Displaying all 6 publications

Abstract:
Sort:
  1. Kassim ZH, Nor Hisham ND, Dardiri NA, Goot Heah K, Hazwani Baharuddin I, De Angelis N
    Minerva Stomatol, 2019 Dec;68(6):291-296.
    PMID: 32052617 DOI: 10.23736/S0026-4970.19.04242-0
    BACKGROUND: The aims of this study were to enumerate the primary implant stability quotient (ISQ) value of self-tapping dual etched implants and to explore the influence of parameters such as implant length, implant diameter, age, gender, implant location and osteotomy preparation on the ISQ value.

    METHODS: Retrospective data from clinical worksheets given to participants during two implant courses held between the periods of 2013 to 2014 were evaluated. A total of 61 implants were considered based on the inclusion criteria. The effects of parameters such as implant diameter, implant length, age, gender, implant location and osteotomy protocol on ISQ values were analyzed.

    RESULTS: Mean ISQ value for all implants was 67.21±9.13. Age of patients (P=0.016) and location of implants (P=0.041) had a significant linear relationship with the ISQ values. Within the age limit of the patients in this study, it was found that an increase in one year of patient's age results in 0.20 decrease in ISQ value (95% CI: -0.36, -0.04). However, placing an implant in the posterior maxilla may negatively affect the ISQ with a likely decrease in primary stability by 6.76 ISQ value (95% CI: -13.22, -0.30).

    CONCLUSIONS: The results suggest that the mean ISQ achieved by the participants were comparable with the range reported for this particular type of implants. The patient's age and location of implants were elucidated as the determinant factors of primary implant stability.

    Matched MeSH terms: Dental Prosthesis Retention
  2. Lui JL
    Quintessence Int, 1999 Sep;30(9):601-6.
    PMID: 10765865
    The introduction of an intraradicular composite reinforcing technique, in conjunction with the reestablishment of matching post canal spaces, has allowed compromised, root-filled teeth to be restored with functional, esthetic post crowns. This clinical case report suggests that reconstituted post canals, in accurately adapting to passive, parallel-sided, matching, and well-fitting posts, can enhance the retention of post crowns. Other factors of clinical importance relating to the resin-reinforced technique are discussed, including fracture resistance, depth of polymerization, dentin adhesion, polymerization shrinkage, and coronal microleakage.
    Matched MeSH terms: Dental Prosthesis Retention*
  3. Rahman SA, Muhammad H, Haque S, Alam MK
    J Contemp Dent Pract, 2019 Feb 01;20(2):173-178.
    PMID: 31058631
    AIM: The aim of this study was to evaluate the changes in the peri-implant hard and soft tissues and implant stability and to assess the correlation of bone loss and peri-implant probing depth with implant stability.

    MATERIALS AND METHODS: Twenty-one patients with implants were included in this study and implants were assessed by resonance frequency analysis (RFA). Bone levels of the implants were assessed by measuring mesial and distal bone levels from the periapical radiograph, and soft tissue was assessed from probing depth using a periodontal probe. Implants were assessed for stability and probing depth at pre-loading, at 3 months and 6 months post-loading. RFA and probing depth were statistically compared from different time points. Correlation of probing depth and marginal bone loss with implant stability was also determined.

    RESULTS: The average change in implant stability quotient (ISQ) measurements from pre-loading to 6 months post-loading was found to be statistically significant (p <0.005). The average probing depth reduced from 1.767 mm at pre-loading to 1.671 mm at post-loading 3 months, and 1.600 mm at post-loading 6 months. At 6 months of function, radiographic examination yielded 0.786 mm mesial bone loss and 0.8 mm distal bone loss. It was found to be statistically significant (p <0.005) but within an acceptable range. No significant correlation was found between implant stability and bone loss; and implant stability and probing depth.

    CONCLUSION: The study revealed an increasing trend in implant stability values with the time that indicates successful osseointegration. Increasing mean values for mesial and distal bone loss were also found.

    CLINICAL SIGNIFICANCE: The success of dental implants is highly dependent on the quality of bone and implant-bone interface, i.e., osseointegration. The most important factors that influence the survival rate of an implant is initial stability. The present study found the changes in the peri-implant hard and soft tissues and implant stability. This article, while being a prospective study, may show the evidence of successful osseointegration by increasing trend in implant stability (RFA) values with time which can help to the clinician in the long-term management of implants.

    Matched MeSH terms: Dental Prosthesis Retention
  4. Baig MR, Rajan G
    Indian J Dent Res, 2010 Apr-Jun;21(2):311-3.
    PMID: 20657109 DOI: 10.4103/0970-9290.66635
    This article describes the immediate placement and loading of implants in the aesthetic zone using an implant-retained, fixed prosthesis with a modified design. One section of the implant prosthesis has cemented crowns and the other section is the conventional screw-retained. This combined approach significantly offsets the unsuitable implant position, alignment or angulation, while ensuring the easy retrievability, repair and maintenance of the prosthesis at the same time.
    Matched MeSH terms: Dental Prosthesis Retention/instrumentation*
  5. Al-Juboori MJ, AbdulRahaman SB, Hassan A
    Implant Dent, 2013 Aug;22(4):351-5.
    PMID: 23811720 DOI: 10.1097/ID.0b013e318296583d
    To detect the correlation between crestal bone resorption and implant stability during healing period using resonance frequency analysis (RFA).
    Matched MeSH terms: Dental Prosthesis Retention
  6. Buzayan MM, Ariffin YT, Yunus N
    J Prosthodont, 2013 Oct;22(7):591-5.
    PMID: 23551843 DOI: 10.1111/jopr.12036
    A method is described for the fabrication of a closed hollow bulb obturator prosthesis using a hard thermoforming splint material and heat-cured acrylic resin. The technique allowed the thickness of the thermoformed bulb to be optimized for weight reduction, while the autopolymerized seal area was covered in heat-cured acrylic resin, thus eliminating potential leakage and discoloration. This technique permits the obturator prosthesis to be processed to completion from the wax trial denture without additional laboratory investing, flasking, and processing.
    Matched MeSH terms: Dental Prosthesis Retention
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links