Displaying all 6 publications

Abstract:
Sort:
  1. Khoo JJ
    Med J Malaysia, 2004 Mar;59(1):50-5.
    PMID: 15535336 MyJurnal
    A 4-year-review was carried out on intraoperative frozen section consultations in Sultanah Aminah Hospital, Johor Bahru. Two hundred and fifteen specimens were received from 79 patients in the period between January 1999 and December 2002. An average of 2.72 specimens per patient was received. The overall diagnostic accuracy was high, 97.56%. The diagnoses were deferred in 4.65% of the specimens. False positive diagnoses were made in 3 specimens (1.46%) and false negative diagnoses in 2 specimens (0.98%). This gave an error rate of 2.44%. The main cause of error was incorrect interpretation of the pathologic findings. In the present study, frozen sections showed good sensitivity (97.98%) and specificity (97.16%). Despite its limitations, frozen section is still generally considered to be an accurate mode of intraoperative consultation to assist the surgeon in deciding the best therapeutic approach for his patient at the operating table. The use of frozen section with proper indications was cost-effective as it helped lower the number of reoperations. An audit of intraoperative frozen section from time to time serves as part of an ongoing quality assurance program and should be recommended where the service is available.
    Matched MeSH terms: Medical Audit/methods*
  2. Ng KJ, Yii MK
    Med J Malaysia, 2003 Oct;58(4):516-21.
    PMID: 15190626
    Comparative surgical audit to monitor quality of care should be performed with a risk-adjusted scoring system rather than using crude morbidity and mortality rates. A validated and widely applied risk adjusted scoring system, P-POSSUM (Portsmouth-Physiological and Operative Severity Score for the enUmeration of Mortality) methodology, was applied to a prospective series of predominantly general surgical patients at the Sarawak General Hospital, Kuching over a six months period. The patients were grouped into four risk groups. The observed mortality rates were not significantly different from predicted rates, showing that the quality of surgical care was at par with typical western series. The simplicity and advantages of this scoring system over other auditing tools are discussed. The P-POSSUM methodology could form the basis of local comparative surgical audit for assessment and maintenance of quality care.
    Matched MeSH terms: Medical Audit/methods*
  3. Saokaew S, Sugimoto T, Kamae I, Pratoomsoot C, Chaiyakunapruk N
    PLoS One, 2015;10(11):e0141993.
    PMID: 26560127 DOI: 10.1371/journal.pone.0141993
    Health technology assessment (HTA) has been continuously used for value-based healthcare decisions over the last decade. Healthcare databases represent an important source of information for HTA, which has seen a surge in use in Western countries. Although HTA agencies have been established in Asia-Pacific region, application and understanding of healthcare databases for HTA is rather limited. Thus, we reviewed existing databases to assess their potential for HTA in Thailand where HTA has been used officially and Japan where HTA is going to be officially introduced.
    Matched MeSH terms: Medical Audit/methods
  4. Lim TO, Soraya A, Ding LM, Morad Z
    Int J Qual Health Care, 2002 Jun;14(3):251-8.
    PMID: 12108535
    Quality assurance of medical practice requires assessment of doctors' performance, whether informally via a system such as peer review or more formally via one such as credentialing. Current methods of assessment are, however, subjective or implicit. More objective methods of assessment based on statistical process control technique such as cumulative sum (CUSUM) procedure may be helpful.
    Matched MeSH terms: Medical Audit/methods*
  5. Rassiah P, Ng KH, DeWerd LA, Kunugi K
    Australas Phys Eng Sci Med, 2004 Mar;27(1):25-9.
    PMID: 15156705
    A thermoluminescent dosimetry (TLD) postal dose inter-comparison was carried out amongst radiotherapy centres in Malaysia. The aim of this TLD inter-comparison was to compare the uniformity involved in the measurement of absorbed dose among the participating centres. A set of 5 TLD chips placed within acrylic trays were mailed to all participating centres for irradiation to an absorbed dose to water of 2 Gy. Measurements were made for 6 MV and 60Co photon beams. Results show an agreement of +/- 5% for all but three radiotherapy centres. The ratios of the TLD readings to that of the reference centre are comparable with other national/regional dose inter-comparisons. The importance of a proper ongoing quality assurance program is essential in maintaining the consistency and uniformity of doses delivered.
    Matched MeSH terms: Medical Audit/methods
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links