Displaying all 7 publications

Abstract:
Sort:
  1. Hayati F, Mohd Azman ZA, Nasuruddin DN, Mazlan L, Zakaria AD, Sagap I
    Asian Pac J Cancer Prev, 2017 07 27;18(7):1821-1825.
    PMID: 28749112
    Background: Anastomotic leaks in colorectal surgery results in a high morbidity and mortality rate. Serum procalcitonin levels is known as a sensitive and specific marker of sepsis and could be use as a marker for early detection of a leak allowing early intervention. It may help a clinician decide to perform a CT scan even earlier especially when the diagnosis of a leak is uncertain. The aim of this study is to determine whether serum procalcitonin is a good predictor of anastomotic leak in colorectal surgery. Methodology: Between July 2014 until October 2015, 70 patients undergoing colorectal surgery were prospectively analyzed in a single-center tertiary teaching hospital. Demographic and surgical data were obtained. Serum procalcitonin was taken before surgery and at day 3 (72 hours) postoperatively. During the postoperative period, the patients were observed in the ward for features of anastomotic leak and if present, it was managed accordingly. The primary outcome was to prospectively determine an association between serum procalcitonin levels and an anastomotic leak in patients who underwent colorectal surgery with a primary anastomosis. Result: The rate of anastomotic leak was 4.5% (3 patients) with a mortality rate of 4.3% (3 patients). A rise in serum procalcitonin was statistically significant among patients with anastomotic leak. The optimal procalcitonin cut-off level at postoperative day 3 was 5.27 ng/mL, resulting in 100% sensitivity, 85% specificity, 23% positive predictive value and 100% negative predictive value. Nevertheless, none of the variables showed statistical significance with an anastomotic leak. Conclusion: Procalcitonin is a reliable biochemical marker to help diagnose anastomotic leak in colorectal surgery. Our study has shown that a level of 5 times beyond normal is statistically significant and a value of more than 5.27 ng/mL is confirmatory of a leak.
  2. Zakariah NA, Bajuri MY, Hassan R, Ismail Z, Md Mansor M, Othman H, et al.
    Malays J Pathol, 2020 Apr;42(1):77-84.
    PMID: 32342934
    INTRODUCTION: Procalcitonin (PCT) has recently emerged as a marker for diagnosing infection. This study aimed to compare the performance of PCT and other infection markers in diagnosing infected diabetic foot ulcer (IDFU).

    MATERIALS AND METHODS: A total of 128 diabetic patients with foot ulcers were recruited and divided into two groups, consisting of 73 patients in the IDFU group and 55 in the non-infected diabetic foot ulcer (NIDFU). The severity of infection in IDFU patients was graded based on the Infectious Disease Society of America-International Working Group on the Diabetic Foot classification. Blood samples from all the patients were collected for measurement of PCT, high sensitivity C-reactive protein (hs-CRP) and white cell count (WBC). The area under the receiver operating curves (AUC) were then constructed and analysed.

    RESULTS: PCT, hs-CRP and WBC levels were significantly higher in the IDFU group compared to NIDFU with hs-CRP demonstrated the highest AUC (0.91; p <0.001) followed by PCT (0.814; p < 0.001) and lastly WBC (0.775; p < 0.001). The best cut off value, sensitivity and specificity for the presence of infection in diabetic foot, were 3.47 mg/dL, 80% and 89% for hs-CRP, 0.11 ng/ml, 70% and 87% for PCT and 11.8x109/L, 60% and 90% for WBC. All the infection markers showed significant positive correlations with infection severity of DFU.

    CONCLUSION: This study showed that hs-CRP is a more sensitive marker for diagnosing IDFU. Although PCT is useful in differentiating IDFU from NIDFU, the use of PCT is not necessary as it adds little value to the current practice.

  3. Sthaneshwar P, Thambiah SC, Mat Salleh MJ, Nasuruddin DN, Ahmad Zabidi NF, Jelani AM, et al.
    Malays J Pathol, 2021 Aug;43(2):281-290.
    PMID: 34448792
    INTRODUCTION: Serum protein electrophoresis (SPE) is a well-established laboratory technique. However, reporting of results varies considerably between laboratories. The variation in reporting can cause confusion to the clinician with a potential of adversely impacting patient care. The purpose of the survey was to find out the variation in reporting and to prepare recommendations to the Malaysian laboratories based on the survey to reduce both the variation in reporting between laboratories and the risk of misinterpretation of reports.

    MATERIALS AND METHODS: To determine the extent of variation in reporting of protein electrophoresis results questionnaires were distributed to the pathologists of various laboratories in Malaysia regarding the method, quantification of paraprotein concentrations and immunoglobulin assays, and information regarding current laboratory electrophoresis practices.

    RESULTS: Variation was found in the following reporting practices: (a) screening protocol; (b) reporting of serum albumin; (c) numerical reporting of protein fractions and paraprotein; (d) co-migration of a paraprotein with a normal serum protein; (e) reporting of multiple paraprotein bands (f) appearance of small abnormal band and oligoclonal bands and (g) communication about of interferences.

    CONCLUSION: The pathologists of the country made recommendations on the reporting of protein electrophoresis. Harmonised reporting will reduce inconsistency, variation in reporting, improve the quality of the report and most importantly improve patient care.

  4. Tan TL, Ahmad NS, Nasuruddin DN, Ithnin A, Tajul Arifin K, Zaini IZ, et al.
    PLoS One, 2016;11(3):e0152065.
    PMID: 27003588 DOI: 10.1371/journal.pone.0152065
    INTRODUCTION: Early diagnosis of sepsis and bacterial infection is imperative as treatment relies on early antibiotic administration. There is a need to develop new biomarkers to detect patients with sepsis and bacterial infection as early as possible, thereby enabling prompt antibiotic treatment and improving the survival rate.

    METHODS: Fifty-one adult patients with suspected bacterial sepsis on admission to the Emergency Department (ED) of a teaching hospital were included into the study. All relevant cultures and serology tests were performed. Serum levels for Group II Secretory Phospholipase A2 (sPLA2-IIA) and CD64 were subsequently analyzed.

    RESULTS AND DISCUSSION: Sepsis was confirmed in 42 patients from a total of 51 recruited subjects. Twenty-one patients had culture-confirmed bacterial infections. Both biomarkers were shown to be good in distinguishing sepsis from non-sepsis groups. CD64 and sPLA2-IIA also demonstrated a strong correlation with early sepsis diagnosis in adults. The area under the curve (AUC) of both Receiver Operating Characteristic curves showed that sPLA2-IIA was better than CD64 (AUC = 0.93, 95% confidence interval (CI) = 0.83-0.97 and AUC = 0.88, 95% CI = 0.82-0.99, respectively). The optimum cutoff value was 2.13μg/l for sPLA2-IIA (sensitivity = 91%, specificity = 78%) and 45 antigen bound cell (abc) for CD64 (sensitivity = 81%, specificity = 89%). In diagnosing bacterial infections, sPLA2-IIA showed superiority over CD64 (AUC = 0.97, 95% CI = 0.85-0.96, and AUC = 0.95, 95% CI = 0.93-1.00, respectively). The optimum cutoff value for bacterial infection was 5.63μg/l for sPLA2-IIA (sensitivity = 94%, specificity = 94%) and 46abc for CD64 (sensitivity = 94%, specificity = 83%).

    CONCLUSIONS: sPLA2-IIA showed superior performance in sepsis and bacterial infection diagnosis compared to CD64. sPLA2-IIA appears to be an excellent biomarker for sepsis screening and for diagnosing bacterial infections, whereas CD64 could be used for screening bacterial infections. Both biomarkers either alone or in combination with other markers may assist in decision making for early antimicrobial administration. We recommend incorporating sPLA2-IIA and CD64 into the diagnostic algorithm of sepsis in ED.

  5. Nyunt WWT, Abdul Jalil D, Zakariah NA, Abdul Karim N, Mohd Idris MR, Nasuruddin DN, et al.
    Malays J Pathol, 2020 Apr;42(1):143-150.
    PMID: 32342945
    INTRODUCTION: Plasma cell leukaemia (PCL) is a rare variant of multiple myeloma. We report a case of PCL to demonstrate the clonal evolution, resulting in disease relapse after achieving complete remission, and its aggressive nature of the disease, leading to poor clinical outcome.

    CASE REPORT: A 69-year-old man presented with a three-day-history of worsening generalized body weakness, poor oral intake, nausea, significant loss of weight and lower back pain. He was diagnosed as primary PCL, based on hypercalcaemia, renal insufficiency, anaemia, thrombocytopenia, lytic bone lesions, 24% abnormal plasma cells in peripheral blood, immunophenotype of clonal plasma cells which were positive for CD38, CD138 and CD56 markers with kappa light chain restriction, 49% abnormal plasma cells in bone marrow, monoclonal paraprotein (IgG kappa) in serum and urine, and positive IGH rearrangement (Fluorescence in-situ hybridisation, FISH). He achieved complete remission after four cycles of Bortezomib-based therapy. There was a plan for high-dose therapy plus autologous haematopoietic cell transplantation. A month later, the disease relapsed, as evidenced by 94% abnormal plasma cells in his bone marrow aspirate, complex karyotype and abnormal FISH results. He passed away a few days later, from severe septicaemia. Time-to-progression of disease was 1 month and overall survival was 5 months.

    DISCUSSION: This case report illustrates the clonal evolution and aggressive nature of primary PCL with older age at presentation, leading to a shorter duration of remission and overall survival.

  6. Tan TL, Kang CW, Ooi KS, Tan ST, Ahmad NS, Nasuruddin DN, et al.
    Sci Rep, 2021 05 31;11(1):11369.
    PMID: 34059757 DOI: 10.1038/s41598-021-90894-0
    Early bacterial infection (BI) identification in resource-limiting Emergency Departments (ED) is challenging, especially in low- and middle-income counties (LMIC). Misdiagnosis predisposes to antibiotic overuse and propagates antimicrobial resistance. This study evaluates new emerging biomarkers, secretory phospholipase A2 group IIA (sPLA2-IIA) and compares with other biomarkers on their performance characteristic of BI detection in Malaysia, an LMIC. A prospective cohort study was conducted involving 151 consecutive patients admitted to the ED. A single measurement was taken upon patient arrival in ED and was analysed for serum levels of sPLA2-IIA, high-sensitive C-reactive protein (CRP), procalcitonin (PCT), neutrophil percentage (N%), and lactate. All biomarkers' performance was compared for the outcomes using area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity. The performance of sPLA2-IIA (AUROC 0.93 [95% CI: 0.89-0.97]; Sn 80% [95% CI: 72-87]; Sp 94% [95% CI: 81-89]) was the highest among all. It was comparable with high-sensitive CRP (AUROC 0.93 [95% CI: 0.88-0.97]; Sn 75% [95% CI: 66-83]; Sp 91 [95% CI: 77-98]) but had a higher Sn and Sp. The sPLA2-IIA was also found superior to N%, PCT, and lactate. This finding suggested sPLA2-IIA was recommended biomarkers for BI detection in LMIC.
  7. Nik Mansor NN, Leong TT, Safitri E, Futra D, Ahmad NS, Nasuruddin DN, et al.
    Sensors (Basel), 2018 Feb 26;18(3).
    PMID: 29495352 DOI: 10.3390/s18030686
    A tri-enzyme system consisting of choline kinase/choline oxidase/horseradish peroxidase was used in the rapid and specific determination of the biomarker for bacterial sepsis infection, secretory phospholipase Group 2-IIA (sPLA2-IIA). These enzymes were individually immobilized onto the acrylic microspheres via succinimide groups for the preparation of an electrochemical biosensor. The reaction of sPLA2-IIA with its substrate initiated a cascading enzymatic reaction in the tri-enzyme system that led to the final production of hydrogen peroxide, which presence was indicated by the redox characteristics of potassium ferricyanide, K₃Fe(CN)₆. An amperometric biosensor based on enzyme conjugated acrylic microspheres and gold nanoparticles composite coated onto a carbon-paste screen printed electrode (SPE) was fabricated and the current measurement was performed at a low potential of 0.20 V. This enzymatic biosensor gave a linear range 0.01-100 ng/mL (R² = 0.98304) with a detection limit recorded at 5 × 10-3 ng/mL towards sPLA2-IIA. Moreover, the biosensor showed good reproducibility (relative standard deviation (RSD) of 3.04% (n = 5). The biosensor response was reliable up to 25 days of storage at 4 °C. Analysis of human serum samples for sPLA2-IIA indicated that the biosensor has potential for rapid bacterial sepsis diagnosis in hospital emergency department.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links