Displaying all 3 publications

Abstract:
Sort:
  1. Abdullah N, Mohd Said S, Marlina A, Roslan MF, Azil A, Nordin AR
    ScientificWorldJournal, 2015;2015:860537.
    PMID: 25879076 DOI: 10.1155/2015/860537
    A dimeric iron(II) complex, trans-[Fe2(CH3COO)4(L1)2] (1), and a trinuclear iron(II) complex, [Fe3(CH3COO)4(H2O)4(L2)] (2), were studied as potential dye-sensitised solar cell materials. The structures of both complexes were deduced by a combination of instrumental analyses and molecular modelling. Variable-temperature magnetic susceptibility data suggested that 1 was made up of 56.8% high-spin (HS) and 43.2% low-spin (LS) Fe(II) atoms at 294 K and has a moderate antiferromagnetic interaction (J=-81.2 cm(-1)) between the two Fe(II) centres, while 2 was made up of 27.7% HS and 72.3% LS Fe(II) atoms at 300 K. The optical band gaps (Eo) for 1 were 1.9 eV (from absorption spectrum) and 2.2 eV (from fluorescence spectrum), electrochemical bandgap (Ee) was 0.83 eV, excited state lifetime (τ) was 0.67 ns, and formal redox potential (E'(FeIII/FeII)) was +0.63 V. The corresponding values for 2 were 3.5 eV (from absorption spectrum), 1.8 eV (from fluorescence spectrum), 0.69 eV, 2.8 ns, and +0.41 V.
  2. Roslan MF, Al-Shetwi AQ, Hannan MA, Ker PJ, Zuhdi AWM
    PLoS One, 2020;15(12):e0243581.
    PMID: 33362200 DOI: 10.1371/journal.pone.0243581
    The lack of control in voltage overshoot, transient response, and steady state error are major issues that are frequently encountered in a grid-connected photovoltaic (PV) system, resulting in poor power quality performance and damages to the overall power system. This paper presents the performance of a control strategy for an inverter in a three-phase grid-connected PV system. The system consists of a PV panel, a boost converter, a DC link, an inverter, and a resistor-inductor (RL) filter and is connected to the utility grid through a voltage source inverter. The main objective of the proposed strategy is to improve the power quality performance of the three-phase grid-connected inverter system by optimising the proportional-integral (PI) controller. Such a strategy aims to reduce the DC link input voltage fluctuation, decrease the harmonics, and stabilise the output current, voltage, frequency, and power flow. The particle swarm optimisation (PSO) technique was implemented to tune the PI controller parameters by minimising the error of the voltage regulator and current controller schemes in the inverter system. The system model and control strategies were implemented using MATLAB/Simulink environment (Version 2020A) Simscape-Power system toolbox. Results show that the proposed strategy outperformed other reported research works with total harmonic distortion (THD) at a grid voltage and current of 0.29% and 2.72%, respectively, and a transient response time of 0.1853s. Compared to conventional systems, the PI controller with PSO-based optimization provides less voltage overshoot by 11.1% while reducing the time to reach equilibrium state by 32.6%. The consideration of additional input parameters and the optimization of input parameters were identified to be the two main factors that contribute to the significant improvements in power quality control. Therefore, the proposed strategy effectively enhances the power quality of the utility grid, and such an enhancement contributes to the efficient and smooth integration of the PV system.
  3. Nasoha NZ, Luthfi AAI, Roslan MF, Hariz HB, Bukhari NA, Manaf SFA
    Sci Rep, 2023 Nov 07;13(1):19284.
    PMID: 37935748 DOI: 10.1038/s41598-023-46061-8
    This study explores utilizing pineapple peel (PP) hydrolysate as a promising carbon source for xylitol production, covering scopes from the pre-treatment to the fermentation process. The highest xylose concentration achieved was around 20 g/L via mild acid hydrolysis (5% nitric acid, 105 °C, 20-min residence time) with a solid loading of 10%. Two sets fermentability experiments were carried out of varying pH levels in synthetic media that includes acetic acid as the main inhibitors and hydrolysate supplemented with diverse nitrogen source. The results revealed that pH 7 exhibited the highest xylitol production, yielding 0.35 g/g. Furthermore, urea was found to be a highly promising and cost-effective substitute for yeast extract, as it yielded a comparable xylitol production of 0.31 g/g with marginal difference of only 0.01 g/g compared to yeast extract further highlights the viability of urea as the preferred option for reducing xylitol production cost. The absence of a significant difference between the synthetic media and hydrolysate, with only a marginal variance of 0.35 to 0.32 g/g, implies that acetic acid is indeed the primary constraint in xylitol production using PP hydrolysate. The study sheds light on PP biomass's potential for xylitol production, aligning economic benefits with environmental sustainability and waste management.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)