We present a ternary blend-based bulk heterojunction ITO/PEDOT:PSS/PFO-DBT: MEH-PPV:PC71BM/LiF/Al photodetector. Enhanced optical absorption range of the active film has been achieved by blending two donor components viz. poly[2,7-(9,9-di-octyl-fluorene)-alt-4,7-bis(thiophen-2-yl)benzo-2,1,3-thiadiazole] (PFO-DBT) and poly(2-methoxy-5(2'-ethylhexyloxy) phenylenevinylene (MEH-PPV) along with an acceptor component, i.e., (6,6)-phenyl-C71 hexnoic acid methyl ester. The dependency of the generation rate of free charge carriers in the organic photodetector (OPD) on varied incident optical power density was investigated as a function of different reverse biasing voltages. The photocurrent showed significant enhancement as the intensity of light impinging on active area of OPD is increased. The ratio of Ilight to Idark of fabricated device at -3 V was ~3.5 × 10(4). The dynamic behaviour of the OPD under on/off switching irradiation revealed that sensor exhibits quick response and recovery time of ∼800 ms and 500 ms, respectively. Besides reliability and repeatability in the photoresponse characteristics, the cost-effective and eco-friendly fabrication is the added benefit of the fabricated OPD.
In this study, our main objective is to find the impact of FDI and external debt on health outcomes in emerging Asian economies from 1991 to 2019. To that end, we have collected data for seven economies: Bangladesh, Malaysia, Philippines, Thailand, Sri Lanka, China, and India. We have relied on the panel ARDL (PARDL) method for empirical analysis. The study's findings confirmed that the debt has increased infant mortality and decreased life expectancy in emerging Asian economies in the long run. On the other side, the FDI causes infant mortality to fall and life expectancy to rise in the long run in emerging Asian economies. Similarly, the health expenditures also reduced the infant mortality rate, though the impact is insignificant, and improved the life expectancy in emerging Asian economies. The causal analysis confirmed the two-way causality between health expenditure, infant mortality, and health expenditure and debt.
In this paper, we present the effect of varying humidity levels on the electrical parameters and the multi frequency response of the electrical parameters of an organic-inorganic composite (PEPC+NiPc+Cu2O)-based humidity sensor. Silver thin films (thickness ~200 nm) were primarily deposited on plasma cleaned glass substrates by the physical vapor deposition (PVD) technique. A pair of rectangular silver electrodes was formed by patterning silver film through standard optical lithography technique. An active layer of organic-inorganic composite for humidity sensing was later spun coated to cover the separation between the silver electrodes. The electrical characterization of the sensor was performed as a function of relative humidity levels and frequency of the AC input signal. The sensor showed reversible changes in its capacitance with variations in humidity level. The maximum sensitivity ~31.6 pF/%RH at 100 Hz in capacitive mode of operation has been attained. The aim of this study was to increase the sensitivity of the previously reported humidity sensors using PEPC and NiPc, which has been successfully achieved.
In this study, porous cationic hydrogen (H+) conducting polymer blend electrolytes with an amorphous structure were prepared using a casting technique. Poly(vinyl alcohol) (PVA), chitosan (CS), and NH4SCN were used as raw materials. The peak broadening and drop in intensity of the X-ray diffraction (XRD) pattern of the electrolyte systems established the growth of the amorphous phase. The porous structure is associated with the amorphous nature, which was visualized through the field-emission scanning electron microscope (FESEM) images. The enhancement of DC ionic conductivity with increasing salt content was observed up to 40 wt.% of the added salt. The dielectric and electric modulus results were helpful in understanding the ionic conductivity behavior. The transfer number measurement (TNM) technique was used to determine the ion (tion) and electron (telec) transference numbers. The high electrochemical stability up to 2.25 V was recorded using the linear sweep voltammetry (LSV) technique.