  1. Ngeow YF, Tan CH, Lim SY
    Med J Malaysia, 1992 Mar;47(1):15-9.
    PMID: 1387443
    Three building complexes in Kuala Lumpur were surveyed for the presence of legionellae in cooling towers. The organisms were grown from 12 out of 46 samples of water collected from 30 towers. L. pneumophila serogroups 1 and 7 were the commonest serogroups isolated. None belonged to the Pontiac subgroup of L. pneumophila serogroup 1.
    Matched MeSH terms: Legionella/isolation & purification*
  2. Lim EW, Meers PD
    Ann Acad Med Singap, 1989 Jul;18(4):348-51.
    PMID: 2679337
    A rapid method of assay, using a monoclonal antibody linked to alkaline phosphatase, was used for the detection of the Pontiac subgroup of Legionella pneumophila serogroup 1. It was tested for its specificity against 53 strains of Legionella recently isolated from the environment in Singapore and Malaysia. The specificity and sensitivity of this method of assay was confirmed, though there is some concern that the specificity was too narrow, and there are reservations about the criteria suggested for interpreting the results.
    Matched MeSH terms: Legionella/isolation & purification*
  3. Yong SF, Goh FN, Ngeow YF
    J Water Health, 2010 Mar;8(1):92-100.
    PMID: 20009251 DOI: 10.2166/wh.2009.002
    In this study, we investigated the distribution of Legionella species in water cooling towers located in different parts of Malaysia to obtain information that may inform public health policies for the prevention of legionellosis. A total of 20 water samples were collected from 11 cooling towers located in three different states in east, west and south Malaysia. The samples were concentrated by filtration and treated with an acid buffer before plating on to BCYE agar. Legionella viable counts in these samples ranged from 100 to 2,000 CFU ml(-1); 28 isolates from the 24 samples were examined by latex agglutination as well as 16S rRNA and rpoB PCR-DNA sequencing. These isolates were identified as Legionella pneumophila serogroup 1 (35.7%), L. pneumophila serogroup 2-14 (39%), L. pneumophila non-groupable (10.7%), L. busanensis, L. gormanii, L. anisa and L. gresilensis. L. pneumophila was clearly the predominant species at all sampling sites. Repeat sampling from the same cooling tower and testing different colonies from the same water sample showed concurrent colonization by different serogroups and different species of Legionella in some of the cooling towers.
    Matched MeSH terms: Legionella/isolation & purification*