METHODS: Participants were 997 university undergraduate students, with a mean age of 21 years (SD = 1.58). The majority of the participants (80.4%) were female. Health-promoting behaviour was assessed using the 52-item HPLP-II, which measures six components of health-promoting behaviour outcomes. HPLP-II was translated into the Malay language using standard forward and backward translation procedures. Participants then completed the HPLP-II Malay version (HPLP-II-M). Confirmatory factor analysis (CFA) was conducted using Mplus 8.0 software on the six domains of HPLP-II-M model.
RESULTS: The CFA result based on the hypothesised measurement model of six factors was aligned with the original HPLP-II, except for two low loading items which were subsequently removed from the CFA analysis. The final CFA measurement model with 50 items resulted in a good fit to the data based on RMSEA and SRMR fit indices (RMSEA = 0.046, 90%CI = 0.045, 0.048, SRMR = 0.062). The construct reliabilities for the HPLP-II-M subscales were acceptable, ranging from 0.737 to 0.878.
CONCLUSION: The HPLP-II-M with six components of health-promoting behaviour outcomes and 50 items was considered valid and reliable for the present Malaysian sample.
METHOD: This systematic review was conducted to identify and describe FFQs that measure dietary intake of pre-diabetic patients and to examine their relative validity and reliability. The systematic search was done through electronic databases such as PubMed, CINAHL, PsycINFO, ProQuest and Scopus. Methodological quality of included studies and results of study outcome was also summarized in this review.
RESULT: The search identified 445 papers, of which 18 studies reported 15 FFQs, met inclusion criteria. Most of the FFQs (n = 12) were semi-quantitative while three were frequency measures with portion size estimation of selected food items. Test-retest reliability of FFQ was reported in 7 (38.3%) studies with the correlation coefficient of 0.33-0.92. Relative validity of FFQ was reported in 16 (88.8%) studies with the range of correlation coefficient of 0.08-0.83. Dietary patterns rich in carbohydrate, fat, animal protein and n-3 fatty acids were associated with increased risk of pre-diabetes.
CONCLUSION: No well-established disease-specific FFQ identified in the literature. Development of a valid, practical and reliable tool is needed for better understanding of the impact of diet in pre-diabetic population.
METHODS: A novel research instrument known as the rheumatoid arthritis knowledge assessment scale (RAKAS) which consisted of 13 items, was formulated by a rheumatology panel and used for this study. This study was conducted in rheumatology clinics of three tertiary care hospitals in Karachi, Pakistan. The study was conducted in March-April 2018. Patients were recruited using a randomized computer-generated list of appointments. Sample size was calculated based on item-to-respondent ratio of 1:15. The validities, factor structure, sensitivity, reliability and internal consistency of RAKAS were assessed. The study was approved by the institutional Ethics Committee.
RESULTS: A total of 263 patients responded to the study. Content validity was 0.93 and response rate was 89.6%. Factor analysis revealed a 3-factor structure. Fit indices, namely normed fit index (NFI), Tucker Lewis index (TLI), comparative fit index (CFI) and root mean square of error approximation (RMSEA) were calculated with satisfactory results, that is, NFI, TLI and CFI > 0.9, and RMSEA 19 and difficulty index <0.95. Sensitivity and specificity of RAKAS were above 90%. The tool established construct and known group validities.
CONCLUSION: A novel tool to document disease knowledge in patients with RA was formulated and validated.
METHODS: The scale was translated following the standard procedures. For psychometric validation, the Turkish version of the PATE scale was administered to 201 native Turkish speakers above the age of 18 who had no history of seizures or epilepsy. It was found that the respondents were able to fill out the scale quickly and without difficulty in understanding the translated items on the scale.
RESULTS: Cronbach's alpha coefficient was found to be 0.843 for the overall scale and above 0.7 for each individual item. Cronbach's alpha was 0.78 for the general domain and 0.792 for the personal domain. Exploratory and confirmatory factor analyses were carried out and showed that the scale had a structure similar to that of the original scale, with the 14 items grouped under two dimensions, similar to the original scale.
CONCLUSION: The Turkish version of the PATE scale was a valid and reliable tool to measure the attitudes toward epilepsy in Turkish society.
METHODS: Healthcare workers (HCWs) from major healthcare facilities participated in this cross-sectional study. A self-administered questionnaire comprising of five main domains (demographics, knowledge, self-preparedness, counselling practice, perceived barriers) was distributed among HCWs after obtaining informed consent. A convenient sampling technique was used. Descriptive and inferential analyses were applied using SPSS software.
RESULTS: A total of 1000 participants were initially targeted to participate in the study with 514 (51.4%) responding, of which 55.3% were female. Physicians and nurses constituted the largest proportion of participants, with 39.5% and 33.3%, respectively. The median scores for knowledge, self-preparedness, and counselling practice were 8 (out of 9), 9 (out of 15), and 25 (out of 30), respectively. The physician group showed a statistically significant association with better knowledge compared to the nurse group only, P<0.001. Males had higher preparedness scores than females, p<0.001. Also, the intensive care unit (ICU) and emergency departments presented a statistically significant difference by which the participants from these departments were more prepared compared to the others (e.g. outpatients, paediatrics and surgery) with P < 0.0001. The lack of awareness among the general population about COVID-19 preventive measures was perceived as the most common barrier for the adequate prevention and control of COVID-19 in Yemen (89.1%).
CONCLUSION: The major highlight of this study is that HCWs have, overall, good knowledge, suboptimal preparedness, and adequate counselling practices prior to the outbreak of COVID-19 in Yemen, despite the high number of perceived barriers. However, urgent action and interventions are needed to improve the preparedness of HCWs to manage COVID-19. The perceived barriers also need to be fully addressed by the local healthcare authorities and international organisations working in Yemen for adequate prevention and control measures to be in place in managing COVID-19.
METHOD: Here we present a new case history instrument which is comprehensive in scope and can be answered by people with and without tinnitus alike. This 'European School for Interdisciplinary Tinnitus Research Screening Questionnaire' (ESIT-SQ) was developed with specific attention to questions about potential risk factors for tinnitus (including demographics, lifestyle, general medical and otological histories), and tinnitus characteristics (including perceptual characteristics, modulating factors, and associations with co-existing conditions). It was first developed in English, then translated into Dutch, German, Italian, Polish, Spanish, and Swedish, thus having broad applicability and supporting international collaboration.
CONCLUSIONS: With respect to better understanding tinnitus profiles, we anticipate the ESIT-SQ to be a starting point for comprehensive multi-variate analyses of tinnitus. Data collected with the ESIT-SQ can allow establishment of patterns that distinguish tinnitus from non-tinnitus, and definition of common sets of tinnitus characteristics which might be indicated by the presence of otological or comorbid systemic diseases for which tinnitus is a known symptom.
DESIGN/METHODOLOGY/APPROACH: This cross-sectional study comprised 252 patients visiting HUSM. Patients were selected using the convenience sampling method. The PGQ (Bahasa Melayu version) had three main factors: during your visit; your care provider and overall assessment. Data were analyzed using the structural equation modeling.
FINDINGS: The exploratory factor analysis resulted in item reduction from 21 to 17, which contained four factors with eigenvalues greater than 1. Meanwhile, confirmatory factor analysis results showed that data fitted the model: χ2/df at 1.764, comparative fit index at 0.952, Tucker-Lewis index at 0.941 and root mean square error of approximation at 0.073. The average variance extracted value for the four factors was greater than 0.50, which indicated that PGQ convergent validity was met. Overall, PGQ produced good reliability with composite reliability score equals to 0.966. Four factors were reclassified as "during your registration," "hospital staff attitude," "doctor's attitude" and "overall assessment."
RESEARCH LIMITATIONS/IMPLICATIONS: Patient satisfaction is an important and frequently used indicator for measuring healthcare quality; hence, a validated and reliable instrument is important for measuring patient satisfaction that leads to healthcare service quality assessment.
PRACTICAL IMPLICATIONS: Validated PGQ provides some useful information for doctors, medical assistants, nurses and staff in the emergency department to help them become more prominent and efficient in their role as healthcare providers.
SOCIAL IMPLICATIONS: Validated PGQ will help healthcare providers to deliver the best and exceptional care toward emergency patient, and thus improve their quality of work life. The findings in this study can be used as a guide or as baseline data for further research in this area.
ORIGINALITY/VALUE: The PQG (Bahasa Melayu version) was confirmed as a reliable and valid instrument for measuring patient satisfaction. This research is the first PGQ validation study in Southeast Asia, specifically focusing on Malaysian respondents.
METHODS: A cross-sectional survey using the EQ-5D-3L instrument was conducted between May to September 2018 across various public hospitals in Malaysia. Using a multi-stage sampling, patients diagnosed with TDT and receiving iron chelating therapy were sampled. The findings on the EQ-5D-3L survey were converted into utility values using local tariff values. A two-part model was used to examine and derive the HSUVs associated with the treatment and complications of iron overload in TDT.
RESULTS: A total of 585 patients were surveyed. The unadjusted mean (SD) EQ-5D-3L utility value for TDT patients were 0.893 (0.167) while mean (SD) EQ VAS score was 81.22 (16.92). Patients who had more than two iron overload complications had a significant decline in HRQoL. Patients who were on oral monotherapy had a higher utility value of 0.9180 compared to other regimen combinations.
CONCLUSION: Lower EQ-5D-3L utility values were associated with patients who developed iron overload complications and were on multiple iron chelating agents. Emphasizing compliance to iron chelating therapy to prevent the development of complications is crucial in the effort to preserve the HRQoL of TDT patients.
METHODS: The standard forward-backwards translation technique was used to convert English version of the WHOQOL HIV Bref into Urdu. After cognitive debriefing, final Urdu version of instrument was developed. Based on the principle of at least 5 subjects for each item, a sample of 182 patients was used using a universal random sampling technique from the Pakistan Institute of Medical Sciences, Islamabad. The Cronbach's alpha and intra-class correlation coefficients (ICC) were estimated to assess internal validity and reliability of the translated version. Exploratory factor analysis was carried out to determine the factor structure and independent associations between the instrument domains and CD-4T-cell count were assessed using multivariable linear regression RESULTS: High Cronbach alpha 0.93 was found for all WHOQOL HIV Bref facets. The test-retest reliability demonstrated a statistically significant ICC ranged from 0.88 to 0.98 (p
METHODS: A cross-sectional study was conducted. The translated Malay version of the WOMBLSQ was completed by 200 postpartum women in a tertiary hospital. The Rasch model was applied to investigate the statistics, unidimensionality, item polarity and misfit, person misfit and person item distribution map.
RESULTS: The Rasch analysis showed that the 27 items, in nine dimensions, had high item reliability and item separation at 0.98 and 7.65 respectively, while good person reliability and person separation were at 0.78 and 1.90, respectively. Item 6 ('My birth partner/husband couldn't have supported me any better') (outfit MnSq = 1.74, outfit z-std = 6.9, PtMea Corr = - 0.02) and Item 5 ('My birth partner/husband helped me to understand what was going on when I was in labor') (outfit MnSq = 1.65, outfit z-std = 2.9, PtMea Corr = 0.13) are misfit. Item 6 needs to be re-examined for removal or rephrasing, while Item 5 correlates poorly with the construct. Eight persons have the most misfitting response strings based on Item 6 but extremely trivial differences were found in the parameter estimates after refitting the model. Ten items easily endorse satisfaction from the respondents.
CONCLUSION: The WOMBLSQ tested among postpartum women has been shown to have a good person reliability index and a high item reliability index. Items 5 and 6 do not contribute in the construction of scale but not degrading and suggested for refining. The spread of item difficulty should be improved in the future modification of items.