Displaying all 5 publications

Abstract:
Sort:
  1. Ong BB, Green M
    Am J Forensic Med Pathol, 2003 Mar;24(1):64-9.
    PMID: 12605001
    In a strict and conservative society like Malaysia, the number of cases of infanticide has continued to occur. The authors present two typical cases of infanticide in Malaysia. Case 1 concerned a body of a fully mature newborn fetus disposed in a rubbish bin. The head was traumatically amputated by the rubbish truck's compactor. The umbilical cord was still attached to the body, with no reddening around the insertion. The severed neck showed features consistent with post-mortem amputation. The significant finding was expanded crepitant lungs, which floated in water. The histology of the lungs showed expanded alveoli. It was concluded that the baby had been born alive, but no cause of death could be elicited. Case 2 concerned a decomposed mature newborn found in a scrub forest. The internal organs showed advanced putrefaction, the lungs being collapsed, congested, and hemorrhagic, typical of decomposed lungs. No conclusion could be made about the state of birth or the cause of death because of the putrefied state of the body. The two cases illustrate the typical cases and problems faced by pathologists locally and probably elsewhere in the world. Most of the bodies are found in a putrefied state. Pathologists have to ascertain not only maturity and live birth but also the cause of death, which may be very subtle or masked by putrefaction. The problems of diagnosis of live birth are discussed.
    Matched MeSH terms: Head/pathology
  2. Lee CK, Kwan MK, Merican AM, Ng WM, Saw LB, Teh KK, et al.
    Singapore Med J, 2014 Aug;55(8):436-8.
    PMID: 25189306
    INTRODUCTION: Hip arthroplasty is commonly performed worldwide. The objective of this study was to determine the diameter of the femoral head in the Malaysian population in relation to gender and race (i.e. among Malay, Chinese and Indian patients).

    METHODS: This was a retrospective cross-sectional study performed between January 1995 and December 2006, evaluating the femoral head diameters of all patients aged 50 years and above who underwent hemiarthroplasty at two major hospitals in Malaysia.

    RESULTS: A total of 945 femoral heads (663 women, 282 men) were evaluated. The mean age of the patients in our cohort was 75.2 ± 9.4 (range 50-101) years. The mean femoral head diameter (with intact articular cartilage) was 44.9 ± 3.2 (range 38-54) mm. In our study, men had a significantly larger mean femoral head diameter than women (47.7 ± 2.8 mm vs. 43.7 ± 2.4 mm; p < 0.05). Patients of Chinese ethnicity were also found to have significantly larger femoral head diameters, when compared among the three races studied (p < 0.05).

    CONCLUSION: Malaysians have a mean femoral head diameter of 44.9 ± 3.2 mm. Among our patients, Chinese patients had a significantly larger femoral head size than Malay and Indian patients. We also found that, in our cohort, men had significantly larger femoral head diameters than women.
    Matched MeSH terms: Femur Head/pathology
  3. Baharuddin MY, Salleh ShH, Zulkifly AH, Lee MH, Mohd Noor A
    Biomed Res Int, 2014;2014:692328.
    PMID: 25025068 DOI: 10.1155/2014/692328
    A morphology study was essential to the development of the cementless femoral stem because accurate dimensions for both the periosteal and endosteal canal ensure primary fixation stability for the stem, bone interface, and prevent stress shielding at the calcar region. This paper focused on a three-dimensional femoral model for Asian patients that applied preoperative planning and femoral stem design. We measured various femoral parameters such as the femoral head offset, collodiaphyseal angle, bowing angle, anteversion, and medullary canal diameters from the osteotomy level to 150 mm below the osteotomy level to determine the position of the isthmus. Other indices and ratios for the endosteal canal, metaphyseal, and flares were computed and examined. The results showed that Asian femurs are smaller than Western femurs, except in the metaphyseal region. The canal flare index (CFI) was poorly correlated (r < 0.50) to the metaphyseal canal flare index (MCFI), but correlated well (r = 0.66) with the corticomedullary index (CMI). The diversity of the femoral size, particularly in the metaphyseal region, allows for proper femoral stem design for Asian patients, improves osseointegration, and prolongs the life of the implant.
    Matched MeSH terms: Femur Head/pathology
  4. Mohd Shukoor NS, Mohd Tamrin SB, Guan NY, Mohd Suadi Nata DH
    Work, 2018;60(1):129-134.
    PMID: 29843301 DOI: 10.3233/WOR-182741
    BACKGROUND: Hard hats are among the personal protective equipment (PPE) used in many industries to reduce the impact of any falling object on the skull and also to prevent head and brain injuries. However, the practice of wearing a safety helmet during working hours is still low. This is due to the physical discomfort perceived by safety helmet users.

    OBJECTIVE: Given the unpopularity of the current hard hat, the general perception of workers concerning its use and its measurements are the determining factors in the development of a new hard hat.

    METHOD: A cross-sectional study was conducted in which 132 male oil palm harvesters between 19 and 60 years of age were selected from among the employees of the same oil palm harvesting company. A set of questionnaires was developed to collect their socio-demographic information as well as their perceptions of comfort and the prevalence of head injury. In addition, a set of measuring instruments, including Martin's anthropometry set, was used for head measurement and data collection in respect of the current hard hat. In this research, six respondents were randomly selected to attend an interview session for qualitative assessment.RESULTSBased on the questionnaires, the unpopularity in the use of the hard hat was largely influenced by factors related to poor design, in general, and, specifically, poor ventilation (64%), load (67% ), and physical discomfort (42% ). The measurements of the anthropometric parameters and the dimensions of the hard hat also showed a significant mismatch.

    CONCLUSION: The unpopularity of the current hard hat among oil palm harvesters stemmed from the discomfort from wearing, which showed that the development of a new hard hat could lead to better usage and the greater likelihood of wearing a hard hat throughout the working day.

    Matched MeSH terms: Head/pathology
  5. Wong ML, Sandham A, Ang PK, Wong DC, Tan WC, Huggare J
    Eur J Orthod, 2005 Feb;27(1):91-7.
    PMID: 15743868
    The aim of this study was to measure craniofacial morphology and nasal respiratory resistance (NRR) in Malay, Indian and Chinese subjects with obstructive sleep apnoea (OSA). The sample consisted of 34 male subjects, 27-52 years of age (Malay n = 11, which included five mild and six moderate-severe OSA; Indian n = 11, which included six mild and five moderate-severe OSA; and Chinese n = 12, which included six mild and six moderate-severe OSA) diagnosed using overnight polysomnography. After use of a decongestant, NRR was recorded using anterior and posterior rhinomanometry. Standardized lateral cephalometric radiographs were used to record linear and angular dimensions. Malay subjects with moderate-severe OSA had a shorter maxillary (sp-pm) and mandibular (gn-go) length when compared with a mild OSA reference sample (P < 0.05). The hyoid bone was located more caudally in the Chinese moderate-severe subjects (hy-NL, hy-ML)(P < 0.05), and may be a useful diagnostic indicator for severity in this racial group. No pattern of differences for NRR was seen between the moderate-severe and mild OSA subjects. The consistently lower values for nasopharyngeal resistance in all the moderate-severe subjects when compared with the mild group may indicate that some compensation at this level of the airway had taken place. Strong positive correlations between craniocervical angulation (NL/OPT) and total airway resistance and the turbulent component of flow (k(2)) suggest that head posture is sensitive to fluctuations in airway resistance (P < 0.01).
    Matched MeSH terms: Head/pathology*
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links