  1. Ng AH, Alqahtani MS, Jambi LK, Bugby SL, Lees JE, Perkins AC
    Br J Radiol, 2019 Jun;92(1098):20190020.
    PMID: 30864832 DOI: 10.1259/bjr.20190020
    OBJECTIVE: To examine the imaging capability of a novel small field of view hybrid gamma camera (HGC) using 125I seeds prior to surgical use.

    METHODS: The imaging performance of the camera system was assessed quantitatively and qualitatively at different source depths, source to collimator distances (SCD), activity levels, acquisition times and source separations, utilising bespoke phantoms.

    RESULTS: The system sensitivity and spatial resolution of the HGC for 125I were 0.41 cps/MBq (at SCD 48 mm) and 1.53 ± 0.23 mm (at SCD 10 mm) respectively. The camera was able to detect the 125I seed at a SCD of 63 mm (with no scattering material in place) in images recorded within a 1-min acquisition time. The detection of the seeds beneath scattering material (simulating deep-seated tumours) was limited to depths of less than 20 mm beneath the skin surface with a SCD of 63 mm and seed activity of 2.43 MBq. Subjective assessments of the hybrid images acquired showed the capability of the HGC for localising the 125I seeds.

    CONCLUSION: This preliminary ex vivo study demonstrates that the HGC is capable of detecting 125I seeds and could be a useful tool in radioactive seed localisation with the added benefit of providing hybrid optical γ images for guiding breast conserving surgery.

    ADVANCES IN KNOWLEDGE: The SFOV HGC could provide high resolution fused optical-gamma images of 125I radioactive seeds indicating the potential use in intraoperative surgical procedure such as RSL.

    Matched MeSH terms: Gamma Cameras/standards*
  2. Velo P, Zakaria A
    J Med Imaging Radiat Sci, 2017 Mar;48(1):39-42.
    PMID: 31047208 DOI: 10.1016/j.jmir.2016.10.010
    It is important to monitor the spatial resolution of a gamma camera on a weekly basis to acquire medical images with accurate quantitative information. A simple and fast computer program with a graphical user interface to analyze spatial resolution was successfully developed using MATLAB. The results were compared with those obtained from the standard processing system available in our gamma camera. The spatial resolution calculated using MATLAB was 1.24% lower than using the standard processing system. The developed program is cost effective, faster, and provides an easy platform for the physicists and technologists to analyze the spatial resolution based on the image of the line source.
    Matched MeSH terms: Gamma Cameras
  3. Sayed IS, Ismail SS
    Int J Biomed Imaging, 2020;2020:9239753.
    PMID: 32308670 DOI: 10.1155/2020/9239753
    In single photon emission computed tomography (SPECT) imaging, the choice of a suitable filter and its parameters for noise reduction purposes is a big challenge. Adverse effects on image quality arise if an improper filter is selected. Filtered back projection (FBP) is the most popular technique for image reconstruction in SPECT. With this technique, different types of reconstruction filters are used, such as the Butterworth and the Hamming. In this study, the effects on the quality of reconstructed images of the Butterworth filter were compared with the ones of the Hamming filter. A Philips ADAC forte gamma camera was used. A low-energy, high-resolution collimator was installed on the gamma camera. SPECT data were acquired by scanning a phantom with an insert composed of hot and cold regions. A Technetium-99m radioactive solution was homogenously mixed into the phantom. Furthermore, a symmetrical energy window (20%) centered at 140 keV was adjusted. Images were reconstructed by the FBP method. Various cutoff frequency values, namely, 0.35, 0.40, 0.45, and 0.50 cycles/cm, were selected for both filters, whereas for the Butterworth filter, the order was set at 7. Images of hot and cold regions were analyzed in terms of detectability, contrast, and signal-to-noise ratio (SNR). The findings of our study indicate that the Butterworth filter was able to expose more hot and cold regions in reconstructed images. In addition, higher contrast values were recorded, as compared to the Hamming filter. However, with the Butterworth filter, the decrease in SNR for both types of regions with the increase in cutoff frequency as compared to the Hamming filter was obtained. Overall, the Butterworth filter under investigation provided superior results than the Hamming filter. Effects of both filters on the quality of hot and cold region images varied with the change in cutoff frequency.
    Matched MeSH terms: Gamma Cameras
  4. Edam AN, Fornasier MR, De Denaro M, Sulieman A, Alkhorayef M, Bradley DA
    Appl Radiat Isot, 2018 Nov;141:288-291.
    PMID: 30122471 DOI: 10.1016/j.apradiso.2018.07.027
    Patient radiation dose and image quality are primary issues in the conduct of nuclear medicine (NM) procedures. A range of protocols are currently used in image acquisition and analysis of quality control (QC) tests, with National Electrical Manufacturers Association (NEMA) methods and protocols widely accepted in providing an accurate description, measurement and report of γ-camera performance parameters. However, no standard software is available for image analysis. Present study compares vendor QC software analysis and three types of software freely downloadable from the internet: NMQC, NM Toolkit and ImageJ-NM Toolkit software. These were used for image analysis of QC tests of γ-cameras based on NEMA protocols including non-uniformity evaluation. Ten non-uniformity QC images were obtained using a dual head γ-camera installed in Trieste General Hospital and then analyzed. Excel analysis was used as the baseline calculation for the non-uniformity test according to NEMA procedures. The results of non-uniformity analysis showed good agreement between the independent types of software and Excel calculations (the average differences were 0.3%, 2.9%, 1.3% and 1.6% for the Useful Field of View (UFOV) integral, UFOV differential, Central Field of View (CFOV) integral and CFOV differential, respectively), while significant differences were detected following analysis using the company QC software when compared with Excel analysis (the average differences were 14.6%, 20.7%, 25.7% and 31.9% for the UFOV integral, UFOV differential, CFOV integral and CFOV differential, respectively). Compared to use of Excel calculations use of NMQC software was found to be in close accord. Variation in results obtained using the three types of software and γ-camera QC software was due to the use of different pixel sizes. It is important to conduct independent analyses tests in addition to using the vendor QC software in order to determine the differences between values.
    Matched MeSH terms: Gamma Cameras
  5. Das BK, Biswal BM, Bhavaraju M
    Malays J Med Sci, 2006 Jan;13(1):52-7.
    PMID: 22589591 MyJurnal
    X-ray mammography has been the backbone of early detection of breast cancer. Several large scale systematic studies have shown that judicious use of X-ray mammography can indeed save life. However, though reasonably sensitive, X-ray mammography lacks in specificity leading to many unnecessary biopsies. Scintimammography is a relatively new imaging method to demonstrate cancer tissue in the breast. A radiopharmaceutical agent (Tc-99m Sestamibi) is administered intravenously and images of the breast are taken under a Gamma Camera. There is no need for any manipulation like compression of the breast as required to be done during mammography. The radiopharmaceutical accumulates in the breast in the presence of cancer tissue which can easily be seen in the images. The affinity of the cancer tissue to this radiopharmaceutical is up to 9 times in comparison to normal breast tissue. Several multi centric studies with blinded image interpretation have established the sensitivity and specificity of scintimammography to be above 85 and 90 % respectively as compared to 89 and 14 % respectively for X-ray mammography. The positive and negative predictive values of scintimamography are 70 and 83 % as against 49 and 57 % respectively for X-ray mammography. With the increasing availability of Nuclear Medicine facilities it is expected that more and more patients will benefi with the use of this new imaging modality .
    Matched MeSH terms: Gamma Cameras
  6. Rohani MFM, Yonan SNM, Tagiling N, Zainon WMNW, Udin Y, Nawi NM
    Asian Spine J, 2020 Oct;14(5):629-638.
    PMID: 32213791 DOI: 10.31616/asj.2019.0308
    STUDY DESIGN: Retrospective study.

    PURPOSE: This study aims to semiquantitatively evaluate the standardized uptake value (SUV) of 99mTc-methylene diphosphonate (MDP) radionuclide tracer in the normal vertebrae of breast cancer patients using an integrated single-photon emission computed tomography (SPECT)/computed tomography (CT) scanner.

    OVERVIEW OF LITERATURE: Molecular imaging techniques using gamma cameras and stand-alone SPECT have traditionally been utilized to evaluate metastatic bone diseases. However, these methods lack quantitative analysis capabilities, impeding accurate uptake characterization.

    METHODS: A total of 30 randomly selected female breast cancer patients were enrolled in this study. The SUV mean (SUVmean) and SUV maximum (SUVmax) values for 286 normal vertebrae at the thoracic and lumbar levels were calculated based on the patients' body weight (BW), body surface area (BSA), and lean body mass (LBM). Additionally, 106 degenerative joint disease (DJD) lesions of the spine were also characterized, and both their BW SUVmean and SUVmax values were obtained. A receiver operating characteristic (ROC) curve analysis was then performed to determine the cutoff value of SUV for differentiating DJD from normal vertebrae.

    RESULTS: The mean±standard deviations for the SUVmean and SUVmax in the normal vertebrae displayed a relatively wide variability: 3.92±0.27 and 6.51±0.72 for BW, 1.05±0.07 and 1.75±0.17 for BSA, and 2.70±0.19 and 4.50±0.44 for LBM, respectively. Generally, the SUVmean had a lower coefficient of variation than the SUVmax. For DJD, the mean±standard deviation for the BW SUVmean and SUVmax was 5.26±3.24 and 7.50±4.34, respectively. Based on the ROC curve, no optimal cutoff value was found to differentiate DJD from normal vertebrae.

    CONCLUSIONS: In this study, the SUV of 99mTc-MDP was successfully determined using SPECT/CT. This research provides an approach that could potentially aid in the clinical quantification of radionuclide uptake in normal vertebrae for the management of breast cancer patients.

    Matched MeSH terms: Gamma Cameras