Displaying all 5 publications

Abstract:
Sort:
  1. Jamlos MA, Jamlos MF, Alias A, Karim MSA, Mustafa WA, Akkaraekthalin P
    Polymers (Basel), 2021 Sep 24;13(19).
    PMID: 34641072 DOI: 10.3390/polym13193254
    This paper investigates the use of a Magnetite Polydimethylsiloxane (PDMS) Graphene array sensor in ultra-wide band (UWB) spectrum for microwave imaging applications operated within 4.0-8.0 GHz. The proposed array microwave sensor comprises a Graphene array radiating patch, as well as ground and transmission lines with a substrate of Magnetite PDMS-Ferrite, which is fed by 50 Ω coaxial ports. The Magnetite PDMS substrate associated with low permittivity and low loss tangent realized bandwidth enhancement and the high conductivity of graphene, contributing to a high gain of the UWB array antenna. The combination of 30% (ferrite) and 70% (PDMS) as the sensor's substrate resulted in low permittivity as well as a low loss tangent of 2.6 and 0.01, respectively. The sensor radiated within the UWB band frequency of 2.2-11.2 (GHz) with great energy emitted in the range of 3.5-15.7 dB. Maximum energy of 15.7 dB with 90 × 45 (mm) in small size realized the integration of the sensor for a microwave detection system. The material components of sensor could be implemented for solar panel.
  2. Alias NA, Mustafa WA, Jamlos MA, Alkhayyat A, Rahman KSA, Q Malik R
    Oncol Res, 2021;29(5):365-376.
    PMID: 37305159 DOI: 10.32604/or.2022.025897
    Cervical cancer is a prevalent and deadly cancer that affects women all over the world. It affects about 0.5 million women anually and results in over 0.3 million fatalities. Diagnosis of this cancer was previously done manually, which could result in false positives or negatives. The researchers are still contemplating how to detect cervical cancer automatically and how to evaluate Pap smear images. Hence, this paper has reviewed several detection methods from the previous researches that has been done before. This paper reviews pre-processing, detection method framework for nucleus detection, and analysis performance of the method selected. There are four methods based on a reviewed technique from previous studies that have been running through the experimental procedure using Matlab, and the dataset used is established Herlev Dataset. The results show that the highest performance assessment metric values obtain from Method 1: Thresholding and Trace region boundaries in a binary image with the values of precision 1.0, sensitivity 98.77%, specificity 98.76%, accuracy 98.77% and PSNR 25.74% for a single type of cell. Meanwhile, the average values of precision were 0.99, sensitivity 90.71%, specificity 96.55%, accuracy 92.91% and PSNR 16.22%. The experimental results are then compared to the existing methods from previous studies. They show that the improvement method is able to detect the nucleus of the cell with higher performance assessment values. On the other hand, the majority of current approaches can be used with either a single or a large number of cervical cancer smear images. This study might persuade other researchers to recognize the value of some of the existing detection techniques and offer a strong approach for developing and implementing new solutions.
  3. Alias NA, Mustafa WA, Jamlos MA, Alquran H, Hanafi HF, Ismail S, et al.
    Diagnostics (Basel), 2022 Nov 22;12(12).
    PMID: 36552907 DOI: 10.3390/diagnostics12122900
    Cervical cancer is regularly diagnosed in women all over the world. This cancer is the seventh most frequent cancer globally and the fourth most prevalent cancer among women. Automated and higher accuracy of cervical cancer classification methods are needed for the early diagnosis of cancer. In addition, this study has proved that routine Pap smears could enhance clinical outcomes by facilitating the early diagnosis of cervical cancer. Liquid-based cytology (LBC)/Pap smears for advanced cervical screening is a highly effective precancerous cell detection technology based on cell image analysis, where cells are classed as normal or abnormal. Computer-aided systems in medical imaging have benefited greatly from extraordinary developments in artificial intelligence (AI) technology. However, resource and computational cost constraints prevent the widespread use of AI-based automation-assisted cervical cancer screening systems. Hence, this paper reviewed the related studies that have been done by previous researchers related to the automation of cervical cancer classification based on machine learning. The objective of this study is to systematically review and analyses the current research on the classification of the cervical using machine learning. The literature that has been reviewed is indexed by Scopus and Web of Science. As a result, for the published paper access until October 2022, this study assessed past approaches for cervical cell classification based on machine learning applications.
  4. Zahir SADM, Jamlos MF, Omar AF, Jamlos MA, Mamat R, Muncan J, et al.
    PMID: 37666099 DOI: 10.1016/j.saa.2023.123273
    Experiments demonstrated that visible and near-infrared (Vis-NIR) spectroscopy is a highly reliable tool for determining the nutritional status of plants. Although numerous studies on various kinds of plants have been conducted, there are only a few summaries of the research findings regarding the absorbance bands in the visible and near-infrared region and how they relate to the nutritional status of plants. This article will discuss the application of Vis-NIR spectroscopy for monitoring the nutrient conditions of plants, with a particular emphasis on three major components required by plants, namely nitrogen (N), phosphorus (P), and potassium (K), or NPK. Each section discussed different topics, for instance, the essential nutrients needed by plants, the application of Vis-NIR spectroscopy in nutrient status analysis, chemometrics tools, and absorbance bands related to the nutrient status, respectively. Deduction made concluded that factors affecting the plant's structure are contributed by several circumstances like the age of leaves, concentration of pigments, and water content. These factors are intertwined, strongly correlated, and can be observed in the visible and near-infrared regions. While the visible region is commonly utilised for nutritional analysis in plants, the literature review performed in this paper shows that the near-infrared region as well contains valuable information about the plant's nutritional status. A few wavelengths related to the direct estimation of nutrients in this review explained that information on nutrients can be linked with chlorophyll and water absorption bands such that N and P are the components of chlorophyll and protein; on the other hand, K exists in the form of cationic carbohydrates which are sensitive to water region.
  5. Jamlos MA, Jamlos MF, Mustafa WA, Othman NA, Rohani MNKH, Saidi SA, et al.
    Nanomaterials (Basel), 2022 Dec 21;13(1).
    PMID: 36615938 DOI: 10.3390/nano13010027
    A low cost, with high performance, reduced graphene oxide (RGO) Ultra-wide Band (UWB) array sensor is presented to be applied with a technique of confocal radar-based microwave imaging to recognize a tumor in a human brain. RGO is used to form its patches on a Taconic substrate. The sensor functioned in a range of 1.2 to 10.8 GHz under UWB frequency. The sensor demonstrates high gain of 5.2 to 14.5 dB, with the small size of 90 mm × 45 mm2, which can be easily integrated into microwave imaging systems and allow the best functionality. Moreover, the novel UWB RGO array sensor is established as a detector with a phantom of the human head. The layers' structure represents liquid-imitating tissues that consist of skin, fat, skull, and brain. The sensor will scan nine different points to cover the whole one-sided head phantom to obtain equally distributed reflected signals under two different situations, namely the existence and absence of the tumor. In order to accurately detect the tumor by producing sharper and clearer microwave image, the Matrix Laboratory software is used to improve the microwave imaging algorithm (delay and sum) including summing the imaging algorithm and recording the scattering parameters. The existence of a tumor will produce images with an error that is lower than 2 cm.