METHODS: A randomized trial was performed in a university hospital in Malaysia. Participants were nulliparas at term with unripe cervixes (Bishop Score ≤ 5) admitted for IoL who were randomized to digital or speculum-aided transcervical Foley catheter insertion in lithotomy position. Primary outcomes were insertion duration, pain score [11-point Visual Numerical Rating Scale (VNRS)], and failure. All primary outcomes were recorded after the first insertion.
RESULTS: Data from 86 participants were analysed. Insertion duration (with standard deviation) was 2.72 ± 1.85 vs. 2.25 ± 0.55 min p = 0.12, pain score (VNRS) median [interquartile range] 3.5 [2-5] vs. 3 [2-5] p = 0.72 and failure 2/42 (5%) vs. 0/44 (0%) p = 0.24 for digital vs speculum respectively. There was no significant difference found between the two groups for all three primary outcomes. Induction to delivery 30.7 ± 9.4 vs 29.6 ± 11.5 h p = 0.64, Cesarean section 25/60 (64%) vs 28/64 (60%) RR 0.9 95% CI p = 0.7 and maternal satisfaction VNRS score with the birth process 7 [IQR 6-8] vs 7 [7-8] p = 0.97 for digital vs. speculum arms respectively. Other labor, delivery and neonatal secondary outcomes were not significantly different.
CONCLUSION: Digital and speculum insertion in nulliparas with unripe cervixes had similar insertion performance. As digital insertion required less equipment and consumables, it could be the preferred insertion method for the equally adept and the insertion technique to train towards.
TRIAL REGISTRATION: This trial was registered with ISRCTN registration number 13804902 on 15 November 2017.
Materials & Methods: Total of 45 volunteers aged 18-65 years were included in this study. The degree of overlap in percentage, depth of IJV from skin, antero-posterior (AP) and transverse diameters (TD) of IJV were measured in real time with ultrasound (US). Measurements were taken in the HA, CA and MA in neutral and 30° head rotation on both the right and left side of the neck.
Results: The HA had lower percentage of overlap when compared to CA and MA in neutral and 30° head rotation (p= 0.002 to ≤0.001). The IJV was more shallow in the CA and MA. The AP and TD of the IJV were larger in the MA when compared to HA (p=<0.001) and CA (p =0.026 to < 0.001) and the right IJV has a larger AP and TD in all approaches.
Discussion: The HA had the least percentage of overlap compared to CA and MA, therefore the risk of accidental ICA puncture can be reduced. The apparent overlap seen in MA may not reflect the actual scenario because of the way the US beam cuts the vessel. The AP and TD of IJV were significantly increased in the MA, which would ease CVC.
Conclusion: We conclude and recommend the medial oblique probe position with 30° head rotation provides optimal real time sonographic parameters for US guided IJV cannulation.
MATERIAL AND METHODS: A randomized trial was conducted in the University of Malaya Medical Center. A total of 163 term multiparas (no dropouts) with unripe cervixes (Bishop score ≤5) scheduled for labor induction were randomized to outpatient or inpatient Foley catheter. Primary outcomes were delivery during "working hours" 08:00-18:00 h and maternal satisfaction on allocated care (assessed by 11-point visual numerical rating score 0-10, with higher score indicating more satisfied).
CLINICAL TRIAL REGISTRATION: ISRCTN13534944.
RESULTS: Comparing outpatient and inpatient arms, delivery during working hours were 54/82 (65.9%) vs. 48/81 (59.3%) (relative risk 1.1, 95% CI 0.9-1.4, p = 0.421) and median maternal satisfaction visual numerical rating score was 9 (interquartile range 9-9) vs. 9 (interquartile range 8-9, p = 0.134), repectively. Duration of hospital stay and membrane rupture to delivery interval were significantly shorter in the outpatient arm: 35.8 ± 20.2 vs. 45.2 ± 16.2 h (p = 0.001) and 4.1 ± 2.9 vs. 5.3 ± 3.6 h (p = 0.020), respectively. Other maternal and neonatal secondary outcomes were not significantly different.
CONCLUSIONS: The trial failed to demonstrate the anticipated increase in births during working hours with outpatient compared with inpatient induction of labor with Foley catheter in parous women with an unripe cervix. Hospital stay and membrane rupture to delivery interval were significantly shortened in the outpatient group. The rate of maternal satisfaction was high in both groups and no significant differences were found.