial. To investigate its progressive remodeling, nude mice were grafted and the Extracellular Matrix (ECM) components were studied at four and eight weeks post-grafting. It was discovered that by 4 weeks of remodeling the skin construct acquired its native structure.
    Matched MeSH terms: Microscopy, Electron, Scanning; Microscopy, Electron, Transmission
  18. Rusnah M, Andanastuti M, Idris B
    Med J Malaysia, 2004 May;59 Suppl B:158-9.
    PMID: 15468866
    The present paper reports on the influence of sintering temperature on the porosity and strength of porous hydroxyapatite (HA). HA powder was first prepared by the sol-gel precipitation method using calcium hydroxide and ortho-phosporic acid. The fine HA powder, measuring <50 microm was then mixed into a slurry with the addition of binder agent, being a mixture of sago and PVA. A small amount of sodium dodecyl sulphate was also used as a foaming agent. Porous HA samples were then prepared via slip casting technique. The surface morphology of the sintered samples was observed under scanning electron microscopy at 20 kV and the compositions were determined via SEM-EDX. A universal testing machine was used to determine the compaction strength of the sintered samples.
    Matched MeSH terms: Microscopy, Electron, Scanning
  19. Ang CY, Samsudin AR, Karima AM, Nizam A
    Med J Malaysia, 2004 May;59 Suppl B:149-50.
    PMID: 15468862
    The aim of this study was to evaluate the morphological and biological properties of a locally produced "Bovine Bone Sponge" for use in dentistry. Bovine bone sponge was prepared from local calf bone. Endotoxin level and surface properties were investigated. The pore size and water uptake ability were measured and results were compared with the commercial haemostatic agent. The material was tested for its haemostatic property and its inhibition of alveolar bone resorption in a sheep model following dental extraction. Results revealed a significant difference in haemostatic effect, and a shorter bleeding time and a lower rate of alveolar bone resorption in bovine bone sponge compare to a commercial haemostatic agent.
    Matched MeSH terms: Microscopy, Electron, Scanning
  20. Talib RJ, Toff MR
    Med J Malaysia, 2004 May;59 Suppl B:153-4.
    PMID: 15468864
    Metal implants such as titanium, stainless steel and Co-Cr-Mo are used for load bearing purposes such as hip joint prostheses, fixing plates and dental root implants. For practical application, plasma-sprayed coatings of hydroxyapatite (HA) on metal implants are applied to promote early formation of strong bonds between metal implant and living bone. Plasma spray coating involves heating of HA material to a semi-molten or molten state and then propels its to a metal substrate. The plasma flame temperature is in the range of 6,000 degrees C to 16,000 degrees C but the surface temperature of the substrate rarely exceeds 150 degrees C. The HA materials are feed into the spray gun in the form of powders. Furthermore, this paper will discuss the processes of plasma-sprayed coating of HA on various types of metal implants.
    Matched MeSH terms: Microscopy, Electron, Scanning
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links