Displaying publications 101 - 113 of 113 in total

Abstract:
Sort:
  1. Gupta R, Elamvazuthi I, Dass SC, Faye I, Vasant P, George J, et al.
    Biomed Eng Online, 2014;13:157.
    PMID: 25471386 DOI: 10.1186/1475-925X-13-157
    Disorders of rotator cuff tendons results in acute pain limiting the normal range of motion for shoulder. Of all the tendons in rotator cuff, supraspinatus (SSP) tendon is affected first of any pathological changes. Diagnosis of SSP tendon using ultrasound is considered to be operator dependent with its accuracy being related to operator's level of experience.
    Matched MeSH terms: Image Processing, Computer-Assisted/methods*
  2. Othman SA, Ahmad R, Mericant AF, Jamaludin M
    Aust Orthod J, 2013 May;29(1):58-65.
    PMID: 23785939
    Fast and non-invasive systems of the three-dimensional (3D) technology are a recent trend in orthodontics. The reproducibility of facial landmarks is important so that 3D facial measurements are accurate and may-be applied clinically. The aim of this study is to evaluate the reproducibility of facial soft tissue landmarks using a non-invasive stereo-photogrammetry 3D camera.
    Matched MeSH terms: Image Processing, Computer-Assisted/methods*
  3. Isa ZM, Abdulhadi LM
    J Oral Sci, 2012;54(2):159-63.
    PMID: 22790408
    We investigated the relationship of the maxillary central incisors to the incisive papilla in wearers of complete dentures. First, image analyzer software was used to examine the relationship of the midpoint of the incisive papilla to the labial surface of the maxillary central incisors on occlusal photographs of 120 maxillary casts from dentate Malaysian adults. Then, an Alma denture gauge was used to identify the position of the labial surface of the maxillary central incisors in relation to the midpoint of the incisive papilla in complete dentures from 51 patients who requested replacement dentures at the Faculty of Dentistry, University of Malaya. The mean incisor distance to the incisive papilla in dentate adults was 9.59 ± 1.00 mm, while the mean incisor distance to the incisive papilla in complete dentures was 6.34 ± 1.87 mm. Thus, in our sample of edentulous patients, the anterior teeth in complete dentures were positioned approximately 3 mm closer to the incisive papilla, as compared with the position of the central incisors in natural dentition, and did not duplicate the position of the natural anterior teeth.
    Matched MeSH terms: Image Processing, Computer-Assisted/methods
  4. Al-Khatib AR, Rajion ZA, Masudi SM, Hassan R, Anderson PJ, Townsend GC
    Orthod Craniofac Res, 2011 Nov;14(4):243-53.
    PMID: 22008304 DOI: 10.1111/j.1601-6343.2011.01529.x
    To investigate tooth size and dental arch dimensions in Malays using a stereophotogrammetric system.
    Matched MeSH terms: Image Processing, Computer-Assisted/methods
  5. Banabilh SM, Suzina AH, Mohamad H, Dinsuhaimi S, Samsudin AR, Singh GD
    Clin Oral Investig, 2010 Oct;14(5):491-8.
    PMID: 19806371 DOI: 10.1007/s00784-009-0342-9
    The aim of the present study is to investigate nasal airway morphology in Asian adults with and without obstructive sleep apnea (OSA) using acoustic rhinometry (AR), principal components analysis (PCA), and 3-D finite-element analysis (FEA). One hundred eight adult Malays aged 18-65 years (mean ± SD, 33.2 ± 13.31) underwent clinical examination and limited channel polysomnography, providing 54 patients with OSA and 54 non-OSA controls. The mean minimal cross section area 1 (MCA1) and the mean minimal cross sectional area 2 (MCA2) were obtained from AR for all subjects and subjected to t tests. The OSA and control nasal airways were reconstructed in 3-D and subjected to PCA and FEA. The mean MCA1 and MCA2 using AR were found to be significantly smaller in the OSA group than in the control group (p < 0.001). Comparing the 3-D OSA and control nasal airways using PCA, the first two eigenvalues accounted for 94% of the total shape change, and statistical differences were found (p < 0.05). Similarly, comparing the nasal airways using FEA, the 3-D mean OSA nasal airway was significantly narrower in the OSA group compared to the control group. Specifically, decreases in size of approx. 10-22% were found in the nasal valve/head of inferior turbinate area. In conclusion, differences in nasal airway morphology are present when comparing patients with OSA to controls. These differences need to be recognized as they can improve our understanding of the etiological basis of obstructive sleep apnea and facilitate its subsequent management.
    Matched MeSH terms: Image Processing, Computer-Assisted/methods
  6. Abdullah A, Mahmud MR, Maimunah A, Zulfiqar MA, Saim L, Mazlan R
    Ann Acad Med Singap, 2003 Jul;32(4):442-5.
    PMID: 12968546
    INTRODUCTION: Accurate preoperative imaging of the temporal bone in patients receiving cochlear implants is important. High resolution computed tomography (HRCT) and magnetic resonance (MR) imaging are the 2 preoperative imaging modalities that provide critical information on abnormalities of the otic capsule, pneumatisation of the mastoid, middle ear abnormalities, cochlear ducts patency and presence of cochlear nerve.

    MATERIALS AND METHODS: The HRCT and MR imaging in 46 cochlear implant patients in our department were reviewed.

    RESULTS: Majority of our patients [34 patients (73.9%)] showed normal HRCT of the temporal bone; 5 (10.9%) patients had labyrinthitis ossificans, 2 (4.3%) had Mondini's abnormality and 2 (4.3%) had middle ear effusion. One patient each had high jugular bulb, hypoplasia of the internal auditory canal and single cochlear cavity, respectively.

    CONCLUSION: The above findings contribute significantly to our surgical decisions regarding candidacy for surgery, side selection and surgical technique in cochlear implantation.

    Matched MeSH terms: Image Processing, Computer-Assisted/methods*
  7. Siotia J, Gupta SK, Acharya SR, Saraswathi V
    Int J Comput Dent, 2011;14(4):321-34.
    PMID: 22324223
    Radiographic examination is essential in diagnosis and treatment planning in endodontics. Conventional radiographs depict structures in two dimensions only. The ability to assess the area of interest in three dimensions is advantageous. Computed tomography is an imaging technique which produces three-dimensional images of an object by taking a series of two-dimensional sectional X-ray images. DentaScan is a computed tomography software program that allows the mandible and maxilla to be imaged in three planes: axial, panoramic, and cross-sectional. As computed tomography is used in endodontics, DentaScan can play a wider role in endodontic diagnosis. It provides valuable information in the assessment of the morphology of the root canal, diagnosis of root fractures, internal and external resorptions, pre-operative assessment of anatomic structures etc. The aim of this article is to explore the clinical usefulness of computed tomography and DentaScan in endodontic diagnosis, through a series of four cases of different endodontic problems.
    Matched MeSH terms: Image Processing, Computer-Assisted/methods
  8. Said MA, Musarudin M, Zulkaffli NF
    Ann Nucl Med, 2020 Dec;34(12):884-891.
    PMID: 33141408 DOI: 10.1007/s12149-020-01543-x
    OBJECTIVE: 18F is the most extensively used radioisotope in current clinical practices of PET imaging. This selection is based on the several criteria of pure PET radioisotopes with an optimum half-life, and low positron energy that contributes to a smaller positron range. In addition to 18F, other radioisotopes such as 68Ga and 124I are currently gained much attention with the increase in interest in new PET tracers entering the clinical trials. This study aims to determine the minimal scan time per bed position (Tmin) for the 124I and 68Ga based on the quantitative differences in PET imaging of 68Ga and 124I relative to 18F.

    METHODS: The European Association of Nuclear Medicine (EANM) procedure guidelines version 2.0 for FDG-PET tumor imaging has adhered for this purpose. A NEMA2012/IEC2008 phantom was filled with tumor to background ratio of 10:1 with the activity concentration of 30 kBq/ml ± 10 and 3 kBq/ml ± 10% for each radioisotope. The phantom was scanned using different acquisition times per bed position (1, 5, 7, 10 and 15 min) to determine the Tmin. The definition of Tmin was performed using an image coefficient of variations (COV) of 15%.

    RESULTS: Tmin obtained for 18F, 68Ga and 124I were 3.08, 3.24 and 32.93 min, respectively. Quantitative analyses among 18F, 68Ga and 124I images were performed. Signal-to-noise ratio (SNR), contrast recovery coefficients (CRC), and visibility (VH) are the image quality parameters analysed in this study. Generally, 68Ga and 18F gave better image quality as compared to 124I for all the parameters studied.

    CONCLUSION: We have defined Tmin for 18F, 68Ga and 124I SPECT CT imaging based on NEMA2012/IEC2008 phantom imaging. Despite the long scanning time suggested by Tmin, improvement in the image quality is acquired especially for 124I. In clinical practice, the long acquisition time, nevertheless, may cause patient discomfort and motion artifact.

    Matched MeSH terms: Image Processing, Computer-Assisted/methods
  9. Ninomiya K, Arimura H, Chan WY, Tanaka K, Mizuno S, Muhammad Gowdh NF, et al.
    PLoS One, 2021;16(1):e0244354.
    PMID: 33428651 DOI: 10.1371/journal.pone.0244354
    OBJECTIVES: To propose a novel robust radiogenomics approach to the identification of epidermal growth factor receptor (EGFR) mutations among patients with non-small cell lung cancer (NSCLC) using Betti numbers (BNs).

    MATERIALS AND METHODS: Contrast enhanced computed tomography (CT) images of 194 multi-racial NSCLC patients (79 EGFR mutants and 115 wildtypes) were collected from three different countries using 5 manufacturers' scanners with a variety of scanning parameters. Ninety-nine cases obtained from the University of Malaya Medical Centre (UMMC) in Malaysia were used for training and validation procedures. Forty-one cases collected from the Kyushu University Hospital (KUH) in Japan and fifty-four cases obtained from The Cancer Imaging Archive (TCIA) in America were used for a test procedure. Radiomic features were obtained from BN maps, which represent topologically invariant heterogeneous characteristics of lung cancer on CT images, by applying histogram- and texture-based feature computations. A BN-based signature was determined using support vector machine (SVM) models with the best combination of features that maximized a robustness index (RI) which defined a higher total area under receiver operating characteristics curves (AUCs) and lower difference of AUCs between the training and the validation. The SVM model was built using the signature and optimized in a five-fold cross validation. The BN-based model was compared to conventional original image (OI)- and wavelet-decomposition (WD)-based models with respect to the RI between the validation and the test.

    RESULTS: The BN-based model showed a higher RI of 1.51 compared with the models based on the OI (RI: 1.33) and the WD (RI: 1.29).

    CONCLUSION: The proposed model showed higher robustness than the conventional models in the identification of EGFR mutations among NSCLC patients. The results suggested the robustness of the BN-based approach against variations in image scanner/scanning parameters.

    Matched MeSH terms: Image Processing, Computer-Assisted/methods*
  10. Chew HP, Zakian CM, Pretty IA, Ellwood RP
    Caries Res, 2014;48(3):254-62.
    PMID: 24481141 DOI: 10.1159/000354411
    BACKGROUND: Measurement of initial enamel erosion is currently limited to in vitro methods. Optical coherence tomography (OCT) and quantitative light-induced fluorescence (QLF) have been used clinically to study advanced erosion. Little is known about their potential on initial enamel erosion.

    OBJECTIVES: To evaluate the sensitivity of QLF and OCT in detecting initial dental erosion in vitro.

    METHODS: 12 human incisors were embedded in resin except for a window on the buccal surface. Bonding agent was applied to half of the window, creating an exposed and non-exposed area. Baseline measurements were taken with QLF, OCT and surface microhardness. Samples were immersed in orange juice for 60 min and measurements taken stepwise every 10 min. QLF was used to compare the loss of fluorescence between the two areas. The OCT system, OCS1300SS (Thorlabs Ltd.), was used to record the intensity of backscattered light of both areas. Multiple linear regression and paired t test were used to compare the change of the outcome measures.

    RESULTS: All 3 instruments demonstrated significant dose responses with the erosive challenge interval (p < 0.05) and a detection threshold of 10 min from baseline. Thereafter, surface microhardness demonstrated significant changes after every 10 min of erosion, QLF at 4 erosive intervals (20, 40, 50 and 60 min) while OCT at only 2 (50 and 60 min).

    CONCLUSION: It can be concluded that OCT and QLF were able to detect demineralization after 10 min of erosive challenge and could be used to monitor the progression of demineralization of initial enamel erosion in vitro.

    Matched MeSH terms: Image Processing, Computer-Assisted/methods
  11. Abas FS, Shana'ah A, Christian B, Hasserjian R, Louissaint A, Pennell M, et al.
    Cytometry A, 2017 06;91(6):609-621.
    PMID: 28110507 DOI: 10.1002/cyto.a.23049
    The advance of high resolution digital scans of pathology slides allowed development of computer based image analysis algorithms that may help pathologists in IHC stains quantification. While very promising, these methods require further refinement before they are implemented in routine clinical setting. Particularly critical is to evaluate algorithm performance in a setting similar to current clinical practice. In this article, we present a pilot study that evaluates the use of a computerized cell quantification method in the clinical estimation of CD3 positive (CD3+) T cells in follicular lymphoma (FL). Our goal is to demonstrate the degree to which computerized quantification is comparable to the practice of estimation by a panel of expert pathologists. The computerized quantification method uses entropy based histogram thresholding to separate brown (CD3+) and blue (CD3-) regions after a color space transformation. A panel of four board-certified hematopathologists evaluated a database of 20 FL images using two different reading methods: visual estimation and manual marking of each CD3+ cell in the images. These image data and the readings provided a reference standard and the range of variability among readers. Sensitivity and specificity measures of the computer's segmentation of CD3+ and CD- T cell are recorded. For all four pathologists, mean sensitivity and specificity measures are 90.97 and 88.38%, respectively. The computerized quantification method agrees more with the manual cell marking as compared to the visual estimations. Statistical comparison between the computerized quantification method and the pathologist readings demonstrated good agreement with correlation coefficient values of 0.81 and 0.96 in terms of Lin's concordance correlation and Spearman's correlation coefficient, respectively. These values are higher than most of those calculated among the pathologists. In the future, the computerized quantification method may be used to investigate the relationship between the overall architectural pattern (i.e., interfollicular vs. follicular) and outcome measures (e.g., overall survival, and time to treatment). © 2017 International Society for Advancement of Cytometry.
    Matched MeSH terms: Image Processing, Computer-Assisted/methods
  12. Tang JR, Mat Isa NA, Ch'ng ES
    PLoS One, 2015;10(11):e0142830.
    PMID: 26560331 DOI: 10.1371/journal.pone.0142830
    Despite the effectiveness of Pap-smear test in reducing the mortality rate due to cervical cancer, the criteria of the reporting standard of the Pap-smear test are mostly qualitative in nature. This study addresses the issue on how to define the criteria in a more quantitative and definite term. A negative Pap-smear test result, i.e. negative for intraepithelial lesion or malignancy (NILM), is qualitatively defined to have evenly distributed, finely granular chromatin in the nuclei of cervical squamous cells. To quantify this chromatin pattern, this study employed Fuzzy C-Means clustering as the segmentation technique, enabling different degrees of chromatin segmentation to be performed on sample images of non-neoplastic squamous cells. From the simulation results, a model representing the chromatin distribution of non-neoplastic cervical squamous cell is constructed with the following quantitative characteristics: at the best representative sensitivity level 4 based on statistical analysis and human experts' feedbacks, a nucleus of non-neoplastic squamous cell has an average of 67 chromatins with a total area of 10.827 μm2; the average distance between the nearest chromatin pair is 0.508 μm and the average eccentricity of the chromatin is 0.47.
    Matched MeSH terms: Image Processing, Computer-Assisted/methods
  13. Zreaqat M, Hassan R, Halim AS
    Int J Oral Maxillofac Surg, 2012 Jun;41(6):783-8.
    PMID: 22424709 DOI: 10.1016/j.ijom.2012.02.003
    This comparative cross-sectional study assessed the facial surface dimensions of a group of Malay children with unilateral cleft lip and palate (UCLP) and compared them with a control group. 30 Malay children with UCLP aged 8-10 years and 30 unaffected age-matched children were voluntarily recruited from the Orthodontic Specialist Clinic in Hospital Universiti Sains Malaysia (HUSM). For the cleft group, lip and palate were repaired and assessment was performed prior to alveolar bone grafting and orthodontic treatment. The investigation was carried out using 3D digital stereophotogrammetry. 23 variables and two ratios were compared three-dimensionally between both groups. Statistically significant dimensional differences (P<0.05) were found between the UCLP Malay group and the control group mainly in the nasolabial region. These include increased alar base and alar base root width, shorter upper lip length, and increased nose base/mouth width ratio in the UCLP group. There were significant differences between the facial surface morphology of UCLP Malay children and control subjects. Particular surgical procedures performed during primary surgeries may contribute to these differences and negatively affect the surgical outcome.
    Matched MeSH terms: Image Processing, Computer-Assisted/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links