Displaying all 18 publications

Abstract:
Sort:
  1. Azmi MI, Nair AK, Hashim SA
    Innovations (Phila), 2024;19(2):175-183.
    PMID: 38577864 DOI: 10.1177/15569845241238999
    OBJECTIVE: We evaluated the effectiveness of a consistent and structured self-practice coronary anastomosis program using a homemade low-fidelity beating-heart simulator.

    METHODS: An intermediary trainee was subjected to an 8-week structured self-practice program. The program was divided into 2 parts of nonbeating and beating practices with a minimum number of timed anastomoses. Each part was followed by an assessment using an objective skills assessment tool score. The beating-heart simulator was built using motorized toy blocks connected wirelessly to a smartphone application. This was coded to enable rate selection. A junior consultant was compared to the subject at the end of the program. Both were tasked to perform 1 coronary anastomosis for both off-pump coronary artery bypass (OPCAB) and minimally invasive CAB (MICS) setup. The primary outcomes were anastomotic time and score compared with the junior consultant. Secondary outcomes were progression of anastomotic time and score throughout the program.

    RESULTS: Overall performance of the studied subject approached the performance of the junior consultant in terms of time (OPCAB, 489 vs 605 s; MICS, 712 vs 652 s) and scores (OPCAB, 21 vs 20.7; MICS, 19 vs 20.6). There were inverse correlations between anastomosis time and number of practices for both nonbeating and beating anastomoses. Overall improvement was observed in terms of assessment scoring by 26.6%.

    CONCLUSIONS: A structured self-practice program using an affordable and accessible simulator was able to help trainees overcome the MICS anastomosis learning curve quicker when introduced earlier. This may encourage earlier adoption of MICS among surgeons.

  2. Krishnasamy S, Krishna Nair A, Hashim SA, Raja Mokhtar RA
    Interact Cardiovasc Thorac Surg, 2019 12 01;29(6):976-977.
    PMID: 31363757 DOI: 10.1093/icvts/ivz191
    Liposarcoma is the second most common type of soft tissue malignancy in adults. They are malignant tumours with a mesenchymal origin. Mediastinal liposarcoma accounts for <1% of mediastinal tumours and 2% of liposarcoma. We report a patient with mediastinal liposarcoma who presented with cardiac tamponade, 25 years after the initial liposarcoma in the popliteal fossa.
  3. Ramli FF, Azizi MH, Syed Hashim SA
    Int J Med Sci, 2021;18(11):2372-2380.
    PMID: 33967614 DOI: 10.7150/ijms.57641
    Sexual dysfunction is a common condition in the opioid substitution therapy (OST) population. We aimed to determine the efficacy and safety of treatment for sexual dysfunction in the OST population. We searched for interventional studies from Medline, PubMed, and Scopus. Three independent authors conducted a risk-of-bias assessment (RoB 2). A total of seven studies (five randomized-controlled trials, two quasi-experimental), including 473 patients with sexual dysfunction, were identified. Among these, three bupropion (n=207), one trazodone (n=75), two rosa Damascena (n=100), and one ginseng (n=91) studies had reported significantly improve various sexual functioning domains in both genders. In a meta-analysis, bupropion significantly increased male sexual function with standardized mean difference of 0.53; 95% confidence interval of 0.19-0.88; P < 0.01; I2=0. The adverse effects were minor for all agents, and no significant difference between treatment and placebo groups in randomized-controlled trials. These agents have a promising future as therapy for sexual dysfunction in the OST population. However, given the limited sample size and number of studies, further studies should be conducted to confirm the use of these agents.
  4. Ramli FF, Syed Hashim SA, Mohd Effendy N
    Int J Med Sci, 2021;18(2):575-581.
    PMID: 33390827 DOI: 10.7150/ijms.52201
    Background: Long-term opioid therapy is a risk factor for low bone mineral density (BMD). However, other factors may also contribute to low BMD. Several studies have examined the variables that might contribute to low BMD in patients receiving opioid replacement therapy (OST). However, to our knowledge, there was no systemic review conducted to address this particular issue. Thus, we reviewed the articles on the factors associated with low BMD in the population of opioid use disorder receiving substitution therapy. Methods: The articles that examined correlates or risk factors of low BMD in OST population were retrieved from OVID, SCOPUS, and PUBMED from inception until July 2020 by two independent investigators. Results: A total of 429 articles from three databases were retrieved initially. After screening based on eligibility criteria, five articles were included in the final analysis. The risk factors or correlates found to be significantly associated with low BMD in the OST population include male gender, low body mass index, low testosterone level, methadone or heroin use, and longer duration of heavy alcohol use. The review limitations include small sample sizes and inconsistent definition of variables. Conclusion: OST patients should be screened for BMD and its associated factors. Guidelines and training of practitioners involving in the OST service should be provided to increase the detection of low BMD in the OST population.
  5. Wan Ab Naim WN, Ganesan PB, Sun Z, Chee KH, Hashim SA, Lim E
    ScientificWorldJournal, 2014;2014:652520.
    PMID: 24672348 DOI: 10.1155/2014/652520
    Aortic dissection, characterized by separation of the layers of the aortic wall, poses a significant challenge for clinicians. While type A aortic dissection patients are normally managed using surgical treatment, optimal treatment strategy for type B aortic dissection remains controversial and requires further evaluation. Although aortic diameter measured by CT angiography has been clinically used as a guideline to predict dilation in aortic dissection, hemodynamic parameters (e.g., pressure and wall shear stress), geometrical factors, and composition of the aorta wall are known to substantially affect disease progression. Due to the limitations of cardiac imaging modalities, numerical simulations have been widely used for the prediction of disease progression and therapeutic outcomes, by providing detailed insights into the hemodynamics. This paper presents a comprehensive review of the existing numerical models developed to investigate reasons behind tear initiation and progression, as well as the effectiveness of various treatment strategies, particularly the stent graft treatment.
  6. Hashim SA, Samsudin FN, Wong CS, Abu Bakar K, Yap SL, Mohd Zin MF
    Arch Biochem Biophys, 2016 09 01;605:34-40.
    PMID: 27056469 DOI: 10.1016/j.abb.2016.03.032
    A modular typed dielectric barrier discharge (DBD) device is designed and tested for air and water remediation. The module is made of a number of DBD tubes that can be arranged in series or parallel. Each of the DBD tubes comprises inner electrode enclosed with dielectric barrier and arranged as such to provide a gap for the passage of gases. Non-thermal plasma generated in the gap effectively creates gaseous chemical reactions. Its efficacy in the remediation of gas stream containing high NOx, similar to diesel emission and wastewater containing latex, are presented. A six tubes DBD module has successfully removed more than 80% of nitric oxide from the gas stream. In another arrangement, oxygen was fed into a two tubes DBD to generate ozone for treatment of wastewater. Samples of wastewater were collected from a treatment pond of a rubber vulcanization pilot plant. The water pollution load was evaluated by the chemical oxygen demand (COD) and biological oxygen demand (BOD5) values. Preliminary results showed some improvement (about 13%) on the COD after treatment and at the same time had increased the BOD5 by 42%. This results in higher BOD5/COD ratio after ozonation which indicate better biodegradability of the wastewater.
  7. Johari B, Abdul Aziz YF, Krishnasamy S, Looi LM, Hashim SA, Raja Mokhtar RA
    Iran J Radiol, 2015 Apr;12(2):e11197.
    PMID: 26060549 DOI: 10.5812/iranjradiol.11197
    The presence of tumor thrombus in the right atrium is frequently the result of direct intraluminal extension of infra-diaphragmatic malignancy into the inferior vena cava (IVC) or supradiaphragmatic carcinoma into the superior vena cava (SVC). Right atrial tumor thrombus with extension into both SVC and IVC has not been reported in the literature. We present a patient who presented with symptoms of right atrial and SVC obstruction. Imaging revealed presence of a thrombus in the right atrium, extending to the SVC and IVC, with the additional findings of a left adrenal mass and multiple liver lesions. The histopathological examination of the right atrial mass revealed metastatic adenocarcinoma cells. The patient was given a presumptive diagnosis of metastatic adenocarcinoma, most likely adrenal in origin, with multiple hepatic lesions suspicious for metastasis. The clinical outcome of the patient was not favorable; the patient succumbed before the adrenal mass could be confirmed to be the primary tumor. This case highlights that in patients manifesting with extensive cavoatrial thrombus as, the existence of primary carcinoma should be considered especially in the adrenal cortex or in the lung.
  8. Hashim SA, Amin MA, Nair A, Raja Mokhtar RA, Krishnasamy S, Cheng K
    Heart Lung Circ, 2018 May;27(5):e59-e63.
    PMID: 29246681 DOI: 10.1016/j.hlc.2017.11.011
    The revision of an internal mammary artery graft anastomosis because of a technical error can be time-consuming and complicated and may lead to complications. Here, we describe the technical details and our early experience of using a standard transit-time flowmeter to exclude technical errors and facilitate rapid decision making for anastomosis revision in an arrested heart during aortic cross-clamping in the absence of ultrasound guidance.
  9. Krishnasamy S, Sahid SM, Hashim SA, Singh S, Chung F, Mokhtar RAR, et al.
    J Thorac Dis, 2019 Dec;11(12):5453-5462.
    PMID: 32030264 DOI: 10.21037/jtd.2019.11.44
    Background: Obstructive sleep apnea (OSA) is a serious health disorder which contributes to cardiovascular complications, decreased work productivity, automobile accidents, and death. This condition is characterized by a temporary cessation of breathing resulting due to upper airway closure during a person's sleep. Strain to the heart caused by this repetitive hypoxic insult can lead to postoperative complications for patients undergoing heart surgery. Recognizing cardiac surgical patients with OSA is important. Early recognition and intervention such as use of BiPAP device can reduce the postoperative complications due to OSA.

    Methods: The aim of this study is to identify the incidence of unrecognized OSA in cardiac surgical patients. This is a retrospective analysis of a prospective data of the study which was done between July 2012 and July 2013 in University Malaya Medical Center. All patients undergoing elective cardiac surgery were recruited and the demographic data, questionnaire and the portable sleep study results were obtained. Patients were followed up till 30 days to record any complications. Data were entered in SPSS version 17 and analysis was done.

    Results: The incidence of OSA was 61.4% and 43.5% were moderate to severe OSA. There was male predominance of OSA (79%) with a mean age of 60 years. OSA subjects had shorter inter-incisor distance (4.18±0.6 cm) and larger waistline (94.1±12.1 cm). The STOP-Bang questionnaire has a sensitivity of 75.8% in predicting apnoa-hypopnea index (AHI) ≥5/hour.

    Conclusions: OSA can be diagnosed with a simple screening questionnaire and a bedside portable sleep study. Cardiac patients diagnosed with OSA can be pre-emptively given extra attention in managing their postoperative care.

  10. Hashim SA, Mohd Yusof BN, Abu Saad H, Ismail S, Hamdy O, Mansour AA
    Clin Nutr ESPEN, 2021 Oct;45:141-149.
    PMID: 34620310 DOI: 10.1016/j.clnesp.2021.07.024
    BACKGROUND & AIMS: The study aimed to evaluate the effectiveness of the Simplified Diabetes Nutrition Education (SDNE) on glycemic control and other diabetes-related outcomes in patients with type 2 diabetes mellitus (T2DM).

    METHODS: This a randomized controlled trial (RCT) randomized 208 patients with T2DM [mean age = 48.8 ± 11.8 years, Glycated Hemoglobin (HbA1c) = 9.5 ± 2.4%, and Body Mass Index = 28.0 ± 5.6 kg/m2] to intervention group (n = 104) or control group (n = 104). Participants in the intervention group received a weekly diabetes nutrition module based on the health belief model for 12 weeks in addition to the usual care whereas the control participants were given the usual care. We evaluated HbA1c and diabetes-related outcomes (metabolic parameters, dietary intake, and physical activity level) at baseline, 12 weeks, and 22 weeks. Health beliefs, diabetes knowledge, and health literacy were also evaluated.

    RESULTS: After 22 weeks, HbA1c improved significantly in the intervention group (-1.7%) from the baseline value, compared to the control group (+0.01%) (p 

  11. Hashim SA, Barakatun-Nisak MY, Abu Saad H, Ismail S, Hamdy O, Mansour AA
    Nutrients, 2020 Oct 15;12(10).
    PMID: 33076406 DOI: 10.3390/nu12103152
    While the role of medical and nutrition factors on glycemic control among adults with type 2 diabetes mellitus (T2DM) has been well-established, the association between health literacy (H.L.) and glycemic control is inconsistent. This study aims to determine the association of H.L. and nutritional status assessments with glycemic control in adults with type 2 diabetes mellitus. A total of 280 T2DM respondents (mean (SD) age = 49.7 (10.3) years, Glycated hemoglobin (HbA1c) = 9.9 (2.6) %, and Body Mass Index = 32.7 (15.1) kg/m2) were included in this study. A short-form Test of Functional Health Literacy in Adults (S-TOFHLA) assessed the H.L. levels. Nutritional status assessments included client history, glycemic control, anthropometric, and biochemical data. The mean (S.D.) H.L. score was 45.7 (24.6), with 56% of the respondents had inadequate H.L. Inadequate H.L. was more common among those females; housewives, low education, received oral antidiabetic therapy, and shorter diabetes duration. Respondents with inadequate H.L. were significantly older and had higher HbA1c than those with marginal and adequate H.L. Meanwhile, respondents with inadequate and marginal H.L. levels had significantly higher total cholesterol, LDL-cholesterol, and systolic blood pressure than the respondents with adequate H.L. Low H.L. scores, self-employment status, received dual antidiabetic therapy (insulin with oral agents), received insulin alone, and had higher fasting blood glucose explained about 21% of the total variation in HbA1c (adjusted R2 = 0.21; p < 0.001). Respondents with inadequate H.L. had poor glycemic control. The H.L. scores, together with nutritional status assessments, were the factors that predicted poor glycemic control among adults with T2DM.
    Study site: Faiha Specialized Diabetes, Endocrine, and Metabolism Centre (FDEMC), Basrah, Iraq
  12. Ramli FF, Ali A, Syed Hashim SA, Kamisah Y, Ibrahim N
    PMID: 34769806 DOI: 10.3390/ijerph182111289
    Despite its severe adverse effects, such as agranulocytosis, clozapine is the primary treatment for treatment-resistant schizophrenia. The established clozapine monitoring system has contributed to reducing agranulocytosis incidence and mortality rates. However, the pandemic coronavirus disease 2019 (COVID-19) has caused changes in the monitoring system. This review aimed to assess the current evidence on the neutrophil changes in the patient on clozapine treatment and infected with COVID-19. Individual cases reported various absolute neutrophil count (ANC) levels, normal, reduced, or elevated. No agranulocytosis case was reported. One case had a borderline moderate-severe ANC level, but the patient was in the 18-week period of clozapine treatment. A cumulative analysis of case the series initially reported inconclusive results. However, a more recent study with a larger sample size reported a significant reduction in the ANC during COVID-19 infection. Nevertheless, this effect is transient as no significant difference was found between the baseline and the post-infection period in ANC levels. In conclusion, COVID-19 is associated with a temporary reduction in ANC levels. The results supported the recommendation to reduce the frequency of clozapine monitoring in the eligible candidates. However, more data are required to confirm the current findings given the limitations, including study design, sample size, and statistical analysis.
  13. Lau I, Wong YH, Yeong CH, Abdul Aziz YF, Md Sari NA, Hashim SA, et al.
    Quant Imaging Med Surg, 2019 Jan;9(1):107-114.
    PMID: 30788252 DOI: 10.21037/qims.2019.01.02
    Current visualization techniques of complex congenital heart disease (CHD) are unable to provide comprehensive visualization of the anomalous cardiac anatomy as the medical datasets can essentially only be viewed from a flat, two-dimensional (2D) screen. Three-dimensional (3D) printing has therefore been used to replicate patient-specific hearts in 3D views based on medical imaging datasets. This technique has been shown to have a positive impact on the preoperative planning of corrective surgery, patient-doctor communication, and the learning experience of medical students. However, 3D printing is often costly, and this impedes the routine application of this technology in clinical practice. This technical note aims to investigate whether reducing 3D printing costs can have any impact on the clinical value of the 3D-printed heart models. Low-cost and a high-cost 3D-printed models based on a selected case of CHD were generated with materials of differing cost. Quantitative assessment of dimensional accuracy of the cardiac anatomy and pathology was compared between the 3D-printed models and the original cardiac computed tomography (CT) images with excellent correlation (r=0.99). Qualitative evaluation of model usefulness showed no difference between the two models in medical applications.
  14. Chin KY, Ng BN, Rostam MKI, Muhammad Fadzil NFD, Raman V, Mohamed Yunus F, et al.
    J Clin Med, 2022 Oct 30;11(21).
    PMID: 36362662 DOI: 10.3390/jcm11216434
    Osteoporosis refers to excessive bone loss as reflected by the deterioration of bone mass and microarchitecture, which compromises bone strength. It is a complex multifactorial endocrine disease. Its pathogenesis relies on the presence of several endogenous and exogenous risk factors, which skew the physiological bone remodelling to a more catabolic process that results in net bone loss. This review aims to provide an overview of osteoporosis from its biology, epidemiology and clinical aspects (detection and pharmacological management). The review will serve as an updated reference for readers to understand the basics of osteoporosis and take action to prevent and manage this disease.
  15. Wan Ab Naim WN, Ganesan PB, Sun Z, Lei J, Jansen S, Hashim SA, et al.
    Int J Numer Method Biomed Eng, 2018 05;34(5):e2961.
    PMID: 29331052 DOI: 10.1002/cnm.2961
    Endovascular stent graft repair has become a common treatment for complicated Stanford type B aortic dissection to restore true lumen flow and induce false lumen thrombosis. Using computational fluid dynamics, this study reports the differences in flow patterns and wall shear stress distribution in complicated Stanford type B aortic dissection patients after endovascular stent graft repair. Five patients were included in this study: 2 have more than 80% false lumen thrombosis (group 1), while 3 others had less than 80% false lumen thrombosis (group 2) within 1 year following endovascular repair. Group 1 patients had concentrated re-entry tears around the abdominal branches only, while group 2 patients had re-entry tears that spread along the dissection line. Blood flow inside the false lumen which affected thrombus formation increased with the number of re-entry tears and when only small amounts of blood that entered the false lumen exited through the branches. In those cases where dissection extended below the abdominal branches (group 2), patients with fewer re-entry tears and longer distance between the tears had low wall shear stress contributing to thrombosis. This work provides an insight into predicting the development of complete or incomplete false lumen thrombosis and has implications for patient selection for treatment.
  16. Wan Ab Naim WN, Sun Z, Liew YM, Chan BT, Jansen S, Lei J, et al.
    Quant Imaging Med Surg, 2021 May;11(5):1723-1736.
    PMID: 33936960 DOI: 10.21037/qims-20-814
    Background: The study aims to analyze the correlation between the maximal diameter (both axial and orthogonal) and volume changes in the true (TL) and false lumens (FL) after stent-grafting for Stanford type B aortic dissection.

    Method: Computed tomography angiography was performed on 13 type B aortic dissection patients before and after procedure, and at 6 and 12 months follow-up. The lumens were divided into three regions: the stented area (Region 1), distal to the stent graft to the celiac artery (Region 2), and between the celiac artery and the iliac bifurcation (Region 3). Changes in aortic morphology were quantified by the increase or decrease of diametric and volumetric percentages from baseline measurements.

    Results: At Region 1, the TL diameter and volume increased (pre-treatment: volume =51.4±41.9 mL, maximal axial diameter =22.4±6.8 mm, maximal orthogonal diameter =21.6±7.2 mm; follow-up: volume =130.7±69.2 mL, maximal axial diameter =40.1±8.1 mm, maximal orthogonal diameter =31.9+2.6 mm, P<0.05 for all comparisons), while FL decreased (pre-treatment: volume =129.6±150.5 mL; maximal axial diameter =43.0±15.8 mm; maximal orthogonal diameter =28.3±12.6 mm; follow-up: volume =66.6±95.0 mL, maximal axial diameter =24.5±19.9 mm, maximal orthogonal diameter =16.9±13.7, P<0.05 for all comparisons). Due to the uniformity in size throughout the vessel, high concordance was observed between diametric and volumetric measurements in the stented region with 93% and 92% between maximal axial diameter and volume for the true/false lumens, and 90% and 92% between maximal orthogonal diameter and volume for the true/false lumens. Large discrepancies were observed between the different measurement methods at regions distal to the stent graft, with up to 46% differences between maximal orthogonal diameter and volume.

    Conclusions: Volume measurement was shown to be a much more sensitive indicator in identifying lumen expansion/shrinkage at the distal stented region.