Displaying all 5 publications

Abstract:
Sort:
  1. Wang F, Wang Y, Han Y, Cho JH
    Heliyon, 2024 Feb 15;10(3):e25484.
    PMID: 38352763 DOI: 10.1016/j.heliyon.2024.e25484
    OBJECTIVE: With the arrival of the experience economy era, changes in the marketing environment, and the evolution of consumer psychological needs, a good user experience will bring them freshness. Based on user experience, this paper analyzes the relationship among product brand image, brand trust, and brand loyalty, aiming to promote product values and improve brand loyalty and trust.

    METHODS: Through case analysis, consumers' favorite brands were selected and conducted positioning analysis on brand color, image, package form, and so on. The study proposed a hypothetical model of user experience on brand loyalty and performed a questionnaire survey on 357 consumers. The relational model of the impact of user experience on consumers was verified using the SEM (Structural Equation Model) method.

    RESULTS: It is shown that sensory experience, emotional experience, behavioral experience, and thinking experience have significant impacts on brand image; brand image apparently affects brand trust; and brand trust and image remarkably influence brand loyalty.

    CONCLUSIONS: Extending the concept of user experience to the fast-moving consumer goods industry will contribute to the package design of products and the theory and practice of brand loyalty. The research findings can provide effective strategies and approaches for marketers to improve product market competitiveness and enhance consumer brand stickiness.

  2. Ho JPY, Cho JH, Nam HS, Park SY, Lee YS
    PMID: 37975939 DOI: 10.1007/s00167-023-07660-0
    PURPOSE: The aim of this study was to identify if constitutional alignment and preoperative radiologic parameters determined whether medial gap balancing was required in mechanically aligned total knee arthroplasty (TKA).

    METHODS: Two hundred and sixty three patients with 394 consecutive knees who underwent primary TKAs were retrospectively analysed in this study. Selective sequential multiple needle puncturing (MNP) was performed for medial ligament balancing when required. Constitutional alignment, which was determined using the Coronal Plane Alignment of the Knee (CPAK) classification, as well as preoperative and postoperative radiologic parameters was evaluated to identify factors which predicted the need for MNP.

    RESULTS: One hundred and fifty eight (40.1%) knees required medial ligament balancing with MNP. Patients who required MNP during surgery had significantly more constitutional varus, more varus preoperative mechanical Hip-Knee-Ankle angle (mHKA), smaller preoperative medial proximal tibial angle (MPTA) and a larger change in mHKA and MPTA after surgery than those who did not. Patients with constitutional varus also had a higher incidence of having had MNP to both anterior and posterior superficial medial collateral ligament (sMCL) fibres. There was no significant difference in preoperative lateral distal femoral angle (LDFA), posterior tibial slope (PTS) and varus-valgus difference (VVD) between groups.

    CONCLUSION: Ligament balancing using MNP was determined by constitutional alignment rather than medial soft tissue contracture. Patients with constitutional varus who had a larger medio-lateral gap difference in extension also had a higher incidence of having had MNP to both anterior and posterior sMCL fibres.

    LEVEL OF EVIDENCE: Retrospective comparative study, level IV.

  3. Ho JPY, Cho JH, Nam HS, Park SY, Lee YS
    Knee, 2023 Dec;45:65-74.
    PMID: 37852039 DOI: 10.1016/j.knee.2023.10.002
    BACKGROUND: (1) To evaluate if referencing system affects selection of implant size, position, and gap balance in total knee arthroplasty (TKA) with the use of contemporary implant designs and (2) to describe the authors' intraoperative sizing strategy using anterior referencing (AR) and posterior referencing (PR) systems.

    METHODS: This was a retrospective review of 270 consecutive patients (397 knees) who underwent primary TKA with an AR or PR system. Selection of implant size, mediolateral and anteroposterior alignment of the femoral component, as well as gaps were compared between groups.

    RESULTS: In the AR group, more patients had femoral components which were upsized or downsized compared to those in the PR group (29.5% vs 12.0% respectively) and in patients who underwent bilateral TKA, 49.4% of those in the AR group had femur component size asymmetry. The AR group had better medio-lateral (ML) fit over the distal cutting surface area, smaller change in anterior offset but higher incidence of anterior notching when compared to the PR group. Posterior condylar offset (PCO) was restored in both groups and gap differences in flexion-extension and ML were comparable. There was also no difference in clinical scores and ROM between groups at 2-years follow-up.

    CONCLUSION: In this study, conventional implications related to referencing system were not observed. In practice, AR systems can restore PCO while PR systems do not result in increased anterior notching or anterior overstuffing. Differences observed in this study are most likely related to implant design specifics and surgical technique.

  4. Ho JPY, Park SY, Nam HS, Cho JH, Lee YS
    Knee, 2023 Dec;45:35-45.
    PMID: 37774563 DOI: 10.1016/j.knee.2023.09.003
    BACKGROUND: The aims of this study were (1) to compare in vivo coverage and rotational alignment of 2 tibial component designs: anatomic and symmetrical; and (2) to determine if coronal deformity and tibial torsion were related to rotation and coverage.

    METHODS: Postoperative CT scans of 200 propensity score-matched patients who underwent TKA with either an anatomic (ATC) or symmetrical tibia component (STC) were analyzed. Rotation was measured using four axes: surgical transepicondylar axis (sTEA), Berger's protocol, medio-lateral (ML) axis and posterior borders of the tibial plateau, while coverage was assessed by measuring fit and surface area. The relationship between coronal deformity, tibial torsion, rotation, and coverage was investigated.

    RESULTS: Overall, STCs had more internal rotation when measured using the sTEA (-0.6° ± 3.5 vs 0.5° ± 3.6, p = 0.03), Berger's protocol (-21.6° ± 7.1 vs -17.9° ± 6.2, p = 0.000) and ML axes (2.9° ± 3.9 vs 8.1° ± 5.1, p = 0.000) compared to ATCs. STCs also had more posteromedial underhang (-3.3 mm ± 2.4 mm vs -1.7 mm ± 2.5 mm, p = 0.000) but smaller change in tibial torsion postoperatively (-18.4° ± 9.9° vs -13.1° ± 9.4°, p = 0.000). Tibial torsion was more pronounced in valgus than varus knees both preoperative (-25.4° ± 6.5° vs -20.2° ± 9.3°, p = 0.02) and postoperatively (-19.7° ± 7.2° vs -14.7° ± 10.3°, p = 0.04), but there was no difference in postoperative tibial torsion between ATCs and STCs in this subgroup.

    CONCLUSION: The use of an anatomic tibial baseplate optimizes coverage by reducing posterolateral overhang and posteromedial underhang. It also achieved better rotational profiles compared to STCs. However, it resulted in a larger change in tibial torsion after TKA.

  5. Mengesha MG, Rajasekaran S, Ramachandran K, Sengodan VC, Yasin NF, Williams LM, et al.
    J Orthop, 2024 Sep;55:97-104.
    PMID: 38681829 DOI: 10.1016/j.jor.2024.04.018
    PURPOSE: Improper utilization of surgical antimicrobial prophylaxis frequently leads to increased risks of morbidity and mortality.This study aims to understand the common causative organism of postoperative orthopedic infection and document the surgical antimicrobial prophylaxis protocol across various institutions in to order to strengthen surgical antimicrobial prophylaxis practice and provide higher-quality surgical care.

    METHODS: This multicentric multinational retrospective study, includes 24 countries from five different regions (Asia Pacific, South Eastern Africa, Western Africa, Latin America, and Middle East). Patients who developed orthopedic surgical site infection between January 2021 and December 2022 were included. Demographic details, bacterial profile of surgical site infection, and antibiotic sensitivity pattern were documented.

    RESULTS: 2038 patients from 24 countries were included. Among them 69.7 % were male patients and 64.1 % were between 20 and 60 years. 70.3 % patients underwent trauma surgery and instrumentation was used in 93.5 %. Ceftriaxone was the most common preferred in 53.4 %. Early SSI was seen in 55.2 % and deep SSI in 59.7 %. Western Africa (76 %) and Asia-Pacific (52.8 %) reported a higher number of gram-negative infections whereas gram-positive organisms were predominant in other regions. Most common gram positive organism was Staphylococcus aureus (35 %) and gram-negative was Klebsiella (17.2 %). Majority of the organisms showed variable sensitivity to broad-spectrum antibiotics.

    CONCLUSION: Our study strongly proves that every institution has to analyse their surgical site infection microbiological profile and antibiotic sensitivity of the organisms and plan their surgical antimicrobial prophylaxis accordingly. This will help to decrease the rate of surgical site infection, prevent the emergence of multidrug resistance and reduce the economic burden of treatment.