Displaying all 3 publications

Abstract:
Sort:
  1. Ngeow WC, Lian CB
    Singapore Dent J, 1996 Jul;21(1):16-8.
    PMID: 10597177
    Fractures of the mandible and their management are discussed in detail in textbooks and articles dealing with facial trauma. This paper presents the management and treatment of a case of a unilateral comminuted and complicated fracture of the mandible due to dog attack on a geriatric patient. The attack also severed the patient's right arm. Due to the severity of the trauma, an emergency surgery was performed on the mandible and arm.
    Matched MeSH terms: Fractures, Comminuted/surgery*
  2. Chung WH, Eu WC, Chiu CK, Chan CYW, Kwan MK
    J Orthop Surg (Hong Kong), 2019 12 27;28(1):2309499019888977.
    PMID: 31876259 DOI: 10.1177/2309499019888977
    PURPOSE: To describe the reduction technique of thoracolumbar burst fracture using percutaneous monoaxial screws and its radiological outcomes compared to polyaxial screws.

    METHODS: All surgeries were performed by minimally invasive technique with either percutaneous monoaxial or percutaneous polyaxial screws inserted at adjacent fracture levels perpendicular to both superior end plates. Fracture reduction is achieved with adequate rod contouring and distraction maneuver. Radiological parameters were measured during preoperation, postoperation, and follow-up.

    RESULTS: A total of 21 patients were included. Eleven patients were performed with monoaxial pedicle screws and 10 patients performed with polyaxial pedicle screws. Based on AO thoracolumbar classification system, 10 patients in the monoaxial group had A3 fracture type and 1 had A4. In the polyaxial group, six patients had A3 and four patients had A4. Total correction of anterior vertebral height (AVH) ratio was 0.30 ± 0.10 and 0.08 ± 0.07 in monoaxial and polyaxial groups, respectively (p < 0.001). Total correction of posterior vertebral height (PVH) ratio was 0.11 ± 0.05 and 0.02 ± 0.02 in monoaxial and polyaxial groups, respectively (p < 0.001). Monoaxial group achieved more correction of 13° (62.6%) in local kyphotic angle compared to 8.2° (48.0%) in polyaxial group. Similarly, in regional kyphotic angle, 16.5° (103.1%) in the monoaxial group and 8.1° (76.4%) in the polyaxial group were achieved.

    CONCLUSIONS: Monoaxial percutaneous pedicle screws inserted at adjacent fracture levels provided significantly better fracture reduction compared to polyaxial screws in thoracolumbar fractures.

    Matched MeSH terms: Fractures, Comminuted/surgery*
  3. Mukundala VV, Lim HH
    Singapore Med J, 2001 Feb;42(2):82-4.
    PMID: 11358198
    Fracture-dislocation of the lumbo-sacral spine was an unusual injury and was divided into anterior, posterior and lateral types depending on the displacement of the cephalad portion of the spine over the caudal portion. According to the authors' knowledge, only 31 cases of traumatic fracture-dislocation of the lumbo-sacral spine were reported in the English literature. Only 3 previous reports referred to this injury with a posterior displacement, which was an even rarer injury. This was the fourth report of this type of injury.
    Matched MeSH terms: Fractures, Comminuted/surgery*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links