This study is focused on finite element analysis of a model comprising femur into which a femoral component of a total hip replacement was implanted. The considered prosthesis is fabricated from a functionally graded material (FGM) comprising a layer of a titanium alloy bonded to a layer of hydroxyapatite. The elastic modulus of the FGM was adjusted in the radial, longitudinal, and longitudinal-radial directions by altering the volume fraction gradient exponent. Four cases were studied, involving two different methods of anchoring the prosthesis to the spongy bone and two cases of applied loading. The results revealed that the FG prostheses provoked more SED to the bone. The FG prostheses carried less stress, while more stress was induced to the bone and cement. Meanwhile, less shear interface stress was stimulated to the prosthesis-bone interface in the noncemented FG prostheses. The cement-bone interface carried more stress compared to the prosthesis-cement interface. Stair climbing induced more harmful effects to the implanted femur components compared to the normal walking by causing more stress. Therefore, stress shielding, developed stresses, and interface stresses in the THR components could be adjusted through the controlling stiffness of the FG prosthesis by managing volume fraction gradient exponent.
This study focused on developing a 3D finite element model of functionally graded femoral prostheses to decrease stress shielding and to improve total hip replacement performance. The mechanical properties of the modeled functionally graded femoral prostheses were adjusted in the sagittal and transverse planes by changing the volume fraction gradient exponent. Prostheses with material changes in the sagittal and transverse planes were considered longitudinal and radial prostheses, respectively. The effects of cemented and noncemented implantation methods were also considered in this study. Strain energy and von Mises stresses were determined at the femoral proximal metaphysis and interfaces of the implanted femur components, respectively. Results demonstrated that the strain energy increased proportionally with increasing volume fraction gradient exponent, whereas the interface stresses decreased on the prostheses surfaces. A limited increase was also observed at the surfaces of the bone and cement. The periprosthetic femur with a noncemented prosthesis exhibited higher strain energy than with a cemented prosthesis. Radial prostheses implantation displayed more strain energy than longitudinal prostheses implantation in the femoral proximal part. Functionally graded materials also increased strain energy and exhibited promising potentials as substitutes of conventional materials to decrease stress shielding and to enhance total hip replacement lifespan.
A thermo-elastic contact problem of functionally graded materials (FGMs) rotating brake disk with different pure brake pad areas under temperature dependent material properties is solved by Finite Element Method (FEM). The properties of brake disk change gradually from metal to ceramic by power-law distribution along the radial direction from the inner to the outer surface. Areas of the pure pad are changing while the vertical force is constant. The ratio of brake pad thickness to FGMs brake disk thickness is assumed 0.66. Two sources of thermal loads are considered: (1) Heat generation between the pad and brake disk due to contact friction, and (2) External thermal load due to a constant temperature at inner and outer surfaces. Mechanical responses of FGMs disk are compared with several pad contact areas. The results for temperature-dependent and temperature-independent material properties are investigated and presented. The results show that the absolute value of the shear stress in temperature-dependent material can be greater than that for temperature-independent material. The radial stress for some specific grading index (n = 1.5) is compressive near the inner surface for double contact while it is tensile for a single contact. It is concluded that the radial strain for some specific value of grading index (n = 1) is lower than other FGMs and pure double side contact brake disks.
This study provides an experimental and finite element analysis of knee-joint structure during extended-knee landing based on the extracted impact force, and it numerically identifies the contact pressure, stress distribution and possibility of bone-to-bone contact when a subject lands from a safe height.
Conference abstracts: Malaysia in affiliation
(1). PO-211. AGE-SPECIFIC STRESS-MODULATED
CHANGES OF SPLENIC IMMUNOARCHITECTURE
IN THE GROWING BODY. Marina Yurievna Kapitonova, Syed Baharom Syed Ahmad Fuad, Flossie Jayakaran; Faculty of Medicine, Universiti Teknologi MARA, Shah Alam, Malaysia
syedbaharom@salam.uitm.edu.my
(2). PO-213. A DETAILED OSTEOLOGICAL STUDY OF THE ANOMALOUS GROOVES NEAR THE
MASTOID NOTCH OF THE SKULL. ISrijit Das, 2Normadiah Kassim, lAzian Latiff, IFarihah Suhaimi, INorzana Ghafar, lKhin Pa Pa Hlaing, lIsraa Maatoq, IFaizah Othman; I Department of Anatomy, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia; 2 Department of Anatomy, Universiti Malaya, Kuala Lumpur, Malaysia. das_sri jit23@rediffmail.com
(3). PO-21S. FIRST LUMBRICAL MUSCLE OF THE
PALM: A DETAILED ANATOMICAL STUDY WITH
CLINICAL IMPLICATIONS. Srijit Das, Azian Latiff, Parihah Suhaimi, Norzana Ghafar, Khin Pa Pa Hlaing, Israa Maatoq, Paizah Othman; Department of Anatomy, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia. das_srijit23@rediffmail.com
(4). PO-336. IMPROVEMENT IN EXPERIMENTALLY
INDUCED INFRACTED CARDIAC FUNCTION
FOLLOWING TRANSPLANTATION OF HUMAN
UMBILICAL CORD MATRIX-DERIVED
MESENCHYMAL CELLS. lSeyed Noureddin Nematollahi-Mahani, lMastafa Latifpour, 2Masood Deilami, 3Behzad Soroure-Azimzadeh, lSeyed
Hasan Eftekharvaghefi, 4Fatemeh Nabipour, 5Hamid
Najafipour, 6Nouzar Nakhaee, 7Mohammad Yaghoobi, 8Rana Eftekharvaghefi, 9Parvin Salehinejad, IOHasan Azizi; 1 Department of Anatomy, Kerman University of Medical Sciences, Kerman, Iran; 2 Department of Cardiosurgery, Hazrat-e Zahra Hospital, Kerman, Iran; 3 Department of Cardiology, Kerman University of Medical Sciences, Kerman, Iran; 4 Department of Pathology, Kerman University of Medical Sciences, Kerman, Iran; 5 Department of Physiology, Kerman University of Medical Sciences, Kerman, Iran; 6 Department of Neuroscience Research Center, Kerman University of Medical Sciences, Kerman, Iran; 7 Department
of Biotechnology, Research Institute of Environmental Science, International Center for Science, High Technology & Environmental Science, Kerman, Iran; 8 Students Research Center, Kerman University of Medical Sciences, Kerman, Iran; 9 Institute of Bioscience, University Putra Malaysia,
Kuala Lumpur, Malaysia; 10 Department of Stem Cell, Cell Science Research Center, Royan Institute, ACECR, Tehran, Iran. nnematollahi@kmu.ac.ir
(5).