Displaying all 9 publications

Abstract:
Sort:
  1. Chooi YS, Penafort R
    Med J Malaysia, 2004 Dec;59(5):674-7.
    PMID: 15889572
    It has been at least a decade since the introduction of extra-corporeal shock-wave treatment (ESWT) for the treatment of non-unions. Despite conflicting opinions in the literature, it is recently experiencing a revival. This paper reports our experience with Ossa Tron, which produces shock-waves electro-hydraulically, on 5 patients. The two successful cases experienced remarkable results of union at an average of 22 weeks after ESWT. The remaining three had disappointing results. A description of the study and a note on the essential issues are presented.
  2. Foead A, Penafort R, Saw A, Sengupta S
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):76-82.
    PMID: 15237126
    To conduct a prospective randomised controlled study to compare the stability and risk of nerve injury between fractures treated by medial-lateral pin fixation and those treated by 2-lateral pin fixation.
  3. Kwan MK, Penafort R, Saw A
    Med J Malaysia, 2004 Dec;59 Suppl F:39-41.
    PMID: 15941159
    Joint stiffness is one of the complications of limb procedure. It developes as a result of failure of knee flexors to lengthen in tandem with the bone, especially when there is inadequate physical therapy to provide active and passive mobilization of the affected joint. We are reporting four patients who developed fixed flexion contracture of their knees during bone lengthening procedure for the tibia with Ilizarov external fixator. Three of them were treated for congenital pseudoarthrosis and one was for fibular hemimelia. None of them were able to visit the physiotherapist even on a weekly basis. A splint was constructed from components of Ilizarov external fixator and applied on to the existing frame to passively extend the affected knee. Patients and their family members were taught to perform this exercise regularly and eventually near complete correction were achieved. With this result, we would like to recommend the use of this "Passive Knee Extension Splint" to avoid knee flexion Contracture during limb lengthening procedures with Ilizarov external fixators.
  4. Shamsuddin SA, Penafort R, Sharaf I
    Med J Malaysia, 2001 Dec;56 Suppl D:38-44.
    PMID: 14569765 MyJurnal
    A retrospective study was done on 56 patients treated with percutaneous pinning of displaced supracondylar fractures of the humerus in the Paediatrics Institute of Hospital Kuala Lumpur between November 1999 and October 2000, to ascertain whether there is any significance clinically in the stability of a crossed pinning medial compared with lateral pinning method. There was equal number of patients in each group (28 patients). The radiographs were evaluated for change in Baumann's angle and Lateral Humero-capitellar angle from immediate post-op until the last follow-up. The changes in the angles did not reveal any statistically significant difference in the ability to maintain reduction of the fractures. There were 3 instances of iatrogenic ulnar nerve injury in the crossed pinning group; the lateral pinning group had 1 case each of anterior interosseous nerve and radial nerve injury post operatively. No vascular injury was noted. Two cases of superficial pin tract infection were present in each group. The lateral percutaneous pinning technique of displaced supracondylar fractures of the humerus therefore offers a viable alternative to the crossed pinning group as it offers the same stability without the incipient risk of iatrogenic ulnar nerve injury.
  5. Saw A, Chan CK, Penafort R, Sengupta S
    Med J Malaysia, 2006 Feb;61 Suppl A:62-5.
    PMID: 17042233
    Patients treated with external fixation for limb reconsturciton or fracture stabilization equire regular and prolongedperiod of pin-tract care involving frequent visits to clinic and dressing traditionally carried out by trained nurses or medical assistants. A simple method of do-it-yourself dressing was introduced in our institution and this study was undertaken to evaluate the effectiveness of the protocol. Sixty patients (40 trauma-related problems and 20 congenital or developmental disorders) were enrolled into the study. Following application of external fixation, the patients and/or their caretakers were taught on how to do pin-site dressing using normal saline or drinking water as cleansing solution on daily basis. Patients were discharged on the second or third post-operative day and were followed-up every two weeks for an average 182 days (range 66 to 379 days) with special attention on identifying pin-tract infection. A simple grading system for pin-tract infections was proposed. Of 40 patients with trauma-related problems. 65% were post-traumatic infections. There were 788 metal-skin interfaces (239 half-pin fixations and 549 tensioned wire fixations. A total 143 metal-skin interface infections (18.1%) involving half-pin sites (41.3%) and tensioned wire sites (58.7%) was noted. Majority were grade I infections (79.7%), 18.8% grade II and only 1.4% grade III. Most infections (81%)were caused by Staphylococcus aureus. Grade I infections were successfully treated with frequent dressing, grade II by adjunctive oral antibiotic but grade III infections required removal of fixator. All eventually healed. Do yourself non-sterile dressing of metal-skin interfaces is a cost-effective method of pin-site care with a low infection rate. The infections were sucessfully treated using guidelines according to the proposed classification of pin-tract infections.
  6. Kwan MK, Ng ES, Penafort R, Saw A, Sengupta S
    Med J Malaysia, 2005 Jul;60 Suppl C:66-71.
    PMID: 16381287 MyJurnal
    Bone defect following en bloc resection of primary bone tumor around the knee can be reconstructed by allograft or prothesis or combination of both. Resection-arthrodesis is an alternative option for young vigorous patients facing circumstances of financial constrain or limited supply of allograft. This study was undertaken to determine the outcome and complications associated with resection-arthrodesis of 22 primary bone tumors (13 giant cell tumors and 9 osteosarcomas) around the knee treated between 1990 and 2003 at the University Malaya Medical Center. The mean follow-up was 6 years (range 1-13 years). hree patients with osteosarcoma died of lung metastasis, 3 required above knee amputation and 2 defaulted follow-up. Local complications of the procedure include infection in 8 cases (36.4%), non-union 7 (31.8%) and mal-union. Of 14 patients who returned for final evaluation, 79.8% had satisfactory outcomes according to the Musculoskeletal Tumor Society grading system. In conclusion, resection-arthrodesis of the knee is a viable treatment option for selected patients with primary bone tumor around the knee, and good functional outcome can be expected in the presence of short-term local complications.
  7. Mohamed-Zain NA, Jamil K, Penafort R, Singh A, Ibrahim S, Abdul-Rashid AH
    Malays Orthop J, 2021 Jul;15(2):122-128.
    PMID: 34429832 DOI: 10.5704/MOJ.2107.018
    Introduction: To compare the anxiety levels demonstrated by children during cast removal procedure between oscillating saw vs cast shear methods.

    Material and methods: A randomised prospective study of 102 children (mean age 8.3 ± 3.5 years) with fractures involving upper or lower limbs. Children undergoing removal of cast were divided into 2 groups; either by an oscillating saw or a cast cutting shear. The level of anxiety was assessed by recording the heart rate with a portable fingertip pulse oximeter before, during and after removal of the cast. Objective assessment was performed by documenting the fear level on Children's Fear Scale (CFS).

    Results: There was a significant increase in the heart rate of children during cast removal while using the oscillating saw compared to cast shear (p<0.05). The noise level produced by the saw exceeded 80 dB (mean 103.3 dB). The fear level was significantly lower in the cast shear group (p<0.05).

    Conclusion: The noise produced by the oscillating saw was associated with an increased anxiety level in children undergoing cast removal. Cast shear is a simple and inexpensive instrument that can be used for cast removal in overly anxious children.

  8. Yong CK, Tan CN, Penafort R, Singh DA, Varaprasad MV
    Malays Orthop J, 2009;3(1):13-18.
    MyJurnal
    Dynamic hip screw (DHS) fixation is considered standard treatment for most intertrochanteric fractures. However, excessive sliding at the fracture site and medialisation of femoral shaft may lead in fixation failure. In contrast, fixed-angled 95° condylar blade plate (CBP) has no effective dynamic capacity and causes little bone loss compared to DHS. We compared the outcome of 57consecutive unstable intertrochanteric fragility fractures treated with these two fixation methods. CBP instrumentation is more difficult requiring longer incision, operating time and higher surgeon-reported operative difficulty. The six month post-operative mortality rate is 16%. Post-operative Harris hip scores were comparable between the two methods. Limb length shortening more than 20 mm was 6-fold more common with DHS. In elderly patients with unstable intertrochanteric fragility fractures, fixed angled condylar blade plate appears to be a better choice than dynamic hip screws for preventing fixation failures.
  9. Selvaratnam L, Abd Rahim S, Kamarul T, Chan KY, Sureshan S, Penafort R, et al.
    Med J Malaysia, 2005 Jul;60 Suppl C:49-52.
    PMID: 16381284
    In view of poor regeneration potential of the articular cartilage, in-vitro engineering of cartilage tissue offers a promising option for progressive joint disease. This study aims to develop a biologically engineered articular cartilage for autologous transplantation. The initial work involved determination of chondrocyte yield and viability, and morphological analysis. Cartilage was harvested from the knee, hip and shoulder joints of adult New Zealand white rabbits and chondrocytes were isolated by enzymatic digestion of the extra-cellular matrix before serial cultivation in DMEM/Ham's F12 media as monolayer cultures. No differences were noted in cell yield. Although chondrocytes viability was optimal (>93%) following harvest from native cartilage, their viability tended to be lowered on passaging. Chondrocytes aggregated in isogenous colonies comprising ovoid cells with intimate intracellular contacts and readily exhibited Safranin-O positive matrix; features typically associated with articular cartilage in-vivo. However, chondrocytes also existed concurrently in scattered bipolar/multipolar forms lacking Safranin-O expression. Therefore, early data demonstrated successful serial culture of adult chondrocytes with differentiated morphology seen in established chondrocyte colonies synthesizing matrix proteoglycans.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links