Displaying all 5 publications

Abstract:
Sort:
  1. Jayaranee S, Ramesh P, Nadesan V
    Singapore Med J, 2002 Aug;43(8):421-2.
    PMID: 12507029
    Immune haemolysis following renal transplantation has been reported and known causes include infection, medication and metabolic disturbances (1,2). Autoimmune haemolysis after renal transplantation secondary to ABO minor mismatch is an uncommon but important cause that should be considered in the differential diagnosis of post-transplantation haemolysis. A case of haemolytic anaemia caused by graft versus host antibody formation is presented. We suggest that direct Coomb's test should be done as a routine in all cases of ABO mismatch renal transplantation and red cells compatible with both donor and recipient or group "O" packed cells should be transfused if transfusion is indicated.
    Matched MeSH terms: Blood Group Incompatibility/complications*; Blood Group Incompatibility/immunology
  2. Gan CC, Jalalonmuhali M, Nordin NZ, Abdul Wahab MZ, Yahya R, Ng KP, et al.
    Transplant Proc, 2021 Apr;53(3):856-864.
    PMID: 33487455 DOI: 10.1016/j.transproceed.2020.10.038
    Malaysia has a low deceased-donor donation rate and has not embarked on a paired kidney exchange program; therefore, ABO-incompatible and HLA-incompatible transplantation remain the main contributor to the sustainability of the national kidney transplantation (KT) program. There were 26 cases of ABO-incompatible KTs performed from 2011 to 2018 in 3 major transplant centers, namely, Hospital Kuala Lumpur, University Malaya Medical Centre, and Prince Court Medical Centre. We collected perioperative and follow-up data through June 2019. The desensitization protocol varies and is center specific: the localized Japanese protocol and Swedish protocol with a target anti-A/B isoagglutinin titer of 16 or 32 on the day of transplant. The induction and tacrolimus-based maintenance protocol was nearly identical. The median follow-up time was 62.3 months (interquartile range, 37.0-79.7). Fifteen subjects had the highest predesensitization anti-A/B titer of ≥32 (57.7%). The acute cellular rejection and antibody-mediated rejection incidence were 12.5% (3 cases) and 8.3% (2 cases), respectively. Patient, graft, and death-censored graft survival rates were 96.2%, 92.3%, and 96.0%, respectively, 1 year post-living-donor KT (LDKT) and 96.2%, 87.2%, and 90.7%, respectively, 5 years post-LDKT. Our experience shows that ABO-incompatible LDKT using a suitable desensitization technique could be a safe and feasible choice for LDKT even with varied desensitization regimens for recipients with relatively high baseline isoagglutinin titers.
    Matched MeSH terms: Blood Group Incompatibility/immunology; Blood Group Incompatibility/mortality*
  3. Lim, N.L., Boo, N.Y., Nur Atiqah, N.A., Padma Soosai, A., Musa Mohd Nordin, M Sham. Kasim
    MyJurnal
    Severe jaundice (serum bilirubin level > 340 gmol/L) occurred in 81 infants admitted to the Neonatal Intensive Care Unit (NICU) of the Maternity Hospital Kuala Lumpur (MHKL) in 1993. Of these 46 (56.8%) underwent 53 exchange transfusions. In-patient case notes were available for study on 41 of them. Two infants had no cause identified while 12 were associated with prematurity, 13 ABO incompatibility, 8 G6PD deficiency, 6 sepsis 2 Rh isoimmunisation and 6 miscellaneous causes. In 14 infants it was felt that exchange transfusions might have been avoided if they were detected earlier and phototherapy instituted promptly. Twenty six (26) infants were deemed to have been given phototherapy at the appropriate time but jaundice increased to exchange transfusion levels, threshold values depending on the unit in charge. Use of higher intensity phototherapy might have been more effective in some of the cases. Available data showed similar outcomes in both groups.
    Matched MeSH terms: Blood Group Incompatibility
  4. Zulkeflee RH, Hassan MN, Hassan R, Saidin NIS, Zulkafli Z, Ramli M, et al.
    Transfus Apher Sci, 2023 Jun;62(3):103658.
    PMID: 36805153 DOI: 10.1016/j.transci.2023.103658
    Acute hemolytic transfusion reaction following ABO-incompatible platelet transfusion: two case reports An ideal platelet transfusion should provide ABO identical platelet concentrate, and cross match compatibility is not routinely performed in the standard practices. However, ABO non identical platelet transfusions are not uncommon with the limited resources and short shelf life of platelet concentrate. Though rare, acute hemolytic transfusion reaction (AHTR) may occur following minor ABO-incompatible platelet transfusion. Here, we report two cases of thrombocytopenic patients (one child and one adult) type as Group B RhD positive and received Group O RhD positive platelet transfusions. Both patients experienced an AHTR evidenced by a drop in hemoglobin level, spherocytosis and small agglutinations on the blood film, and positive direct Coombs test. They were treated symptomatically, recovered and discharged well post-event without any morbidity. No anti-B isohemagglutinins titer were done to confirm the high titer of the antibody in the platelet donors. Our cases highlighted the importance of ABO-compatible platelet transfusion, especially to children and those vigilant groups of patients.
    Matched MeSH terms: Blood Group Incompatibility
  5. Lie-Injo LE, Ng T, Balakrishnan S
    Clin Chim Acta, 1974 Jan 19;50(1):77-83.
    PMID: 4856203 DOI: 10.1016/0009-8981(74)90079-5
    Matched MeSH terms: Blood Group Incompatibility