MATERIAL AND METHODS: Sandblasted and cleansed planar titanium specimens with a size of 5 × 5 × 1 mm were coated on one side with 0.25 vol% eicosapentaenoic acid (EPA). The other side of the specimens was kept highly polished (the control side). These specimens were inserted in rabbit mandibles. Twelve rabbits were randomly assigned into three study groups (n = 4). The rabbits were sacrificed at 4, 8, and 12 weeks. The harvested specimens with the implants were assessed for new bone formation on both sides of the implant using CBCT, conventional radiographs, and the biaxial pullout test. The results were statistically analyzed by a nonparametric Kruskal-Wallis test and Friedman's test as multiple comparisons and by Brunner-Langer nonparametric mixed model approach (R Software).
RESULTS: A significant osteoconductive bone formation was found on the EPA-coated Ti implant surface (P < 0.05) at 8 weeks when compared to the polished surface (control). Biaxial pullout test results showed a significant difference (P < 0.05) after 8 and 12 weeks with a maximum force of 243.8 N, compared to 143.25 N after 4 week.
CONCLUSION: EPA implant coating promoted osteoconduction on the Ti implant surfaces, enhancing the anchorage of the implant to the surrounding bone in white New Zealand rabbits.
MATERIAL AND METHODS: Thirty-four patients (mean age 60.70 ± 8.7 years) received telescopic crown or locator attachments for ISOD and completed OHIP-14 (Malaysian version) and DS questionnaires, at baseline (T0 ) with new conventional complete dentures (CCD) and 3 months (T1 ) and 3 years (T2 ) after ISOD conversion. Mandibular bone volume was calculated from cone beam computed tomography (CBCT) datasets using Mimics software. Mean changes (MC) in OHIP-14 and DS at intervals were analyzed using the Wilcoxon signed-rank test and effect size (ES). The association of bone volume, implant attachment type, and other patient variables with the change in OHIP-14 and DS were determined using multivariate linear regression analysis.
RESULTS: The MC in OHIP-14 and DS scores from T0 to T1 and T2 showed significant improvement with moderate and large ES, respectively. Regression analyses for the change in OHIP-14 score from T0 to T2 showed significant association with implant attachment type (P = 0.043), bone volume (P = 0.004), and baseline OHIP-14 (P = 0.001), while for DS, the association was only significant with baseline DS score (P = 0.001).
CONCLUSION: Improvement in patients' OHRQoL and satisfaction with ISOD was associated with their baseline ratings. Mandibular bone volume had a stronger association for improvement in OHRQoL compared to type of attachment.
METHODS: Twenty patients with two adjacent missing posterior teeth were recruited. Patients were assigned equally and randomly into two groups; Bicon(®) (6 or 8 mm) and Ankylos(®) (8 mm) implants. A two-stage surgical approach and single crowns were used for implant placement and loading. Outcomes included peri-implant clinical parameters, implant stability (Periotest values; PTVs) and peri-implant bone changes, which were assessed at baseline, 2, 6 and 12 months post-loading.
RESULTS: No implant loss was encountered up to 12 months post-loading. No significant difference in the clinical or radiographic parameters was observed except for PTVs (p < 0.05) that was lower in Ankylos(®) implants.
CONCLUSIONS: The use of short dental implants was associated with excellent 12 months clinical and radiographic outcomes. Ankylos(®) and Bicon(®) implants demonstrated similar peri-implant soft tissue and alveolar bone changes. However, Ankylos(®) implants demonstrated better implant stability at all evaluation intervals.