METHODS: The systematic review and meta-analysis covered the period from 1989 to 2023. Multiple databases, including Embase, PubMed, Scopus, Web of Sciences (WoS), MagIran, Scientific Information Database (SID), and Google Scholar, were searched using validated keywords with MeSH and Emtree. The I2 index was used to check for heterogeneity among studies.
RESULTS: The review of 8 studies, with a sample size of 397,298 participants, showed high heterogeneity (I2: 97.8 %). Therefore, the random effects method was used to analyze the results. The prevalence of bleeding after intervention in percutaneous coronary arteries was reported to be 4.4 % (95%CI: 2-9.1).
CONCLUSION: This meta-analysis showed a significant prevalence of bleeding after PCI, highlighting the need for health policymakers to pay more attention to the complications associated with PCI. Interventional cardiologists should consider the effective factors in these bleeding and how to treat and control them due to the importance of this complication.
DESIGN: Single blinded, international, multicenter randomized controlled trial with 1:1 allocation ratio.
SETTING: Tertiary and University hospitals.
INTERVENTIONS: Patients (n=10,600) undergoing coronary artery bypass graft will be randomized to receive either volatile anesthetic as part of the anesthetic plan, or total intravenous anesthesia.
MEASUREMENTS AND MAIN RESULTS: The primary end point of the study will be one-year mortality (any cause). Secondary endpoints will be 30-day mortality; 30-day death or non-fatal myocardial infarction (composite endpoint); cardiac mortality at 30day and at one year; incidence of hospital re-admission during the one year follow-up period and duration of intensive care unit, and hospital stay. The sample size is based on the hypothesis that volatile anesthetics will reduce 1-year unadjusted mortality from 3% to 2%, using a two-sided alpha error of 0.05, and a power of 0.9.
CONCLUSIONS: The trial will determine whether the simple intervention of adding a volatile anesthetic, an intervention that can be implemented by all anesthesiologists, can improve one-year survival in patients undergoing coronary artery bypass graft surgery.
METHODS AND RESULTS: A detailed questionnaire was distributed to 28 highly-experienced interventional cardiologists ('Authors') from 13 Asia-Pacific countries. The results were discussed at a meeting on patient selection, technical consideration, deployment practices and patient management. Potential patient benefits of Absorb compared to metallic DES, the learning curve for patient selection and preparation, device deployment, and subsequent patient management approaches are presented.
CONCLUSIONS: Current practices are derived from guidelines optimized for European patients. Differences in approach exist in the Asia-Pacific context, including limited access to imaging and frequency of occurrence of complex lesions. Nevertheless, the use of the Absorb BVS ('Absorb') in certain Asia-Pacific countries has flourished and practices here are continuing to mature.
METHODS: We studied the systematic use of SBA with a low profile, non-slip element device prior to DCB angioplasty in an unselected, non-randomized patient population. This prospective, all-comers study enrolled patients with de novo lesions as well as in-stent restenotic lesions in bare metal stents (BMS-ISR) and drug-eluting stents (DES-ISR). The primary endpoint was the target lesion failure (TLF) rate at 9 months (ClinicalTrials.gov Identifier NCT02554292).
RESULTS: A total of 481 patients (496 lesions) were recruited to treat de novo lesions (78.4%, 377), BMS-ISR (4.0%, 19), and DES-ISR (17.6%, 85). Overall risk factors were acute coronary syndrome (ACS, 20.6%, 99), diabetes mellitus (46.8%, 225), and atrial fibrillation (8.5%, 41). Average lesion lengths were 16.7 ± 10.4 mm in the de novo group, and 20.1 ± 8.9 mm (BMS-ISR) and 16.2 ± 9.8 mm (DES-ISR) in the ISR groups. Scoring balloon diameters were 2.43 ± 0.41 mm (de novo), 2.71 ± 0.31 mm (BMS-ISR), and 2.92 ± 0.42 mm (DES-ISR) whereas DCB diameters were 2.60 ± 0.39 mm (de novo), 3.00 ± 0.35 mm (BMS-ISR), and 3.10 ± 0.43 mm (DES-ISR), respectively. The overall accumulated TLF rate of 3.0% (14/463) was driven by significantly higher target lesion revascularization rates in the BMS-ISR (5.3%, 1/19) and the DES-ISR group (6.0%, 5/84). In de novo lesions, the TLF rate was 1.1% (4/360) without differences between calcified and non-calcified lesions (p = 0.158) and small vs. large reference vessel diameters with a cutoff value of 3.0 mm (p = 0.901).
CONCLUSIONS: The routine use of a non-slip element scoring balloon catheter to prepare lesions suitable for drug-coated balloon angioplasty is associated with high procedural success rates and low TLF rates in de novo lesions.
OBJECTIVE: The primary objective of this study was to develop a new LSM scoring system and investigate the correlation between adherence to LSM and incidence of major adverse cardiac events (MACEs) at 12-month follow-up.
METHOD: A total of 1000 consecutive patients who underwent percutaneous transluminal coronary angioplasty (PTCA) were included in this prospective single-center study. Manipal lifestyle modification score (MLSMS) was developed by using five lifestyle-related factors. Adherence to LSM at the baseline and subsequent follow-ups was determined by using MLSMS. The MACE at 1-, 6-, and 12-month follow-up were analyzed.
RESULTS: There was a significant reduction in overall adherence to LSM (p