METHODS: A cross-sectional study was conducted among Palestinians > 60 years living in Hebron, West Bank. The Falls Efficacy Scale-International was used to predict falls among Palestinian older adults. Moreover, socio-demographic data, medical history, lifestyle habits, body composition, nutritional status, cognitive status (using the Montreal cognitive assessment tool), and functional status (using activities of daily living and instrumental activities of daily living scale), the presence of depressive symptoms (using geriatric depression scale), and physical fitness performance (using senior fitness test) were collected through an interview-based questionnaire. Data were analyzed using univariate and multivariate approach.
RESULTS: A total of 200 participants were included in the study; 137 (68.5%) females and 63 (31.5%) males. Mean age was 70.5 ± 5.7 years, ranged from 65 to 98 years old. Fear of falling was significantly higher among older adults with advanced aged, living in villages or camps, low educational level, and being married (p < 0.05). Functional status (ADL and IADL), physical fitness status (timed up and go), and depression symptoms were significantly related to fear of falling (p < 0.05).
CONCLUSION: High concern of falling is significantly associated with advanced age, low education level, being married, and living in villages or camps. ADLs were among the factors that had a significant relationship with increased fear of falling. Predictors of fear of falling among Palestinian older adults were IADL scores, body fat percentage, rapid gait speed, timed up and go test. Future studies could investigate further correlates of fear of falling among older adults.
METHODS: Forty-three participants (23 asymptomatic and 20 with CNP) underwent neck proprioception testing, returning to a NHP and THP in both sitting and standing positions (six trials for each test). A laser pointer was secured on the participant's forehead and inertial measurement unit (IMU) sensors were placed beneath the laser pointer and at the level of the spinous process of the seventh cervical vertebra. Both the absolute and the constant JPE were assessed.
FINDINGS: For the asymptomatic participants, good reliability (ICC: 0.79) was found only for right rotation of the THP task in sitting. In standing, good reliability (ICC: 0.77) was only found in flexion for the THP task. In standing, good reliability (ICC: 0.77) was only found for right rotation of the THP for the absolute JPE and left rotation (ICC: 0.85) for the constant error of the NHP task. In those with CNP, when tested in sitting, good reliability was found for flexion (ICC: 0.8) for the absolute JPE and good reliability (ICC range: 0.8-0.84) was found for flexion, extension, and right rotation for the constant JPE. In standing, good reliability (ICC range: 0.81-0.88) was found for flexion, and rotation for the absolute JPE. The constant JPE showed good reliability (ICC: 0.85) for right rotation and excellent reliability (ICC: 0.93) for flexion. Validity was weak to strong (r range: 0.26-0.83) and moderate to very strong (r range: 0.47-0.93) for absolute and constant error respectively, when tested in sitting. In standing, the validity was weak to very strong (0.38-0.96) for the absolute JPE and moderate to very strong (r range: 0.54-0.92) for the constant JPE.
CONCLUSION: The reliability of the measure of JPE when tested in sitting and standing in both groups showed good reliability, but not for all movements. The results of the current study also showed that the laser pointer correlated well with the Noraxon IMUs, but not for all movements. The results of the current study support the use of the JPE using a laser pointer in clinical and research settings.
METHODS: The authors describe a modified second toe transfer that addresses cosmesis in six patients. These include (1) harvesting a flap from the adjacent side of the great toe and insetting it into the volar aspect of the second toe to give more bulk, (2) making skin excisions on each side of the tip to reduce the bulbous appearance, and (3) excising the eponychium to produce apparent lengthening of the nail.
RESULTS: The mean follow-up period was 18 months (range, 6 to 36 months). The procedure resulted in good function and improved cosmesis in all six cases. Part of the great toe flap was lost in one case. The mean two-point discrimination in the transferred toes was 10.1 mm, with protective sensation present in the flaps. The range of motion of the transferred toe was 14 to 38 degrees at the metatarsophalangeal joint, 16 to 55 degrees at the proximal interphalangeal joints, and 20 to 36 degrees in the distal interphalangeal joints. All patients except one were happy with the appearance of the transferred toe.
CONCLUSION: This novel approach will allow patients to take advantage of the lower morbidity to the donor site afforded by second toe-to-thumb transfer and provide the patients with a more aesthetic appearance of the new thumb.
APPROACH: Several master templates are initially generated by applying principal component analysis to data obtained from the PhysioNet MIMIC II database. The master template is then updated with each incoming clean PPG pulse. The correlation coefficient is used to classify the PPG pulse into either good or bad quality categories. The performance of our algorithm was evaluated using data obtained from two different sources: (i) our own data collected from 19 healthy subjects using the wearable Sotera Visi Mobile system (Sotera Wireless Inc.) as they performed various movement types; and (ii) ICU data provided by the PhysioNet MIMIC II database. The developed algorithm was evaluated against a manually annotated 'gold standard' (GS).
MAIN RESULTS: Our algorithm achieved an overall accuracy of 91.5% ± 2.9%, with a sensitivity of 94.1% ± 2.7% and a specificity of 89.7% ± 5.1%, when tested on our own data. When applying the algorithm to data from the PhysioNet MIMIC II database, it achieved an accuracy of 98.0%, with a sensitivity and specificity of 99.0% and 96.1%, respectively.
SIGNIFICANCE: The proposed method is simple and robust against individual variations in the PPG characteristics, thus making it suitable for a diverse range of datasets. Integration of the proposed artefact detection technique into remote monitoring devices could enhance reliability of the PPG-derived physiological parameters.