  1. Puteri Nor Khatijah Abd Hamid, Abdul Aziz Tajuddin, Mohd Fahmi Mohd Yusof, Rokiah Hashim
    MyJurnal
    The particleboards were fabricated using Rhizophora spp. wood particles with particles size less than 74 μm. The corn starch was used as a bio-adhesive in the fabrication of Rhizophora spp. particleboards. The corn starch bonded particleboards were fabricated at 5% and 10% corn starch based on dry mass of Rhizophora spp. wood particles. The measurement of mass attenuation coefficients of the particleboards were made at low and intermediate photon energies. The mass attenuation coefficient at low photon energy was measured using X-ray fluorescent (XRF) configuration based on attenuation of Kα1 X-ray energies between 16.59 and 25.26 keV given by niobium, molybdenum, palladium and tin metal plates. The calculated mass attenuation coefficients of samples were compared to the theoretical values mass attenuation coefficients of water calculated using the photon cross-section database (XCOM). The results showed that mass attenuation coefficients of 10% corn starch added Rhizophora spp. particleboards were in good agreement of water within 7.96 and 4.94% for 5% and 10% corn starch Rhizophora spp. Particleboards, respectively compared to 14.57 and 16.16% in binderless Rhizophora spp. particleboards and raw Rhizophora spp. wood, respectively.
  2. Mohd Fahmi Mohd Yusof, Nur Amirah Nabila Ramli, Mohd Fahrizuan Md Yusop, Reduan Abdullah
    MyJurnal
    This study evaluates the ImageJ software as dosimetric tools for analyzing the film dosimeter in high energy photons and electrons. The percentage depth dose of photons of 6 and 10 MV and electrons of 6 and 9 MeV were measured using the Gafchromic EBT2 film dosimeter. The films were scanned and analyzed using the Verisoft software and ImageJ. The beam profiles at nominal photon and electron beam parameters were also evaluated using the two methods. The PDD measured in ImageJ at high energy photons were in good agreement within 1% percentage of discrepancy at all depths in comparison to the Verisoft software. The PDD measured in ImageJ at high energy electrons also showed good agreement to Verisoft software within 8% percentage of discrepancy at all depths. The measured flatness of beam profiles at Dmax, R50, R80 and R90 in ImageJ were also in good agreement to Verisoft software with flatness value between 4 and 8%. The results indicated the suitability of ImageJ software as dosimetric tool for analyzing EBT2 film dosimeter at high energy photon and electrons.
  3. Mohd Fahmi Mohd Yusof, Puteri Nor Khatijah Abd Hamid, Abdul Aziz Tajuddin, Rokiah Hashim, Norriza Mohd Isa
    MyJurnal
    The mass attenuation coefficients of solid water phantoms, Perspex® phantoms and Rhizophora spp. particleboards were determined by using Compton scattering technique measured using Ludlum configuration. The gamma energy of 137Cs sealed source were measured at 30°, 45°, 60° and 75° angles providing scattered gamma energies between 337.72 and 564.09 keV. The mass attenuation coefficients of solid water and fabricated Rhizophora spp. particleboards were the nearest to XCOM values of water with average percentage of discrepancies of 6.8% and 5.9%, respectively. The results indicated similar attenuation properties of solid water and fabricated Rhizophora spp. particleboards and the suitability of the Ludlum configuration to determine the mass attenuation coefficient of materials using Compton scatter technique.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links