Displaying all 10 publications

Abstract:
Sort:
  1. Ng BK, Lim PS, Shafiee MN, Ghani NA, Ismail NA, Omar MH, et al.
    Biomed Res Int, 2013;2013:587438.
    PMID: 24073412 DOI: 10.1155/2013/587438
    Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standard diagnostic methods for rupture of membranes and placental alpha microglobulin-1 immunoassay. The actual rupture of membranes was diagnosed on review of the medical records after delivery (absence of membrane or a positive pad chart). Main Outcome Measures. Placental alpha microglobulin-1 immunoassay and standard diagnostic methods for diagnosis of rupture of membrane. Results. A total of 211 patients were recruited. At initial presentation, 187 patients (88.6%) had ruptured membranes, while 24 patients (11.4%) had intact membranes. Placental alpha microglobulin-1 immunoassay confirmed rupture of membranes at initial presentation with a sensitivity of 95.7% (179 of 187), specificity of 100% (24 of 24), positive predictive value of 100% (179 of 179), and negative predictive value of 75.0% (24 of 32). By comparison, the conventional standard diagnostic methods had a sensitivity of 78.1% (146 of 187), specificity of 100% (24 of 24), positive predictive value of 100% (146 of 146), and negative predictive value of 36.9% (24 of 65) in diagnosing rupture of membrane. Conclusion. Placental alpha-microglobulin-1 immunoassay is a rapid and accurate method for confirming the diagnosis of rupture of membrane. It was superior to conventional standard diagnostic methods (pooling, nitrazine, and ferning), the nitrazine test alone or fern test alone.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  2. Chia WC, Khoo TS, Abdul Wahid SFS, Razak NFA, Alauddin H, Raja Sabudin RZA, et al.
    Ann Hematol, 2019 May;98(5):1279-1291.
    PMID: 30783731 DOI: 10.1007/s00277-019-03626-w
    Short tandem repeat (STR) analysis is used in chimerism monitoring after allogeneic hematopoietic stem cell transplantation (HSCT) for patients with various hematologic malignancies. Commercial forensic STR kits often contain loci with huge differences in power of discrimination (PD) across populations, causing some loci to be less informative for chimerism analysis in certain populations. This study aimed to construct a new STR multiplex panel with highly informative loci for efficient chimerism analysis. Thirteen STR markers which exhibit high PD (> 0.9) in at least 80% of 50 populations globally were selected to form a new panel and used in STR analysis of 253 Malaysian subjects. Cumulative power of discrimination (CPD) and combined power of exclusion (CPE) were determined from 253 Malaysian individuals. Loci informativity was assessed and compared to the commercial AmpFLSTR Identifiler PCR Amplification kit in 14 donor-recipient pairs. The new panel had detected 202 unique alleles including five novel alleles from the 253 individuals with high CPD and CPE (> 0.99999999999999999 and > 0.999999997 respectively). All loci from the new panel in the donor-recipient pair analysis showed higher than 50% informativity, while five loci from the commercial kit demonstrated lower than 50% informativity. Four loci from the new panel ranked the highest informativity. A sequenced allelic ladder which consists of 202 unique alleles from the 253 subjects was also developed to ensure accurate allele designation. The new 13-loci STR panel, thus, could serve as an additional powerful, accurate, and highly informative panel for chimerism analysis for HSCT patients.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  3. Jamaludin S, Mustaffa N, Che Hamzah NA, Syed Abdul Aziz SH, Lee YY
    BMC Gastroenterol, 2015;15:101.
    PMID: 26264957 DOI: 10.1186/s12876-015-0332-0
    Unchanged substrate in a negative rapid urease test may be reused to detect Helicobacter pylori (H. pylori). This could potentially reduce costs and wastage in low prevalence and resource-poor settings. We thus aimed to investigate the diagnostic accuracy of reused Pronto Dry and CLOtest kits, comparing this to the use of new Pronto Dry test kits and histopathological evaluation of gastric mucosal biopsies.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  4. Rahmah N, Taniawati S, Shenoy RK, Lim BH, Kumaraswami V, Anuar AK, et al.
    Trans R Soc Trop Med Hyg, 2002 1 31;95(6):601-4.
    PMID: 11816429
    A total of 753 serum samples from 6 institutions in 3 countries (Malaysia, Indonesia and India) were used to evaluate an immunochromatographic rapid dipstick test, Brugia Rapid, for diagnosis of Brugia malayi infection. The samples comprised sera from 207 microfilaria-positive individuals and 546 individuals from filaria non-endemic areas. The latter consisted of 70 individuals with soil-transmitted helminth infections, 68 with other helminth infections, 238 with protozoan infections, 12 with bacterial and viral infections and 158 healthy individuals. The dipstick is prepared with a goat anti-mouse antibody control line and a B. malayi recombinant-antigen test line. First, the dipstick is dipped into a well containing diluted patient serum, thus allowing specific anti-filarial antibody in the serum to react with the recombinant antigen. Then the dipstick is placed into an adjacent well containing reconstituted anti-human IgG4-gold. After 10 min, development of 2 red-purplish lines denotes a positive result and one line indicates a negative reaction. The overall results of the evaluation showed 97% sensitivity, 99% specificity, 97% positive predictive value and 99% negative predictive value. Brugia Rapid is thus a promising diagnostic tool for detection of B. malayi infection, and would be especially useful for the brugian filariasis elimination programme.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  5. Ooi BG, Sinniah M, Ismail S, Baharuddin R
    Malays J Pathol, 1996 Dec;18(2):89-93.
    PMID: 10879228
    The Serodia-HCV Particle Agglutination (HCV-PA) for the detection of HCV antibodies was compared with the Enzyme Immunoassay Test (UBI HCV EIA) for possible in-house use. A total of 150 specimens were analysed using UBI HCV EIA and Serodia-HCV PA. Of these, 80 (53.3%) were both PA and EIA positive and 59 (39.3%) were negative by both techniques. Eleven sera (7.4%) were found to be EIA-positive but PA-negative. These 11 discordant sera were further tested by the LiaTek-HCV III Immunoassay (Organon Teknika). Ten were found to be line immunoassay negative and one was line immunoassay positive. Failure of the PA to detect the HCV positive serum meant that a small proportion of HCV antibody positives may be missed by the PA test. We conclude that (i) EIA should continue to be the first line screening test in our laboratory, (ii) PA with its 100% specificity could be a useful supplementary screen for all EIA-positive sera and finally (iii) line immunoassay could be used on sera to resolve discordant results in the EIA and PA assays.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  6. Kelly DJ, Wong PW, Gan E, Chye CT, Cowan D, Lewis GE
    Am J Trop Med Hyg, 1990 Sep;43(3):301-7.
    PMID: 2121057
    Scrub typhus is a major cause of febrile illness throughout the Asia-Pacific region. It is commonly undiagnosed, partly because of the lack of a simple, reliable diagnostic test which can be used in clinical laboratories. The indirect immunoperoxidase technique, configured into a test kit, was provided to technicians who were trained in its use. They used the kit during a 2 year field trial in their respective clinical hospital laboratories throughout Malaysia. In an evaluation using 1,722 consecutive sera tested in those laboratories, the kit was found to have a median sensitivity for IgG detection of 0.85 (range 0.33-0.95), a median specificity of 0.94 (range 0.88-1.00), reproducibility of 0.86, and efficiency of 0.92 when compared to the reference laboratory. In a proficiency survey in which 10 laboratories received 3 coded test samples, all but 2 laboratories had results within 1 dilution of the reference laboratory in quantitating specific IgG, whereas 7 laboratories were within 1 dilution in quantitating IgM. The shelf life of the kit was at least 1 year at 4 degrees C.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  7. Rahmah N, Shenoy RK, Nutman TB, Weiss N, Gilmour K, Maizels RM, et al.
    Trop Med Int Health, 2003 Oct;8(10):895-900.
    PMID: 14516300
    A multicentre evaluation of the Brugia Rapid dipstick test was performed using 1263 serum samples in four international laboratories, i.e. T.D. Medical College (TDMC, India), National Institutes of Health (NIH, USA), Swiss Tropical Institute (STI, Switzerland) and Leiden University Medical Centre (LUMC, Netherlands). In comparison with microscopy, the dipstick demonstrated sensitivities of 97.2% (70 of 72) at TDMC, 91.6% (175 of 191) at LUMC and 100% (six of six) at STI. Sera of chronic patients showed a positivity rate of 11.3% (19 of 168) and 61.2% (71of 116) at TDMC and LUMC, respectively. All 266 sera of non-endemic normals from STI, NIH and LUMC tested negative with the dipstick. At LUMC, sera of 'endemic normals' (amicrofilaraemics with no clinical disease) from an area with approximately 35% microfilaria positivity showed 60.8% positive results (31 of 51), thus demonstrating the likelihood of many cryptic infections occurring in this population. Specificities of the test with Onchocerca volvulus sera were 98.8% (80 of 81) and 100% (10 of 10) at the NIH and STI, respectively; while specificity with Loa loa sera at the NIH was 84.6% (44 of 52). At the STI, the dipstick test also demonstrated 100% specificity when tested with 75 sera from various protozoan and helminthic infections.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  8. Zainol Rashid Z, Othman SN, Abdul Samat MN, Ali UK, Wong KK
    Malays J Pathol, 2020 Apr;42(1):13-21.
    PMID: 32342927
    INTRODUCTION: The World Health Organization (WHO) declared COVID-19 outbreak as a world pandemic on 12th March 2020. Diagnosis of suspected cases is confirmed by nucleic acid assays with real-time PCR, using respiratory samples. Serology tests are comparatively easier to perform, but their utility may be limited by the performance and the fact that antibodies appear later during the disease course. We aimed to describe the performance data on serological assays for COVID-19.

    MATERIALS AND METHODS: A review of multiple reports and kit inserts on the diagnostic performance of rapid tests from various manufacturers that are commercially available were performed. Only preliminary data are available currently.

    RESULTS: From a total of nine rapid detection test (RDT) kits, three kits offer total antibody detection, while six kits offer combination SARS-CoV-2 IgM and IgG detection in two separate test lines. All kits are based on colloidal gold-labeled immunochromatography principle and one-step method with results obtained within 15 minutes, using whole blood, serum or plasma samples. The sensitivity for both IgM and IgG tests ranges between 72.7% and 100%, while specificity ranges between 98.7% to 100%. Two immunochromatography using nasopharyngeal or throat swab for detection of COVID-19 specific antigen are also reviewed.

    CONCLUSIONS: There is much to determine regarding the value of serological testing in COVID-19 diagnosis and monitoring. More comprehensive evaluations of their performance are rapidly underway. The use of serology methods requires appropriate interpretations of the results and understanding the strengths and limitations of such tests.

    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  9. Khairullah NS, Lam SK
    PMID: 8629057
    In 1990 and 1991, six laboratories located in the WHO Western Pacific Region (WPR) and South East Asian Region (SEAR) were selected, based on their experience in the immunofluorescence antibody technique (IFAT), to participate in the evaluation of a WHO monoclonal antibody (Mab) kit to detect respiratory syncytial (RS) virus, influenza A virus, influenza B virus, parainfluenza virus and adenovirus. Despite differences in the initial standardization procedures, the WHO monoclonal antibodies were found to be of high quality, sensitivity and specificity when tested on clinical specimens. The constant supply of affordable high quality reagents from WHO would enable their use in clinical virological laboratories in the developing countries as well as promote the utilization of IFAT as an adjunct to cell culture isolation in the diagnosis of acute respiratory viral infections.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  10. Sekhar WY, Soo EH, Gopalakrishnan V, Devi S
    Singapore Med J, 2000 Aug;41(8):370-5.
    PMID: 11256343
    The aim of the study was to look into the epidemiology of serodiagnosed cases of leptospirosis at the University Hospital and compare two commercial ELISA Assays to the Microscopic Agglutination Test (MAT). Demographic data for all serodiagnosed cases for the years 1991-1997 were collected. From this data, 104 sera (n = 104) were selected as samples for comparative evaluation of the commercial ELISAs (INDX Dip-S-Ticks and PanBio ELISA) to the MAT test. Thirty two (n = 32) negative control sera were selected from serodiagnosed cases of other differential diagnosis of leptospira infection. The MAT test is a standard test that detects agglutination antibodies to leptospira biflexa, while the INDX Dip-S-Ticks is an ELISA dot test assaying for total anti-leptospira antibodies. The PanBio ELISA is a colorometric assay in test well strips to detect anti-leptospira IgM. The sensitivity, specificity, and efficiency of tests were calculated at a MAT cut-off value of 1:320. Demographic data showed that leptospirosis peaks during March-May and Aug-Nov coinciding with the inter-monsoon period with more men being infected than women and more adults than children. The sensitivity, specificity, and efficiency of test for the INDX Dip-S-Ticks were 83.3%, 93.8% and 87.5% while the values for the PanBio ELISA were 54.2%, 96.9% and 71.3%. The suboptimal PanBio result could be related to the blocking effect of high IgG titres or could be related to the diagnostic MAT cut-off values used in this study. The data hence reflects a pattern of transmission that is related to "wet" occupational risk factors. The commercial assays evaluated, are easier to perform but interpretation of results should be based on level of endemicity. The INDX Dip-S-Ticks allows this flexibility and is a practical alternative to the MAT test.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*