Displaying all 4 publications

Abstract:
Sort:
  1. Fateh, A., Hejazi, F., Ramanathan, R.A., Jaffar, M.S.
    MyJurnal
    The use of the Light Rail Transit (LRT) system is currently preferred because LRT is sustainable,
    improves travel options and facilitates swift mobility in urban areas. Hence, the structural stability
    and safety of this public transportation system against seismic occurrences are indispensable. Given
    that these structures cannot be considered conventional frames because of their complex architectural
    design, focussing meticulously on reliable seismic design codes and structural rehabilitation techniques
    is vital for the design of the lateral resistance system. One Malaysian LRT station is considered in this
    study, and the seismic response of this train station when equipped with supplementary viscous damper
    devices is evaluated. Thus, the LRT station is modelled through finite element simulation. The methods
    of seismic analysis are limited to linear seismic analyses, namely, response spectrum and time history
    analyses. Results derived in this study show a significant improvement in structural response when the
    station is fitted with dampers; approximately 40% reduction in displacement is observed at the top joint
    of the roof. Furthermore, the lateral base shears decrease by approximately 70%.
  2. Ziaee M, Hejazi F
    PLoS One, 2023;18(8):e0290248.
    PMID: 37590241 DOI: 10.1371/journal.pone.0290248
    Coulomb friction is considered as a mechanical approach to diminish the structural responses during the excitations. However, in case of severe oscillations supplementary mechanisms are employed besides the friction to mitigate the destructive effects of the vibrations in structures. Therefore, the main goal of this research is to develop a new Hybrid System (HS) which is a parallel combination of Viscous Damping (VD) and Coulomb friction for structures subjected to dynamic load. To achieve this goal, the effect of viscous damper is embedded in the equation of motion which is proposed by Den Hartog for a Single-Degree-of-Freedom (SDOF) Coulomb system, and has been extensively implemented for past few decades. In the considered numerical example in this study, implementing the proposed HDM in system resulted in decreasing the maximum displacement in the range of 1% to 98% for different amounts of force amplitude and viscous damping ratios. Also, applying the proposed HDM increased the time lag for about up to 24% for the frequency ratios greater than 1. The developed hybridized system in this study can be utilised as new generation of Tuned Mass Damper (TMD) to improve their energy dissipating efficiency under severe excitations.
  3. Lai VY, Hejazi F, Saleem S
    PLoS One, 2020;15(11):e0238654.
    PMID: 33147216 DOI: 10.1371/journal.pone.0238654
    Towers are important structures for installing radio equipment to emit electromagnetic waves that allow radio, television and/or mobile communications to function. Feasibility, cost, and speed of the construction are considered in the design process as well as providing stability and functionality for the communication tower. This study proposes the new design for construction of segmental tubular section communication tower with ultra-high-performance fibre concrete (UHPFC) material and prestress tendon to gain durability, ductility, and strength. The proposed mix design for UHPFC in this study which used for construction of communication tower is consisted of densified Silica Fume, Silica fine and coarse Sand and hooked-ends Steel Fiber. The prestressed tendon is used in the tower body to provide sufficient strength against the lateral load. The proposed design allows the tower to be built with three precast segments that are connected using bolts and nuts. This paper presents a novel method of construction and installation of the communication tower. The advantages of proposed design and construction process include rapid casting of the precast segment for the tower and efficient installation of segments in the project. The use of UHPFC material with high strength and prestress tendon can reduce the size and thickness of the tower as well as the cost of construction. Notably, this material can also facilitate the construction and installation procedure.
  4. Zainal SMIS, Hejazi F, Aziz FNAA, Jaafar MS
    Materials (Basel), 2020 Nov 10;13(22).
    PMID: 33182531 DOI: 10.3390/ma13225055
    The use of fibers in cementitious composites yields numerous benefits due to their fiber-bridging capabilities in resisting cracks. Therefore, this study aimed to improve the shear-resisting capabilities of conventional concrete through the hybridization of multiple synthetic fibers, specifically on reinforced concrete structures in seismic-prone regions. For this study, 16 hybrid fiber-reinforced concretes (HyFRC) were developed from the different combinations of Ferro macro-synthetic fibers with the Ultra-Net, Super-Net, Econo-Net, and Nylo-Mono microfibers. These hybrids were tested under direct shear, resulting in improved shear strength of controlled specimens by Ferro-Ultra (32%), Ferro-Super (24%), Ferro-Econo (44%), and Ferro-Nylo (24%). Shear energy was further assessed to comprehend the effectiveness of the fiber interactions according to the mechanical properties, dosage, bonding power, manufactured material, and form of fibers. Conclusively, all fiber combinations used in this study produced positive synergistic effects under direct shear at large crack deformations.