Displaying all 2 publications

Abstract:
Sort:
  1. Zamri Radzi, Noor Hayaty Abu Kasim, Yahya, N.A., Gan, S.N., Daud, N.M., Saffai, L., et al.
    Ann Dent, 2007;14(1):46-51.
    MyJurnal
    The impact strength of a newly developed experimental polyurethane-based polymer which is derived from palm oil (Experimental PU) was compared with denture polymers; heat-cured and self cured polymethyl methacrylate (PMMA) and ® Eclipse , light-activated urethane dimethacrylate prosthetic resin system. Ten specimens were ® prepared using heat-cured PMMA (Meliodent Heat Cure, Heraeus Kulzer, Germany), self cured PMMA ® (Meliodent Rapid Repair, Heraeus Kulzer, ® Germany), Eclipse baseplate resin (Dentsply, USA) and Experimental PU material. Specimens were prepared following manu- facturer’s instructions except for the Experimental PU material where it was prepared in bulk and sectioned to the desired dimension, 64 x 6 x 4 mm. A ‘V’ notch of approximately 0.8mm in depth was machine cut across the 6mm width. Prior to the Charpy type impact test, specimens were soaked in a water bath for 50 hours at 37ºC. ® Eclipse baseplate resin showed the highest 2 impact strength (2.73 kJ/m ±0.54) followed by ® 2 Meliodent Rapid Repair (2.50kJ/m ±0.65), ® 2 Meliodent Heat Cure (1.96kJ/m ±0.42) and 2 Experimental PU (1.04kJ/m ±0.29). One-way ANOVA showed significant interaction between materials (p
  2. Othman SA, Saffai L, Wan Hassan WN
    Clin Oral Investig, 2020 Aug;24(8):2853-2866.
    PMID: 31754872 DOI: 10.1007/s00784-019-03150-1
    OBJECTIVES: To validate the accuracy and reproducibility of linear measurements of three-dimensional (3D) images and to compare the measurements with the direct anthropometry method on cleft lip and palate (CLP) patients.

    MATERIALS AND METHODS: Nineteen linear facial measurements were derived from 16 standardized surface landmarks obtained from 37 cleft patients (20 males, 17 females; mean age 23.84 years, standard deviation ± 6.02). They were taken manually with calipers and were compared with the digitally calculated distance on the 3D images captured using the VECTRA-M5 360° Imaging System with pre-marked landmarks. Another pair of 19 linear measurements were computed on the 3D images 2 weeks apart for intra- and inter-observer agreements. Statistical analyses used were paired t test, the Bland-Altman analysis, and the intra-class correlation coefficient (ICC) index.

    RESULTS: Most of the linear measurements showed no statistically significant differences between the proposed method and direct anthropometry linear measurements. Nevertheless, bias of the 3D imaging system is present in the linear measurements of the nose width and the upper vermillion height. The measurements' mean biases were within 2 mm, but the 95% limit of agreement was more than 2 mm. Intra- and inter-observer measurements generally showed good reproducibility. Four inter-observer measurements, the upper and lower face heights, nose width, and pronasale to left alar base were clinically significant.

    CONCLUSIONS: Measurements obtained from this 3D imaging system are valid and reproducible for evaluating CLP patients.

    CLINICAL RELEVANCE: The system is suitable to be used in a clinical setting for cleft patients. However, training of the operator is strictly advisable.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links