  1. Isa IN, Dom SM
    J Vet Med Sci, 2016 Oct 1;78(9):1399-1403.
    PMID: 27211519
    Elevated temperatures can induce changes in red blood cell (RBC), white blood cell (WBC) and platelet (PLT) counts. Ultrasound heating during obstetric scans has the potential to increase body temperature owing to the phenomenon of absorption. We conducted a study to determine the thermal effects of prenatal ultrasound on RBCs, hemoglobin concentration (Hb), WBCs and PLTs in young rabbits. We selected 69 rabbits that were 1 month of age and 73 that were 5 months of age, and allocated them to four groups. The control group consisted of four pregnant does that were allowed to have a full term delivery without any ultrasound exposure. The experimental groups were subjected to one-time ultrasound exposure for 30, 60 and 90 min in the middle of each gestational stage accordingly. RBCs and Hb showed significant reductions in the experimental groups of 1- and 5-month-old rabbits (P<0.05). In addition, WBCs and PLTs yielded significant differences in the 1-month group that were not observed in the 5-month group (P>0.05). The highest values recorded were those of the WBCs of 1-month-old subjects that received 90 min of exposure at the second stage of gestation. The PLTs were the lowest values recorded in 1-month-old subjects following 90 min of ultrasound exposure at the third stage of gestation. These findings suggest that hematological fluctuations during the early stages of postnatal life persisted until 1 month of age and recovered thereafter, as the subjects progressed into adulthood. Therefore, ultrasound heating can cause significant, yet reversible effects on the hematological parameters of rabbits.
  2. Abdulwahid Mohammad Noor K, Mohd Norsuddin N, Che Isa IN, Abdul Karim MK
    Radiography (Lond), 2024 May 08;30(4):1041-1052.
    PMID: 38723445 DOI: 10.1016/j.radi.2024.04.019
    INTRODUCTION: Breast imaging plays a crucial role in the early detection and management of breast cancer, with visual quality, modality innovation and diagnostic performance being key factors in achieving accurate diagnoses and optimal patient outcomes. This paper presents a comprehensive bibliometric analysis of the literature on the three above elements focusing on breast imaging, aiming to uncover publication trends, identify influential works and authors, and highlight future research directions.

    METHODS: We employed a methodical bibliometric approach, making use of Scopus and Web of Science (WoS) databases for gathering literatures. We planned our search strategy, concentrating on terms linked to "breast imaging," "image quality," and "diagnostic accuracy" to ensure a systematic examination of the subject. The enhanced search functions in these databases enabled us to narrow down and improve our findings, choosing only the articles, conference papers, and book sections that are most relevant. After conducting a thorough screening process to remove duplicates and evaluate significance, we utilized ScientoPy and VOSviewer software for an in-depth bibliometric analysis. This helped to explore trends in publications, patterns of citations, and thematic groups, giving us a better understanding of how the field has changed and where it currently stands. Our approach prioritized assessing methodological quality and bias in the studies we included, guaranteeing the reliability of our findings.

    RESULTS: We reviewed 2984 relevant publications, revealing a consistent annual growth rate of 2.8% in breast imaging research, with the United States and Europe leading in contributions. The study found that advancements in radiological technologies and international collaboration are driving forces behind the field's expansion. Key subject areas such as 'Radiology, Nuclear Medicine, and Medical Imaging' dominated, underscoring their impact on diagnostic quality. Notable authors and institutions have been identified for their influential research, characterized by high citation metrics and significant scholarly impact.

    CONCLUSION: The study shows a continuous increase in research on breast imaging, considered by new technologies and teamwork defining the present time. The assessment highlights a key move towards utilizing digital imaging methods and computational analysis, affecting the improvement of future diagnostic procedures and patients' results. The study highlights the importance of continued international collaborations to tackle the new barriers in breast imaging and make the most of technological progress.

    IMPLICATIONS FOR PRACTICE: This study shows a focus on using interdisciplinary methods and cutting-edge technology in breast imaging to help healthcare professionals improve their performance and accuracy in diagnosis. Recognizing vital research and emerging trends should guide clinical guidelines, radiology training, and patient care plans to encourage the use of effective techniques and stimulate innovation in diagnostic approaches.

  3. Harun HH, Abdul Karim MK, Abd Rahman MA, Abdul Razak HR, Che Isa IN, Harun F
    Diagnostics (Basel), 2020 Sep 09;10(9).
    PMID: 32916913 DOI: 10.3390/diagnostics10090680
    This study aimed to establish the local diagnostic reference levels (LDRLs) of computed tomography pulmonary angiography (CTPA) examinations based on body size with regard to noise magnitude as a quality indicator. The records of 127 patients (55 males and 72 females) who had undergone CTPAs using a 128-slice CT scanner were retrieved. The dose information, scanning acquisition parameters, and patient demographics were recorded in standardized forms. The body size of patients was categorized into three groups based on their anteroposterior body length: P1 (14-19 cm), P2 (19-24 cm), and P3 (24-31 cm), and the radiation dose exposure was statistically compared. The image noise was determined quantitatively by measuring the standard deviation of the region of interest (ROI) at five different arteries-the ascending and descending aorta, pulmonary trunk, and the left and right main pulmonary arteries. We observed that the LDRL values were significantly different between body sizes (p < 0.05), and the median values of the CT dose index volume (CTDIvol) for P1, P2, and P3 were 6.13, 8.3, and 21.40 mGy, respectively. It was noted that the noise reference values were 23.78, 24.26, and 23.97 HU for P1, P2, and P3, respectively, which were not significantly different from each other (p > 0.05). The CTDIvol of 9 mGy and dose length product (DLP) of 329 mGy∙cm in this study were lower than those reported by other studies conducted elsewhere. This study successfully established the LDRLs of a local healthcare institution with the inclusion of the noise magnitude, which is comparable with other established references.
  4. Haniff NSM, Abdul Karim MK, Osman NH, Saripan MI, Che Isa IN, Ibahim MJ
    Diagnostics (Basel), 2021 Aug 30;11(9).
    PMID: 34573915 DOI: 10.3390/diagnostics11091573
    Hepatocellular carcinoma (HCC) is considered as a complex liver disease and ranked as the eighth-highest mortality rate with a prevalence of 2.4% in Malaysia. Magnetic resonance imaging (MRI) has been acknowledged for its advantages, a gold technique for diagnosing HCC, and yet the false-negative diagnosis from the examinations is inevitable. In this study, 30 MR images from patients diagnosed with HCC is used to evaluate the robustness of semi-automatic segmentation using the flood fill algorithm for quantitative features extraction. The relevant features were extracted from the segmented MR images of HCC. Four types of features extraction were used for this study, which are tumour intensity, shape feature, textural feature and wavelet feature. A total of 662 radiomic features were extracted from manual and semi-automatic segmentation and compared using intra-class relation coefficient (ICC). Radiomic features extracted using semi-automatic segmentation utilized flood filling algorithm from 3D-slicer had significantly higher reproducibility (average ICC = 0.952 ± 0.009, p < 0.05) compared with features extracted from manual segmentation (average ICC = 0.897 ± 0.011, p > 0.05). Moreover, features extracted from semi-automatic segmentation were more robust compared to manual segmentation. This study shows that semi-automatic segmentation from 3D-Slicer is a better alternative to the manual segmentation, as they can produce more robust and reproducible radiomic features.
  5. Mohamed A, Mat Sanusi NSA, Azman NS, Zailani NS, Jasmin NH, Che Isa IN
    Radiography (Lond), 2024 Jan;30(1):388-393.
    PMID: 38159357 DOI: 10.1016/j.radi.2023.12.006
    INTRODUCTION: Postgraduate education in medical imaging is an important platform that can support in preparing radiographers for the role extension and advancement in radiography. Thus, this study aims to identify the factors influencing final year radiography students' intention to pursue postgraduate education in medical imaging.

    METHODS: An online cross-sectional survey was conducted among final year students in medical imaging programs from six institutions in Malaysia. Purposive convenience sampling has been employed. Data collection was related to students' interest in postgraduate study and possible factors that may affect students' intention to pursue postgraduate education after study degree completion. The questionnaire was a combination of a Likert Scale and open-ended question.

    RESULTS: A total of 148 (female, n = 132 and male, n = 16) responses were included in the analysis. Among the participants, n = 93 (62.8 %) of students intended to pursue study. The highest choice of study was mixed mode (41.9 %) and cardiac imaging was the field of choice by the students (22.3 %). Five factors have been found to significantly correlate with the students' intention to pursue postgraduate study in medical imaging which were student attributes, being an academician, remuneration, finance, and social influences (p  0.05).

    CONCLUSION: Five out of seven factors tested were found to significantly influence students' decision to pursue postgraduate education in medical imaging. Effective strategies based on the influencing factors should be strategized to encourage more students to pursue postgraduate education in medical imaging.

    IMPLICATIONS FOR PRACTICE: Implementation of effective strategies based on the influencing factors will improve access to education among radiography students, ultimately enhancing future radiographers' capability and competency.

  6. Md Dom S, Abdul Razak HR, Ahmad Zaiki FW, Saat NH, Abd Manan K, Che Isa IN, et al.
    Quant Imaging Med Surg, 2013 Feb;3(1):49-53.
    PMID: 23483040 DOI: 10.3978/j.issn.2223-4292.2013.02.06
    The aim of this study was to investigate the changes in parathyroid hormone (PTH) level of rabbit foetal bodies exposed to ultrasound at different gestational stages. A total of 9 pregnant rabbits (Oryctolagus cuniculus) were insonated for 60 minutes at the middle of 1(st), 2(nd) and 3(rd) gestational stages for group A (n=14 newborns), group B (n=7 newborns) and group C (n=24 newborns) respectively. Seven pregnant rabbits with 41 newborns severed as negative control group. Blood samples were withdrawn from each newborn rabbits for Parathyroid Hormone-Intact (PTH-I) test. Results of the independent samples t-test implied statistically significant differences (P<0.05) between the control group and the 1(st) stage (P=0.001), the 2(nd) stage (P<0.001) and the 3(rd) stage group (P<0.001). This in-vivo study revealed diagnostic ultrasound heating has the potential of affecting foetal PTH level. This study observed significantly low PTH level for all the treated groups. A further study should be instituted to determine whether this finding in rabbit may also occur in human by means of clinical trials.
  7. Shaffiq Said Rahmat SM, Abdul Karim MK, Che Isa IN, Abd Rahman MA, Noor NM, Hoong NK
    Comput Biol Med, 2020 08;123:103840.
    PMID: 32658782 DOI: 10.1016/j.compbiomed.2020.103840
    BACKGROUND: Unoptimized protocols, including a miscentered position, might affect the outcome of diagnostic in CT examinations. In this study, we investigate the effects of miscentering position during CT head examination on the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR).

    METHOD: We simulate the CT head examination using a water phantom with a standard protocol (120 kVp/180 mAs) and a low dose protocol (100 kVp/142 mAs). The table height was adjusted to simulate miscentering by 5 cm from the isocenter, where the height was miscentered superiorly (MCS) at 109, 114, 119, and 124 cm, and miscentered inferiorly (MCI) at 99, 94, 89, and 84 cm. Seven circular regions of interest were used, with one drawn at the center, four at the peripheral area of the phantom, and two at the background area of the image.

    RESULTS: For the standard protocol, the mean CNR decreased uniformly as table height increased and significantly differed (p 

  8. Ravintaran T, Go KX, Che Isa IN, Mohd Norsuddin N, Sabarudin A, Mohamed Sharif N, et al.
    Heliyon, 2023 Jan;9(1):e12773.
    PMID: 36685374 DOI: 10.1016/j.heliyon.2022.e12773
    BACKGROUND: Lack of public understanding, perception and awareness of the biological effects of prenatal ultrasound has led to the non-medical use of ultrasound. An educational programme is required to enlighten pregnant women and the public regarding prenatal ultrasound safety.

    OBJECTIVE: To evaluate the effectiveness of educational modules (video and brochure) in improving knowledge, awareness and perception (KAP) among pregnant women regarding prenatal ultrasound safety.

    METHODS: This is a quasi-experimental study with a pre-and post-test design. This study recruited 51 pregnant women as respondents from the Obstetrics and Gynaecology clinic (O&G) of Hospital Canselor Tuanku Muhriz (HCTM). The first phase of the study was conducted by distributing a set of closed-ended questionnaires with multiple choice and Likert scale answers to assess the KAP of pregnant women regarding the safe use of prenatal ultrasound, followed by educational modules where the respondents were allocated into three groups (17 watched a video, 17 received brochure and 17 received combined media). After the intervention, the respondents' KAP were assessed using the same questionnaire.

    RESULTS: The Wilcoxon signed rank test showed that educational modules like video, brochure and combined media had a statistically significant increase in post-test scores over the pre-test scores (video: mean rank = 9.00, p  0.05). The Kruskal Wallis test indicated that educational video was more effective in improving the KAP of pregnant women than the brochure and combined media (mean rank = 34.62, p 