In this study, concentrations of Cd, Ni, Pb, and Cr were determined in tobacco, tobacco smoke-condensate, and cigarette ash for selected brands used in Pakistan. Smoking apparatus was designed for metal extraction from cigarette smoke. Samples were digested through microwave digester and then analyzed by flame atomic absorption spectrophotometer (FAAS). Higher concentration of Ni was detected in imported brands than the counterparts in the local brands. Pb levels were however higher in local brands while significant concentration of Cd was observed in both brands. For Cr, the level in tobacco of local brands was higher than their emitted smoke, whereas imported brands showed higher level in smoke than in tobacco. The cigarette ash retained 65 to 75% of the metal and about 25 to 30% went into the body. While this study revealed the serious requirement to standardize the manufacturing of tobacco products, more importantly is the urgent need for stronger enforcements to put in place to alert the general population about the hazardous effects of cigarettes and the health risks associated with these toxic metals.
Ultraviolet-C sourced LED (UVC-LED) has been widely used for disinfection purposes due to its germicidal spectrum. In this study, the efficiencies of UVC-LED for Pseudomonas aeruginosa (P. aeruginosa) and Staphylococcus aureus (S. aureus) disinfections were investigated at three exposure distances (1, 1.5, and 2 cm) and two exposure times (30 and 60 s). The respective bacterial inhibition zones were measured, followed by a morphological analysis under SEM. The viabilities of human skin fibroblast cells were further evaluated under the treatment of UVC-LED with the adoption of aforesaid exposure parameters. The inhibition zones were increased with the increment of exposure distances and times. The highest records of 5.40 ± 0.10 cm P. aeruginosa inhibition and 5.43 ± 0.11 cm S. aureus inhibition were observed at the UVC-LED distance of 2 cm and 60-s exposure. Bacterial physical damage with debris formation and reduction in size were visualized following the UVC-LED exposures. The cell viability percentages were in a range of 75.20-99.00% and 82-100.00% for the 30- and 60-s exposures, respectively. Thus, UVC-LED with 275-nm wavelength is capable in providing bacterial disinfection while maintaining accountable cell viability which is suitable to be adopted in wound treatment. Bacterial disinfection and human skin fibroblast cell assessment using UVC-LED.
Recent widespread connections of renewable energy resource (RESs) in place of fossil fuel supplies and the adoption of electrical vehicles in place of gasoline-powered vehicles have given birth to a number of new concerns. The control architecture of linked power networks now faces an increasingly pressing challenge: tie-line power fluctuations and reducing frequency deviations. Because of their nature and dependence on external circumstances, RESs are analogous to continually fluctuating power generators. Using a fractional order-based frequency regulator, this work presents a new method for improving the frequency regulation in a two-area interconnected power system. In order to deal with the frequency regulation difficulties of the hybrid system integrated with RES, the suggested controller utilizes the modified form of fractional order proportional integral derivative (FOPID) controller known as FOI-PDN controller. The new proposed controllers are designed using the white shark optimizer (WSO), a current powerful bioinspired meta heuristic algorithm which has been motivated by the learning abilities of white sharks when actively hunting in the environment. The suggested FOI-PDN controller's performance was compared to that of various control methodologies such as FOPID, and PID. Furthermore, the WSO findings are compared to those of other techniques such as the salp swarm algorithm, sine cosine algorithm and fitness dependent optimizer. The recommended controller and design approach have been tested and validated at different loading conditions and different circumstances, as well as their robustness against system parameter suspicions. The simulation outcomes demonstrate that the WSO-based tuned FOI-PDN controller successfully reduces peak overshoot by 73.33%, 91.03%, and 77.21% for region-2, region-1, and link power variation respectively, and delivers minimum undershoot of 89.12%, 83.11%, and 78.10% for both regions and tie-line. The obtained findings demonstrate the new proposed controller's stable function and frequency controlling performance with optimal controller parameters and without the requirement for a sophisticated design process.
In this paper, we propose two different control strategies for the position control of the ball of the ball and beam system (BBS). The first control strategy uses the proportional integral derivative-second derivative with a proportional integrator PIDD2-PI. The second control strategy uses the tilt integral derivative with filter (TID-F). The designed controllers employ two distinct metaheuristic computation techniques: grey wolf optimization (GWO) and whale optimization algorithm (WOA) for the parameter tuning. We evaluated the dynamic and steady-state performance of the proposed control strategies using four performance indices. In addition, to analyze the robustness of proposed control strategies, a comprehensive comparison has been performed with a variety of controllers, including tilt integral-derivative (TID), fractional order proportional integral derivative (FOPID), integral-proportional derivative (I-PD), proportional integral-derivative (PI-D), and proportional integral proportional derivative (PI-PD). By comparing different test cases, including the variation in the parameters of the BBS with disturbance, we examine step response, set point tracking, disturbance rejection analysis, and robustness of proposed control strategies. The comprehensive comparison of results shows that WOA-PIDD2-PI-ISE and GWO-TID-F- ISE perform superior. Moreover, the proposed control strategies yield oscillation-free, stable, and quick response, which confirms the robustness of the proposed control strategies to the disturbance, parameter variation of BBS, and tracking performance. The practical implementation of the proposed controllers can be in the field of under actuated mechanical systems (UMS), robotics and industrial automation. The proposed control strategies are successfully tested in MATLAB simulation.