Displaying publications 1 - 20 of 30 in total

Abstract:
Sort:
  1. Corno AF
    Ann Thorac Surg, 2014 May;97(5):1853.
    PMID: 24792290 DOI: 10.1016/j.athoracsur.2013.12.010
    Matched MeSH terms: Blood Vessel Prosthesis*
  2. Nor Elina NS, Naresh G, Hanif H, Zainal AA
    Med J Malaysia, 2013 Jun;68(3):239-44.
    PMID: 23749014 MyJurnal
    Matched MeSH terms: Blood Vessel Prosthesis Implantation*
  3. Muda AS, Ralib AR, Yaacob Y, Zakaria R, Bakar AA
    Malays J Med Sci, 2011 Oct;18(4):91-7.
    PMID: 22589679
    Endovascular treatment of wide-necked aneurysms poses a challenge for the endovascular therapist. The Y-stent-assisted technique has been used for stent-assisted coil embolisation for wide-necked bifurcation aneurysms. This technique has been described for basilar tip aneurysms and middle cerebral artery bifurcation aneurysms using Neuroform and Enterprise stents. We report 2 cases of wide-necked bifurcation aneurysms that were treated with Y-stent-assisted coil embolisation using a new, fully retrievable and detachable intracranial stent (Solitaire AB™). We describe the advantages of a fully retrievable and detachable stent and its feasibility of forming a Y configuration.
    Matched MeSH terms: Blood Vessel Prosthesis
  4. Sologashvili T, Saat SA, Tille JC, De Valence S, Mugnai D, Giliberto JP, et al.
    Eur J Pharm Biopharm, 2019 Jun;139:272-278.
    PMID: 31004790 DOI: 10.1016/j.ejpb.2019.04.012
    OBJECTIVE: Vascular prostheses for small caliber bypass grafts in cardiac and vascular diseases or for access surgery are still missing. Poly (Ɛ-caprolactone) (PCL) has been previously investigated by our group and showed good biocompatibility and mechanical properties in vitro and rapid endothelialisation, cellular infiltration and vascularisation in vivo yielding optimal patency in the abdominal aortic position. The aim of the present study is to evaluate our PCL graft in the carotid position and to compare its outcome to the grafts implanted in the abdominal aortic position.

    METHODS: PCL grafts (1 mm ID/10 mm long) were implanted into the left common carotid artery in 20 Sprague-Dawley rats and compared to our previously published series of abdominal aortic implants. The animals were followed up to 3, 6, 12 and 24 weeks. At each time point, in vivo compliance, angiography and histological examination with morphology were performed.

    RESULTS: PCL grafts showed good mechanical properties and ease of handling. The average graft compliance was 14.5 ± 1.7%/ mmHg compared to 7.8 ± 0.9% for the abdominal position and 45.1 ± 3.2%/ mmHg for the native carotid artery. The overall patency for the carotid position was 65% as compared to 100% in the abdominal position. Complete endothelialisation was achieved at 3 weeks and cell invasion was more rapid than in the aortic position. In contrast, intimal hyperplasia (IH) and vascular density were less pronounced than in the aortic position.

    CONCLUSION: Our PCL grafts in the carotid position were well endothelialised with early cellular infiltration, higher compliance, lower IH and calcification compared to the similar grafts implanted in the aortic position. However, there was a higher occlusion rate compared to our abdominal aorta series. Anatomical position, compliance mismatch, flow conditions may answer the difference in patency seen.

    Matched MeSH terms: Blood Vessel Prosthesis/adverse effects*; Blood Vessel Prosthesis Implantation/adverse effects; Blood Vessel Prosthesis Implantation/instrumentation; Blood Vessel Prosthesis Implantation/methods*
  5. Kumaraguru P, Mazri YM, Yaacob AF, Hanif H, Zainal AA, Lau JH
    Med J Malaysia, 2011 Oct;66(4):381-2.
    PMID: 22299568 MyJurnal
    Conventional open repair for Thoracoabdominal aortic aneurysm (TAA) is associated with high morbidity and mortality. Spinal cord ischemia (SCI), renal failure, bowel ischemia and mortality are established complications following this procedure. With the advent of endovascular stent technology, various novel approaches have been described to reduce these complications, namely fenestrated stent graft and hybrid procedure. We present a case of hybrid procedure in a pseudoaneurysm of descending thoracic aorta done in Kuala Lumpur Hospital.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/methods*
  6. Tay JWT, Leong YP
    Med J Malaysia, 2012 Feb;67(1):111-2.
    PMID: 22582560 MyJurnal
    A 68 year old man with significant cardiorespiratory risks factors presented with a ruptured thoracic aortic aneurysm (TAA). This was treated by emergency thoracic endovascular aneurysm repair (TEVAR) under general anaesthesia (GA). An incidental abdominal aortic aneurysm (AAA) was not treated. Eight months later, he presented with ruptured AAA. Due to the patient's compromised respiratory system, he underwent endovascular aneurysm repair (EVAR) under local anaesthesia (LA). He had a smoother post-operation recovery compared to the first repair under GA.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation*
  7. Choo GH
    J Interv Cardiol, 2009 Apr;22(2):117-20.
    PMID: 19379469 DOI: 10.1111/j.1540-8183.2009.00443.x
    Percutaneous bifurcation intervention is usually sufficient with a single-stent strategy. When the double-stent strategy is employed, higher restenosis and target lesion revascularization (TLR) rates are observed, especially at the side-branch ostium. The results may be improved, however, with refinement in techniques, for example, final kissing balloon inflation and double kissing balloon inflation.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/methods*
  8. Syed A, Zainal AA, Hanif H, Naresh G
    Med J Malaysia, 2012 Dec;67(6):610-2.
    PMID: 23770955 MyJurnal
    This is our initial report on the first 4 cases of infra-renal abdominal aortic aneurysm undergoing Endovascular Aneurysm Repair (EVAR) with local anaesthesia, controlled sedation and monitoring by an anaesthetist. All four patients were males with a mean age of 66.7 years. Only one required ICU stay of two days for cardiac monitoring due to bradycardia and transient hypotension post procedure. No mortality or major post operative morbidity was recorded and the mean hospital stay post procedure was 3.5 days (range 2-5 days).
    Matched MeSH terms: Blood Vessel Prosthesis Implantation
  9. Syed Alwi SA, Zainal Ariffin A, Hanif H, Naresh G
    Med J Malaysia, 2012 Oct;67(5):503-5.
    PMID: 23770868
    This is our initial report on the first 4 cases of infra-renal abdominal aortic aneurysms undergoing Endovascular Aneurysm Repair (EVAR) with local anaesthesia, controlled sedation and monitoring by an anaesthetist. All 4 patients were males with a mean age of 66.7 years. Only one (1) required ICU stay of 2 days for cardiac monitoring due to bradycardia and transient hypotension post procedure. No mortality or major post operative morbidity was recorded and the mean hospital stay post procedure was 3.5 days (range 2-5 days).
    Matched MeSH terms: Blood Vessel Prosthesis Implantation
  10. Abdullah F, Adeeb S
    Heart Surg Forum, 2003;6(3):E50-1.
    PMID: 12821439
    An alternative technique of superior vena cava obstruction bypass using bovine pericardial conduit is described. The patient in this case had recurrent bilateral thrombophlebitis and thrombosed saphenous veins. Most of the surgical techniques reported in the literature so far have described the use of polyethylene terephthalate (Dacron) graft, polytetrafluoroethylene graft, autologous pericardial patch, and spiral vein graft. The use of synthetic grafts has been plagued with high rates of thrombosis. The pathology, clinical presentation, surgical technique, and outcome are discussed.
    Matched MeSH terms: Blood Vessel Prosthesis; Blood Vessel Prosthesis Implantation/methods*
  11. Promphan W, Han Siang K, Prachasilchai P, Jarutach J, Makonkawkeyoon K, Siwaprapakorn W, et al.
    Catheter Cardiovasc Interv, 2020 09 01;96(3):E310-E316.
    PMID: 32299151 DOI: 10.1002/ccd.28892
    OBJECTIVES: To assess feasibility and early outcomes of using BeGraft Aortic stent in the treatment of aortic coarctation (CoA).

    BACKGROUND: BeGraft Aortic stent (Bentley InnoMed, Hechingen, Germany) allows large postdilation diameter up to 30 mm. With availability of lengths of 19-59 mm and lower stent profile, they can be used in native and recurrent CoA in adults and in pediatric patients.

    MATERIALS AND METHODS: This is a multicentre retrospective analysis of 12 implanted BeGraft Aortic stents in CoA between May 2017 and April 2019.

    RESULTS: Twelve patients aged 7.7-38 years (median 18.3 years) with body weight of 19.9-56 kg (median 45.5 kg). Eight patients (66%) had native juxtaductal CoA while four had recurrent CoA after previous surgical or transcatheter treatments. The stents were implanted successfully in all the patients with no serious adverse events. The length of the stents ranged from 27 to 59 mm and the implanted stent diameter varied from 12 to 18 mm. The median intraprocedural CoA pressure gradient decreased from 25 mmHg (range 16-66 mmHg) to 2 mmHg (range 0-13 mmHg). The mean follow-up duration was 10.2 months. Two patient (16.6%) had residual stent narrowing requiring staged redilation. One patient (8%) had pseudoaneurysm formation at 1 year cardiac CT follow-up.

    CONCLUSIONS: The BeGraft Aortic stent may be considered to be safe and effective in the short term in treatment of CoA from childhood to adulthood. Long-term follow-up is needed.

    Matched MeSH terms: Blood Vessel Prosthesis*; Blood Vessel Prosthesis Implantation/adverse effects; Blood Vessel Prosthesis Implantation/instrumentation*
  12. Sachithanandan A, Badmanaban B
    Interact Cardiovasc Thorac Surg, 2011 Jul;13(1):100.
    PMID: 21697404 DOI: 10.1510/icvts.2010.265264A
    Matched MeSH terms: Blood Vessel Prosthesis Implantation*
  13. Hussein H, Azizi ZA
    Asian J Surg, 2008 Apr;31(2):87-9.
    PMID: 18490221 DOI: 10.1016/S1015-9584(08)60064-0
    A 62-year-old man presented with continuous, persistent backache shortly after completion of antituberculosis medication for tuberculosis (TB) of the spine. Computed tomography scan revealed a pseudoaneurysm involving the infrarenal aorta. He was restarted on anti-TB medication and underwent repair of the pseudoaneurysm with an in situ silver-coated bifurcated Dacron graft. His postoperative recovery was uneventful and he remained well up to 12 months of follow up. To our knowledge, this is the first case in the literature where an in situ silver-impregnated vascular graft has been successfully used in treating a tuberculous pseudoaneurysm.
    Matched MeSH terms: Blood Vessel Prosthesis*
  14. Kannan RY, Sales KM, Salacinski HJ, Butler PE, Seifalian AM
    Med J Malaysia, 2004 May;59 Suppl B:107-8.
    PMID: 15468841
    Matched MeSH terms: Blood Vessel Prosthesis*
  15. Kannan RY, Sales KM, Salacinski HJ, Butler PE, Seifalian AM
    Med J Malaysia, 2004 May;59 Suppl B:99-100.
    PMID: 15468837
    Matched MeSH terms: Blood Vessel Prosthesis*
  16. Khang NC, Zainal AA
    Med J Malaysia, 2016 02;71(1):17-22.
    PMID: 27130738
    BACKGROUND: This is a single institutional review of aortoiliac pseudoaneurysm of various aetiologies managed with endovascular stent graft repair.

    METHODS: From 2009 to 2014, 16 patients had endovascular stent graft inserted for pseudoaneurysm of the thoracic aorta, abdominal aorta and iliac arteries in Hospital Kuala Lumpur. Co-morbidity, causative agents, in-hospital mortality, complications and outcomes were examined.

    RESULTS: The average age was 59.1 years (range 36-77). Comorbidities include hypertension, diabetes mellitus, tuberculosis, prior infection and previous open aneurysmal repair. All patients had raised WBC (>10.0x10(9) /L), ESR or Creactive protein on admission while 50% of patients had fever. Blood cultures were positive in 4 patients. All patients were given antibiotics. Only one in-hospital mortality was noted at day-47 post-procedure. Two patients died of aortoenteric fistula at district hospital eight and 16 months later. One patient died of chronic graft infection two years later. One died of unrelated cause. One patient developed type IB endoleak from internal iliac artery two years later and surgical ligation was performed. The average follow up was 15.8 months.

    CONCLUSION: Endovascular stent graft repair for pseudoaneurysm is a viable option compared to open surgery. It is less invasive, has lower operative morbidity and fair outcomes. However, some cases may be due to inflammatory aortitis instead of infective pseudoaneurysm, given the frequent culture-negative results. In order to obtain high yield of bacteria culture for infected pseudoaneurysm, open repair with tissue culture is still the main mode of treatment especially for patients with low comorbidity.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation*
  17. Kakavand M, Yazdanpanah G, Ahmadiani A, Niknejad H
    J Tissue Eng Regen Med, 2017 06;11(6):1701-1709.
    PMID: 26190586 DOI: 10.1002/term.2064
    Amniotic membrane (AM), a placenta-derived natural biomaterial, has several characteristics which make it a potential substitute for blood vessels. However, there are no reports on the effects of the AM on blood components. The aim of this study was to evaluate the blood compatibility of the epithelial and mesenchymal surfaces of the amnion for potential use in vascular tissue engineering. The activation of intrinsic and extrinsic pathways of the clotting system, haemolysis and platelet adhesion were studied and the results were compared with heparin-coated expanded polytetrafluoroethylene (ePTFE) as a standard synthetic vascular graft. Prothrombin time (PT), activated partial thromboplastin time (aPTT), clotting time (CT) and haemolysis (%) tests showed that both the epithelial and mesenchymal sides of the AM are haemocompatible. Platelet aggregation and P-selectin production from the platelets showed that the epithelial surface of the AM has less induction of platelet activation than ePTFE. The results of scanning electron microscopy (SEM) demonstrated that platelets in contact with ePTFE had a higher rate of adhesion than with the epithelial and mesenchymal surfaces of the AM. Moreover, the morphological distribution of the platelets showed that the majority of platelets were round, while a large number of cells on ePTFE were dendritic. These results suggest that the AM which contains epithelial and mesenchymal stem cells has appropriate haemocompatibility to be employed in vascular tissue engineering, especially as a vein substitute. Copyright © 2015 John Wiley & Sons, Ltd.
    Matched MeSH terms: Blood Vessel Prosthesis*
  18. Krishna Moorthy PS, Saat SA, Sakijan AS
    Med J Malaysia, 2019 02;74(1):94-96.
    PMID: 30846673
    This is a case report of single-stage total thoracic aortic repair by the frozen elephant trunk technique for a 75-yearold female with a complex aortic pathology of mega-aorta extending from the ascending aorta to the descending aorta. We used a Thora flex™ Hybrid device, a frozen elephant trunk device with four branched grafts and the distal stent graft. The distal stent graft was inserted into the downstream descending aorta via an aortic arch and positioned 15 cm beyond the left subclavian artery after total arch replacement had been performed using a four-branch graft. The postoperative course was unremarkable with no complications. A post procedural computed tomography scan demonstrated complete exclusion of the descending thoracic aneurysm without endoleak. Therefore, fixing the whole mega-aorta in a single stage using the frozen elephant trunk was effective and safe.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/methods
  19. Chanana BB, Chandra P, Cheng JJ, Dick R, Gwon HC, Hiremath MS, et al.
    Int J Cardiol, 2016 Nov 01;222:832-40.
    PMID: 27522385 DOI: 10.1016/j.ijcard.2016.07.273
    BACKGROUND & AIMS: Although Absorb Bioresorbable Vascular Scaffolds (A-BVS) are routinely used in the Asia-Pacific, there is little information on patient selection or deployment technique here. This document investigates the experiences of leading interventional cardiologists from the Asia-Pacific region with a focus on patient characteristics, deployment techniques and management.

    METHODS AND RESULTS: A detailed questionnaire was distributed to 28 highly-experienced interventional cardiologists ('Authors') from 13 Asia-Pacific countries. The results were discussed at a meeting on patient selection, technical consideration, deployment practices and patient management. Potential patient benefits of Absorb compared to metallic DES, the learning curve for patient selection and preparation, device deployment, and subsequent patient management approaches are presented.

    CONCLUSIONS: Current practices are derived from guidelines optimized for European patients. Differences in approach exist in the Asia-Pacific context, including limited access to imaging and frequency of occurrence of complex lesions. Nevertheless, the use of the Absorb BVS ('Absorb') in certain Asia-Pacific countries has flourished and practices here are continuing to mature.

    Matched MeSH terms: Blood Vessel Prosthesis/utilization*
  20. Subramaniam R, Mani MP, Jaganathan SK
    Cardiovasc Eng Technol, 2018 09;9(3):503-513.
    PMID: 29700782 DOI: 10.1007/s13239-018-0357-y
    In this study, a small vascular graft based on polyurethane (PU) blended with chitosan (Ch) nanoparticles was fabricated using electrospinning technique. Initially, the chitosan nanoparticles were synthesized using ionic gelation method. UV-Vis spectrophotometer confirmed the presence of synthesized Ch nanoparticles by exhibiting absorption peak at 288 nm and the Fourier-transform infrared spectroscopy (FTIR) analysis confirmed the existence of the chitosan. Further, the synthesized Ch nanoparticles showed size diameter in the range of 134 ± 58 nm as measured using ImageJ. In the electrospun PU/chitosan graft, the fiber diameter and pore size diameter was found to be reduced compared to the pure PU owing to incorporation of chitosan into PU matrix. The FTIR spectrum revealed the presence of chitosan in the prepared nanocomposite membrane by the formation of the hydrogen bond and peak shift of CH and NH stretching. Moreover, the contact angle measurements revealed that the prepared graft showed decreased contact angle indicating hydrophilic nature compared to the pristine PU. The cytocompatibility studies revealed the non-toxic behavior of the fabricated graft. Hence, the prepared graft exhibiting significant physiochemical and non-toxic properties may be a plausible candidate for cardiovascular graft applications.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects; Blood Vessel Prosthesis Implantation/instrumentation*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links