Displaying all 11 publications

Abstract:
Sort:
  1. Sun C, Lee WG, Ma Q, Zhang X, Zhao Z, Cai X
    J Orthop Surg Res, 2023 Aug 08;18(1):586.
    PMID: 37553600 DOI: 10.1186/s13018-023-04023-w
    BACKGROUND: The positioning of implant components for total hip arthroplasty (THA) is essential for joint stability, polyethylene liner wear, and range of motion. One potential benefit of the direct anterior approach (DAA) for THA is the ability to use intraoperative fluoroscopy for acetabular cup positioning and limb-length evaluation. Previous studies comparing intraoperative fluoroscopy with no fluoroscopy during DAA have reported conflicting results. This meta-analysis aimed to evaluate whether intraoperative fluoroscopy improves component positioning compared to no fluoroscopy during direct anterior total hip arthroplasty.

    METHODS: A systematic review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was conducted. We searched Web of Science, EMBASE, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database in May 2023 to identify studies involving intraoperative fluoroscopy versus no fluoroscopy during direct anterior total hip arthroplasty. Finally, we identified 1262 hips assessed in seven studies.

    RESULTS: There were no significant differences in terms of acetabular cup inclination angle (ACIA, P = 0.21), ACIA within safe zone rate (P = 0.97), acetabular cup anteversion angle (ACAA, P = 0.26); ACAA within safe zone rate (P = 0.07), combined safe zone rate (P = 0.33), and limb-length discrepancy (LLD, P = 0.21) between two groups.

    CONCLUSION: Even though intraoperative fluoroscopy was not related to an improvement in cup location or LDD. With fewer experienced surgeons, the benefit of intraoperative fluoroscopy might become more evident. More adequately powered and well-designed long-term follow-up studies were required to determine whether the application of the intraoperative fluoroscopy for direct anterior total hip arthroplasty will have clinical benefits and improve the survival of prostheses.

    Matched MeSH terms: Hip Joint/surgery
  2. Soliman MM, Islam MT, Chowdhury MEH, Alqahtani A, Musharavati F, Alam T, et al.
    J Mater Chem B, 2023 Nov 15;11(44):10507-10537.
    PMID: 37873807 DOI: 10.1039/d3tb01469j
    The UK's National Joint Registry (NJR) and the American Joint Replacement Registry (AJRR) of 2022 revealed that total hip replacement (THR) is the most common orthopaedic joint procedure. The NJR also noted that 10-20% of hip implants require revision within 1 to 10 years. Most of these revisions are a result of aseptic loosening, dislocation, implant wear, implant fracture, and joint incompatibility, which are all caused by implant geometry disparity. The primary purpose of this review article is to analyze and evaluate the mechanics and performance factors of advancement in hip implants with novel geometries. The existing hip implants can be categorized based on two parts: the hip stem and the joint of the implant. Insufficient stress distribution from implants to the femur can cause stress shielding, bone loss, excessive micromotion, and ultimately, implant aseptic loosening due to inflammation. Researchers are designing hip implants with a porous lattice and functionally graded material (FGM) stems, femur resurfacing, short-stem, and collared stems, all aimed at achieving uniform stress distribution and promoting adequate bone remodeling. Designing hip implants with a porous lattice FGM structure requires maintaining stiffness, strength, isotropy, and bone development potential. Mechanical stability is still an issue with hip implants, femur resurfacing, collared stems, and short stems. Hip implants are being developed with a variety of joint geometries to decrease wear, improve an angular range of motion, and strengthen mechanical stability at the joint interface. Dual mobility and reverse femoral head-liner hip implants reduce the hip joint's dislocation limits. In addition, researchers reveal that femoral headliner joints with unidirectional motion have a lower wear rate than traditional ball-and-socket joints. Based on research findings and gaps, a hypothesis is formulated by the authors proposing a hip implant with a collared stem and porous lattice FGM structure to address stress shielding and micromotion issues. A hypothesis is also formulated by the authors suggesting that the utilization of a spiral or gear-shaped thread with a matched contact point at the tapered joint of a hip implant could be a viable option for reducing wear and enhancing stability. The literature analysis underscores substantial research opportunities in developing a hip implant joint that addresses both dislocation and increased wear rates. Finally, this review explores potential solutions to existing obstacles in developing a better hip implant system.
    Matched MeSH terms: Hip Joint/surgery
  3. Dwan LN, Gibbons P, Jamil K, Little D, Birke O, Menezes MP, et al.
    Hip Int, 2023 Mar;33(2):323-331.
    PMID: 34180253 DOI: 10.1177/11207000211027591
    BACKGROUND: Hip dysplasia is a lack of femoral head coverage and disruption of hip and acetabular alignment and congruency, with severity ranging from mild subluxation in nascent at-risk hips to complete dislocation. Presentation of hip dysplasia in neuromuscular conditions can be sub-clinical or associated with a limp with or without hip pain, abductor and flexor weakness and reduced hip range of motion. Untreated hip dysplasia leads to early onset osteoarthritis requiring hip arthroplasty in early adulthood. Hip dysplasia occurs in 6-20% of children with Charcot-Marie-Tooth disease, however little is known about the reliability and sensitivity of detection on plain film pelvic radiographs.

    METHODS: 14 common measures of hip dysplasia on anteroposterior pelvis radiographs were independently assessed by 2 orthopaedic specialists in 30 ambulant children with Charcot-Marie-Tooth disease. Hip health was also categorised based on clinical impression to assess the sensitivity of radiographic measures to identify hip dysplasia status.

    RESULTS: 8 measures (acetabular index, head width, lateral centre-edge angle, lateral uncoverage, medial joint width, migration percentage, neck shaft angle, triradiate status) exhibited 'excellent' reliability between clinical evaluators. 5 of the 30 patients (17%) were identified as having nascent hip dysplasia. Reliable radiographic measures that significantly distinguished between nascent hip dysplasia and healthy hips were acetabular index, lateral centre edge angle, medial joint width and migration percentage.

    CONCLUSIONS: We have identified a subset of reliable and sensitive radiographic hip measures in children with Charcot-Marie-Tooth disease to prioritise during hip screening to mitigate the deleterious effects of hip dysplasia, pain and disability in adulthood.

    Matched MeSH terms: Hip Joint/surgery
  4. Tai CC, Nam HY, Abbas AA, Merican AM, Choon SK
    J Arthroplasty, 2009 Dec;24(8):1200-4.
    PMID: 19682839 DOI: 10.1016/j.arth.2009.07.001
    We carried out a prospective study of 47 Exeter (Stryker Inc, Warsaw, Ind) small stem total hip arthroplasty in 42 patients with an average age of 58 years and a mean follow-up of 8.5 years. The Oxford hip score improved from a preoperative mean of 47 to 17 at last follow-up. More than 87% patients had excellent or good Harris hip scores, and 90% were able to walk with little or no pain. Stem subsidence within the cement mantle was observed in 26% of cases, and none showed evidence of aseptic loosening or implant failure. Two stems were removed due to infection. The survival rate of this implant was 95.7% at 10 years. This first series of Exeter small stem showed excellent medium-term results, comparable to its larger counterparts.
    Matched MeSH terms: Hip Joint/surgery*
  5. Merican AM, Randle R
    J Arthroplasty, 2006 Sep;21(6):846-51.
    PMID: 16950037
    The Fitmore titanium mesh cementless acetabular component in 115 hip arthroplasties was reviewed at an average of 33 months of follow-up. None were revised nor had infection. One hip dislocated 4 years postoperatively. Two femoral components were revised. The average Harris Hip Score at the last follow-up was 90 points. In the 96 sets of radiographs available, there was no loosening or new radiolucency. One hip had nonprogressive osteolysis adjacent to a screw. This press-fit cup has its polar region flattened and is rim loading. Noncontact (gaps) at the acetabular floor is expected and is not critical for fixation. In all but 6 hips, these gaps filled. In 5 hips, a minimal gap (
    Matched MeSH terms: Hip Joint/surgery
  6. Zubaidah AW, Lim VKE
    Med J Malaysia, 1996 Mar;51(1):134-6.
    PMID: 10967993
    A 31-year-old Pakistani man was admitted to hospital after sustaining a Grade I compound fracture of the mid-shaft of the left tibia and fibula following a motor vehicle accident. He developed septicaemic shock, acute renal failure and Group A streptococcal necrotizing fasciitis of the left leg. The patient underwent an above knee amputation followed by disarticulation of the left hip with extensive debridement. He was treated with benzylpenicillin, vancomycin, inotropes and continuous haemodialysis and survived without further sequelae. Subsequently, skin grafting was done over the wound site. This case highlights the role of Group A streptococcus as a cause of this rare and life-threatening infection.
    Matched MeSH terms: Hip Joint/surgery
  7. Abbas AA, Kim YJ, Song EK, Yoon TR
    J Arthroplasty, 2009 Oct;24(7):1144.e5-8.
    PMID: 18848418 DOI: 10.1016/j.arth.2008.09.008
    The causes of groin pain after total hip arthroplasty are numerous, and the condition itself is disabling. Therefore, it is imperative that the cause of the pain is identified and managed appropriately. We report a case where the patient had groin pain after total hip arthroplasty as a result of an oversized cementless acetabular component, which caused a breach in the anterior wall of the acetabulum. The anterior wall of the acetabulum was reconstructed with femoral head allograft, and the patient has been symptom free since.
    Matched MeSH terms: Hip Joint/surgery
  8. Yong KS, Kareem BA, Ruslan GN, Harwant S
    Med J Malaysia, 2001 Jun;56 Suppl C:57-60.
    PMID: 11814251 MyJurnal
    Sixty-seven primary THR surgeries in 57 patients between January 1992 and December 1998 were reviewed after a mean follow-up of 35.9 months. The rate of superficial and deep wound infections were 11.9% and 1.5% respectively. The most common organism in superficial wound infection was Staphylococcus aureus. The factors that were significantly associated with superficial wound infection were diabetes mellitus (p= 0.0230) obesity (p=0.0088). The patients who developed superficial wound infection have a significantly longer duration of surgery compared to patients without infection (p=0.014). However, there was no significant difference between the mean age among patients with and without superficial wound infection (p=0.814).
    Matched MeSH terms: Hip Joint/surgery
  9. Silva JF
    Int Orthop, 1980;4(2):79-81.
    PMID: 7429684 DOI: 10.1007/bf00271088
    Two hundred and nineteen patients with skeletal tuberculosis have been reviewed analysing the site of the lesion and the treatment given. Operative management is advocated since the results of this approach are encouraging.
    Matched MeSH terms: Hip Joint/surgery
  10. Muhamad Effendi F, Nam Y, Shin CH, Cho TJ, Yoo WJ, Cheon JE, et al.
    J Pediatr Orthop B, 2018 Sep;27(5):407-411.
    PMID: 28704300 DOI: 10.1097/BPB.0000000000000477
    Heterotopic ossification in soft tissue or muscle is rare in the pediatric and adolescent age group. Most cases are associated with musculoskeletal injury and trauma to the central nervous system. Here, we describe an adolescent patient without a history of trauma or lesions in the central nervous system who presented with a painful limp with limited motion of the left hip. Investigations indicated unusually large heterotopic ossification extending from the inner aspect of the ilium down to the anterior part of the hip, highly likely to have developed after an unrecognized periacetabular pyomyositis primarily involving the iliacus muscle. Surgical excision was performed successfully without perioperative complications. No recurrence was detected at the final follow-up.
    Matched MeSH terms: Hip Joint/surgery*
  11. Baharuddin MY, Salleh ShH, Hamedi M, Zulkifly AH, Lee MH, Mohd Noor A, et al.
    Biomed Res Int, 2014;2014:478248.
    PMID: 24800230 DOI: 10.1155/2014/478248
    Stress shielding and micromotion are two major issues which determine the success of newly designed cementless femoral stems. The correlation of experimental validation with finite element analysis (FEA) is commonly used to evaluate the stress distribution and fixation stability of the stem within the femoral canal. This paper focused on the applications of feature extraction and pattern recognition using support vector machine (SVM) to determine the primary stability of the implant. We measured strain with triaxial rosette at the metaphyseal region and micromotion with linear variable direct transducer proximally and distally using composite femora. The root mean squares technique is used to feed the classifier which provides maximum likelihood estimation of amplitude, and radial basis function is used as the kernel parameter which mapped the datasets into separable hyperplanes. The results showed 100% pattern recognition accuracy using SVM for both strain and micromotion. This indicates that DSP could be applied in determining the femoral stem primary stability with high pattern recognition accuracy in biomechanical testing.
    Matched MeSH terms: Hip Joint/surgery
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links