Displaying all 4 publications

Abstract:
Sort:
  1. Sulieman A, Taha A, Dawood S, Almujally A, Bradley DA
    Appl Radiat Isot, 2024 Oct;212:111440.
    PMID: 39018816 DOI: 10.1016/j.apradiso.2024.111440
    The sensitivity to ionizing radiation is increasing by age of development for some malignant tumors. Therefore, children have higher risk to radiation induced tumors due the high cellular rate of proliferation and long lifespan probability. The risk is also increase with increase the effective and organ doses. Computed tomography (CT) exposed pediatric patients to higher radiation dose during multiphase image acquisition, repeated exams, for follow-up procedures. This research intended to estimate the radiogenic risks and effective radiation doses resulted from CT enhanced contrast for abdomen and pelvis. 126 (66 (62.3%) males, 60 (47.7%) females) pediatric patients underwent CT enhanced abdominal examination at Medical Imaging Department at King Khalid Hospital and Prince Sultan Center for Health Services, Alkharj, Saudi Arabia. The average and range of pediatric age (years) is 11.6 ± 5.0 (0.1-17). The mean, standard deviation, and range of the volume CT air kerma index (CVOL (mGy) and the air kerma length product (PKL, mGy.cm) were 9.8 ± 9.4 (2.1-45.8) and 1795 (221-3150) per abdominopelvic procedure, respectively. The mean and range of the effective dose (mSv) per procedure are 26.9 (2.4-59.1). The effective dose is higher compared to the most previously published studies. The effective dose per pediatric abdomen and pelvis with contrast procedure suggest that the patient dose is not optimized yet. Because the chest and pelvis region contain sensitive organs that are irradiated repeatedly, dose optimization is crucial.
  2. Bushra A, Sulieman A, Edam A, Tamam N, Babikir E, Alrihaima N, et al.
    Appl Radiat Isot, 2023 Mar;193:110627.
    PMID: 36584412 DOI: 10.1016/j.apradiso.2022.110627
    Computed tomography is widely used for planar imaging. Previous studies showed that CR systems involve higher patient radiation doses compared to digital systems. Therefore, assessing the patient's dose and CR system performance is necessary to ensure that patients received minimal dose with the highest possible image quality. The study was performed at three medical diagnostic centers in Sudan: Medical Corps Hospital (MCH), Advance Diagnostic Center (ADC), and Advance Medical Center (AMC). The following tools were used in this study: Tape measure, Adhesive tape, 1.5 mm copper filtration (>10 × 10 cm), TO 20 threshold contrast test object, Resolution test object (e.g., Huttner 18), MI geometry test object or lead ruler, Contact mish, Piranha (semiconductor detector), Small lead or copper block (∼5 × 5 cm), and Steel ruler, to do a different type of tests (Dark Noise, Erasure cycle efficiency, Sensitivity Index calibration, Sensitivity Index consistency, Uniformity, Scaling errors, Blurring, Limiting spatial Resolution, Threshold, and Laser beam Function. Entrance surface air kerma (ESAK (mGy) was calculated from patient exposure parameters using DosCal software for three imaging modalities. A total of 199 patients were examined (112 chest X rays, 77 lumbar spine). The mean and standard deviation (sd) for patients ESAK (mGy) were 2.56 ± 0.1 mGy and 1.6 mGy for the Anteroposterior (AP) and lateral projections for the lumbar spine, respectively. The mean and sd for the patient's chest doses were 0.1 ± 0.01 for the chest X-ray procedures. The three medical diagnostic centers' CR system performance was evaluated and found that all of the three centers have good CR system functions. All the centers satisfy all the criteria of acceptable visual tests. CR's image quality and sensitivity were evaluated, and the CR image is good because it has good contrast and resolution. All the CR system available in the medical centers and upgraded from old X-ray systems to new systems, has been found to work well. The patient's doses were comparable for the chest X-ray procedures, while patients' doses from the lumbar spine showed variation up to 2 folds due to the variation in patients' weight and X-ray machine setting. Patients dose optimization is recommended to ensure the patients received a minimal dose while obtaining the diagnostic findings.
  3. Bose R, Jayawant M, Raut R, Lakkakula J, Roy A, Alghamdi S, et al.
    Front Pharmacol, 2023;14:1218867.
    PMID: 37601050 DOI: 10.3389/fphar.2023.1218867
    The field of cancer nanotheranostics is rapidly evolving, with cyclodextrin (CD)-based nanoparticles emerging as a promising tool. CDs, serving as nanocarriers, have higher adaptability and demonstrate immense potential in delivering powerful anti-cancer drugs, leading to promising and specific therapeutic outcomes for combating various types of cancer. The unique characteristics of CDs, combined with innovative nanocomplex creation techniques such as encapsulation, enable the development of potential theranostic treatments. The review here focuses mainly on the different techniques administered for effective nanotheranostics applications of CD-associated complex compounds in the domain of cancer treatments. The experimentations on various loaded drugs and their complex conjugates with CDs prove effective in in vivo results. Various cancers can have potential nanotheranostics cures using CDs as nanoparticles along with a highly efficient process of nanocomplex development and a drug delivery system. In conclusion, nanotheranostics holds immense potential for targeted drug delivery and improved therapeutic outcomes, offering a promising avenue for revolutionizing cancer treatments through continuous research and innovative approaches.
  4. Isinkaye MO, OlaOlorun OA, Chandrasekaran A, Adekeye AS, Dada TE, Tamilarasi A, et al.
    Heliyon, 2023 Nov;9(11):e22451.
    PMID: 38034673 DOI: 10.1016/j.heliyon.2023.e22451
    Assessment of activity levels of radionuclides that exist in soil, granite, and charnockite rock samples is very crucial because it exhibits an enhanced elemental concentration of uranium (U) and thorium (Th) contributing higher natural background activity than usual in the environment and it may cause health risk to human health through the external and internal exposure. This study determined the radioactivity levels of 238U, 232Th, and 40K radionuclides in soil, granite, and charnockite rock samples collected from selected fields in Ekiti State, Nigeria using Caesium iodide CsI(Tl) scintillation gamma spectrometer. It also evaluated indices of the radiological parameters consisting of radium equivalent activity (Raeq), absorbed dose rate (DR), annual effective dose equivalent (AEDE), internal hazard index (Hin), and excess lifetime cancer risk (ELCR). The calculated average activity concentrations of 238U, 232Th, and 40K are 30.40 ± 0.71 Bq kg-1, 3.31 ± 0.05 Bq kg-1, and 222.25 ± 14.72 Bq kg-1, respectively, which were lower than their respective world average values. Comparatively, potassium concentrations in these collected samples have a higher value than concentrations of uranium and thorium (40K > 238U > 232Th). All the evaluated values of the radiological parameters (except DR) of the appraised radionuclides were below the global permissible limits. The granite rocks, charnockite rocks, and soils from Ekiti State in Nigeria do not pose any hazardous risk to humans, but continued monitoring is necessary when these materials are used as building materials, which cause long-term radiation exposure.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links