Displaying all 6 publications

Abstract:
Sort:
  1. Nur Fitrah Che Nan, Norhazlin Zainuddin, Mansor Ahmad
    MyJurnal
    Carboxymethylcellulose (CMC) is a water-soluble polymer, which is widely used in various
    fields such as food additives, textiles, pharmaceuticals and cosmetics. In this study, hydrogel
    was prepared from CMC by using calcium chloride as a crosslinking agent. Optimization
    of the reaction was done through investigation of four different parameters which had
    different percentage of CMC (w/v), percentage of calcium chloride (w/v), reaction time and
    temperature. The gel content and swelling properties of the CMC hydrogel were studied.
    The highest gel content was 85.33% at 7% of CMC (w/v) with 2% of calcium chloride (w/v)
    in 24 hours reaction time at room temperature. The gel content increased with the increasing
    concentration of CMC and CaCl2. This was due to the higher number of functional groups
    of COO- that were available in more concentrated CMC which could crosslink with CaCl2
    to give higher gel content. Increasing the percentage of CaCl2 will increase the electrostatic
    attraction between anionic charges of polymer chains and multivalent cation (Ca2+) that
    leads to increase in ionic crosslinking of CMC. The swelling properties of CMC hydrogel
    showed that the optimum degree of swelling was 45.33 (g/g). The swelling capacity of the
    hydrogel in water decreased with the increase of the gel content of CMC hydrogel. This
    could be due to the increase in the degree of crosslinking of the CMC hydrogel.
  2. Salih, A.M., Wan Md. Zin Wan Yunus, Khairul Zaman Mohd Dahlan, Mohd Hilmi Mahmood, Mansor Ahmad
    MyJurnal
    Synthesis of palm oil based-urethane acrylate (POBUA) resins was carried out by acrylation of epoxidizedpalm oil (EPOP) using acrylic acid in the presence of a catalyst and followed by isocyanation to obtainthe POBUA. Using the monomer as a diluent in the formulation, 4% of photoinitiator and incorporationof organoclay (1-5% wt), nanocomposites were obtained upon UV irradiation. The X-ray DiffractoryXRD study revealed that the nanocomposites obtained were of the exfoliation type. The presence ofthe clay improved the hardness and did not affect the thermal stability. Similarly, it increased the glasstransition temperature Tg but reduced the modulus as the clay content was increased. The improvementof the tensile strength was only obtained when the clay concentration was 5 phr.
  3. Mansor AF, Azmi AI, Zain MZM, Jamaluddin R
    Heliyon, 2020 Aug;6(8):e04812.
    PMID: 32913911 DOI: 10.1016/j.heliyon.2020.e04812
    Nickel-titanium shape memory alloy (NiTi) has a unique capacity to restore its initial shape after deformation, which is highly applicable to orthopaedic implantations, especially for the minimization of invasive surgeries. The high nickel content of this alloy can lead to unfavourable effects on the human body upon dissolution; thus, a reliable barrier of coatings on the NiTi surface is required to alleviate the nickel migration and increase its biocompatibility. In this paper, analyses of a titanium oxide layer development on NiTi surface using electrical discharge coating (EDC) process is presented. The recast layer thickness, crater sizes, and surface roughness were characterized based on five parameters; polarity, discharge duration, pulse interval, peak current, and gap voltage. The results show that the discharge duration is the most significant parameter to influence all responses, followed by peak current. The surface characteristics of the EDC substrate is depending on the crater formations and is highly correlated with the discharge energy intensity. As a result, appropriate parametric conditions of the electrical discharge coating process can enhance the NiTi surface for future medical applications, without compromising the shape memory effect.
  4. Mansor AFM, Ibrahim I, Zainuddin AA, Voiculescu I, Nordin AN
    Med Biol Eng Comput, 2018 Jan;56(1):173-181.
    PMID: 29247387 DOI: 10.1007/s11517-017-1756-1
    Electrical cell-substrate impedance sensing (ECIS) is a powerful technique to monitor real-time cell behavior. In this study, an ECIS biosensor formed using two interdigitated electrode structures (IDEs) was used to monitor cell behavior and its response to toxicants. Three different sensors with varied electrode spacing were first modeled using COMSOL Multiphysics and then fabricated and tested. The silver/silver chloride IDEs were fabricated using a screen-printing technique and incorporated with polydimethylsiloxane (PDMS) cell culture wells. To study the effectiveness of the biosensor, A549 lung carcinoma cells were seeded in the culture wells together with collagen as an extracellular matrix (ECM) to promote cell attachment on electrodes. A549 cells were cultured in the chambers and impedance measurements were taken at 12-h intervals for 120 h. Cell index (CI) for both designs were calculated from the impedance measurement and plotted in comparison with the growth profile of the cells in T-flasks. To verify that the ECIS biosensor can also be used to study cell response to toxicants, the A549 cells were also treated with anti-cancer drug, paclitaxel, and its responses were monitored over 5 days. Both simulation and experimental results show better sensitivity for smaller spacing between electrodes. Graphical abstract The fabricated impedance biosensor used screen-printed silver/silver chloride IDEs. Simulation and experimental results show better sensitivity for smaller between electrodes.
  5. Damanhuri NS, Kumolosasi E, Omar MS, Razak AFA, Mansor AH
    Daru, 2021 Jun;29(1):13-22.
    PMID: 33405191 DOI: 10.1007/s40199-020-00377-2
    BACKGROUND: P-glycoprotein (P-gp) is an Adenosine triphosphate (ATP) dependent drug-efflux pump which is located abundantly in the stomach and protects the gut mucosa from xenobiotic.

    OBJECTIVE: The purpose of this study was to investigate the influence of P-gp modulation on the efficacy of treatment regimen.

    METHOD: P-gp modulation in rats was performed by using P-gp inducer (150 mg/kg rifampicin) and P-gp inhibitor (10 mg/kg cyclosporine A) for 14 days prior to be infected with Helicobacter pylori (H. pylori). The rats were further divided into groups, which were normal control, vehicle control, antibiotics and omeprazole, antibiotics only and omeprazole only for another 2 weeks of treatment. The ulcer formation and P-gp expression were determined by using macroscopic evaluation and western blot analysis, respectively.

    RESULTS: The highest P-gp expression was shown in the induced P-gp rats (2.00 ± 0.68) while the lowest P-gp expression was shown in the inhibited P-gp rats (0.45 ± 0.36) compared to the normal P-gp rats. In all groups, the rats which were infected with H. pylori, had a significant increase (p 

  6. Yunos MFAM, Manczak R, Guines C, Mansor AFM, Mak WC, Khan S, et al.
    Biosensors (Basel), 2021 Dec 03;11(12).
    PMID: 34940251 DOI: 10.3390/bios11120494
    Diabetes has become a major health problem in society. Invasive glucometers, although precise, only provide discrete measurements at specific times and are unsuitable for long-term monitoring due to the injuries caused on skin and the prohibitive cost of disposables. Remote, continuous, self-monitoring of blood sugar levels allows for active and better management of diabetics. In this work, we present a radio frequency (RF) sensor based on a stepped impedance resonator for remote blood glucose monitoring. When placed on top of a human hand, this RF interdigital sensor allows detection of variation in blood sugar levels by monitoring the changes in the dielectric constant of the material underneath. The designed stepped impedance resonator operates at 3.528 GHz with a Q factor of 1455. A microfluidic device structure that imitates the blood veins in the human hand was fabricated in PDMS to validate that the sensor can measure changes in glucose concentrations. To test the RF sensor, glucose solutions with concentrations ranging from 0 to 240 mg/dL were injected into the fluidic channels and placed underneath the RF sensor. The shifts in the resonance frequencies of the RF sensor were measured using a network analyzer via its S11 parameters. Based on the change in resonance frequencies, the sensitivity of the biosensor was found to be 264.2 kHz/mg·dL-1 and its LOD was calculated to be 29.89 mg/dL.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links