Displaying all 8 publications

Abstract:
Sort:
  1. Waran V, Pancharatnam D, Thambinayagam HC, Raman R, Rathinam AK, Balakrishnan YK, et al.
    PMID: 23315670 DOI: 10.1055/s-0032-1330960
    Navigation in neurosurgery has expanded rapidly; however, suitable models to train end users to use the myriad software and hardware that come with these systems are lacking. Utilizing three-dimensional (3D) industrial rapid prototyping processes, we have been able to create models using actual computed tomography (CT) data from patients with pathology and use these models to simulate a variety of commonly performed neurosurgical procedures with navigation systems.
    Matched MeSH terms: Surgery, Computer-Assisted/methods*
  2. Che S, Ismail NH, Wang W, Awang RA
    Medicine (Baltimore), 2025 Mar 14;104(11):e41922.
    PMID: 40101046 DOI: 10.1097/MD.0000000000041922
    RATIONALE: This case series explores dynamic navigation systems (DNS) in transmandibular nerve canal implantation for patients with limited jaw space due to the proximity of the inferior alveolar nerve (IAN). The aim is to demonstrate how DNS improves implant placement precision and safety in cases where traditional methods face challenges.

    PATIENT CONCERNS: The patients had limited bone height and proximity to the IAN, making traditional implant techniques challenging. Concerns included the risk of nerve damage and difficulties in achieving optimal implant placement due to anatomical constraints.

    DIAGNOSES: Both patients had severe bone resorption and insufficient bone height in the posterior mandible, with concerns about IAN positioning. The first patient had grade III mobility in tooth #46 with a periapical infection, while the second had bilateral posterior mandibular pain and grade III mobility in tooth #47.

    INTERVENTIONS: Implants were placed using DNS, allowing precise planning and real-time guidance during surgery. Based on cone beam computed tomography, preoperative planning assessed bone height and IAN proximity. DNS ensured accurate implant placement, avoiding nerve interference, while bone grafts and growth factors were applied for healing.

    OUTCOMES: Both cases showed successful implant placement without complications like nerve damage or implant misplacement. Follow-up cone beam computed tomography scans confirmed well-positioned implants, with minimal bone resorption in the first case over 2 years and stable conditions in the second case after 6 months.

    LESSONS: This series highlights DNS's effectiveness in improving implant accuracy and reducing nerve injury risks, suggesting its value in complex dental implant surgeries.

    Matched MeSH terms: Surgery, Computer-Assisted/methods
  3. Abdullah BJ, Yeong CH, Goh KL, Yoong BK, Ho GF, Yim CC, et al.
    Eur Radiol, 2015 Jan;25(1):246-57.
    PMID: 25189152 DOI: 10.1007/s00330-014-3391-7
    OBJECTIVE: This study aimed to assess the technical success, radiation dose, safety and performance level of liver thermal ablation using a computed tomography (CT)-guided robotic positioning system.

    METHODS: Radiofrequency and microwave ablation of liver tumours were performed on 20 patients (40 lesions) with the assistance of a CT-guided robotic positioning system. The accuracy of probe placement, number of readjustments and total radiation dose to each patient were recorded. The performance level was evaluated on a five-point scale (5-1: excellent-poor). The radiation doses were compared against 30 patients with 48 lesions (control) treated without robotic assistance.

    RESULTS: Thermal ablation was successfully completed in 20 patients with 40 lesions and confirmed on multiphasic contrast-enhanced CT. No procedure related complications were noted in this study. The average number of needle readjustment was 0.8 ± 0.8. The total CT dose (DLP) for the entire robotic assisted thermal ablation was 1382 ± 536 mGy.cm, while the CT fluoroscopic dose (DLP) per lesion was 352 ± 228 mGy.cm. There was no statistically significant (p > 0.05) dose reduction found between the robotic-assisted versus the conventional method.

    CONCLUSION: This study revealed that robotic-assisted planning and needle placement appears to be safe, with high accuracy and a comparable radiation dose to patients.

    KEY POINTS: • Clinical experience on liver thermal ablation using CT-guided robotic system is reported. • The technical success, radiation dose, safety and performance level were assessed. • Thermal ablations were successfully performed, with an average performance score of 4.4/5.0. • Robotic-assisted ablation can potentially increase capabilities of less skilled interventional radiologists. • Cost-effectiveness needs to be proven in further studies.

    Matched MeSH terms: Surgery, Computer-Assisted/methods*
  4. Afzal MR, Daoud EG, Cunnane R, Mulpuru SK, Koay A, Hussain A, et al.
    Heart Rhythm, 2018 06;15(6):841-846.
    PMID: 29427820 DOI: 10.1016/j.hrthm.2018.02.008
    BACKGROUND: Experience with retrieval of the Micra transcatheter pacing system (TPS) is limited because of its relatively newer technology. Although abandonment of the TPS at end of life is recommended, certain situations such as endovascular infection or device embolization warrant retrieval.

    OBJECTIVE: The purpose of this study was to report the worldwide experience with successful retrieval of the Micra TPS.

    METHODS: A list of all successful retrievals of the currently available leadless pacemakers (LPs) was obtained from the manufacturer of Micra TPS. Pertinent details of retrieval, such as indication, days postimplantation, equipment used, complications, and postretrieval management, were obtained from the database collected by the manufacturer. Other procedural details were obtained directly from the operators at each participating site.

    RESULTS: Data from the manufacturer consisted of 40 successful retrievals of the Micra TPS. Operators for 29 retrievals (73%) provided the consent and procedural details. Of the 29 retrievals, 11 patients underwent retrieval during the initial procedure (immediate retrieval); the other 18 patients underwent retrieval during a separate procedure (delayed retrieval). Median duration before delayed retrieval was 46 days (range 1-95 days). The most common reason for immediate retrieval was elevated pacing threshold after tether removal. The most common reasons for delayed retrieval included elevated pacing threshold at follow-up, endovascular infection, and need for transvenous device. Mean procedure duration was 63.11 ± 56 minutes. All retrievals involved snaring via a Micra TPS delivery catheter or steerable sheath. No serious complications occurred during the reported retrievals.

    CONCLUSION: Early retrieval of the Micra TPS is feasible and safe.

    Matched MeSH terms: Surgery, Computer-Assisted/methods*
  5. Tan BH, Sockalingam S, Ganesan D
    Br J Neurosurg, 2025 Apr;39(2):262-265.
    PMID: 37345453 DOI: 10.1080/02688697.2023.2225611
    OBJECTIVES: Posterior cervical foraminotomy is a surgical procedure used to treat unilateral cervical radiculopathy. It provides direct decompression of the nerve root without the necessity of fusion while maintaining cervical mobility. With the advancement in image-guidance technology and minimal access techniques, intra-operative CT has provided a safer, more accurate instrumentation placement with less radiation exposure to operative staff and provides better anatomical visualization quality compared to traditional intra-operative imaging techniques. This case series aims to address the applications of advanced image guidance in posterior cervical foraminotomy and describe the nuances.

    METHOD: A technical report on a series of seven cases on intraoperative CT navigation for posterior cervical foraminotomy surgery. Posterior cervical foraminotomy was performed in all patients under CT guided navigation system without an image intensifier. In one case after the foraminotomy, the extruded disc was carefully removed by gentle retraction.

    RESULT: From 1 January 2020 to 31 December 2021, a total of seven patients with nine cervical foraminotomy procedures were performed using the aid of CT-guided navigation. The series comprised five women and two men whose mean age was 50.6 years. In all cases, the radiculopathy symptoms were diminished significantly. There were no cases of instability on the dynamic cervical radiograph. There were no complications during the surgical procedure.

    CONCLUSION: The navigation also allows the surgeon to localise the index level accurately and appraise the adequacy of the intended decompression in three planes of the CT scan image. The ability to perform accurate spine navigation would be the precursor for robotic spinal surgery.

    Matched MeSH terms: Surgery, Computer-Assisted/methods
  6. Abdullah BJ, Yeong CH, Goh KL, Yoong BK, Ho GF, Yim CC, et al.
    Eur Radiol, 2014 Jan;24(1):79-85.
    PMID: 23928933 DOI: 10.1007/s00330-013-2979-7
    OBJECTIVE: Computed tomography (CT)-compatible robots, both commercial and research-based, have been developed with the intention of increasing the accuracy of needle placement and potentially improving the outcomes of therapies in addition to reducing clinical staff and patient exposure to radiation during CT fluoroscopy. In the case of highly inaccessible lesions that require multiple plane angulations, robotically assisted needles may improve biopsy access and targeted drug delivery therapy by avoidance of the straight line path of normal linear needles.

    METHODS: We report our preliminary experience of performing radiofrequency ablation of the liver using a robotic-assisted CT guidance system on 11 patients (17 lesions).

    RESULTS/CONCLUSION: Robotic-assisted planning and needle placement appears to have high accuracy, is technically easier than the non-robotic-assisted procedure, and involves a significantly lower radiation dose to both patient and support staff.

    KEY POINTS: • An early experience of robotic-assisted radiofrequency ablation is reported • Robotic-assisted RFA improves accuracy of hepatic lesion targeting • Robotic-assisted RFA makes the procedure technically easier with significant lower radiation dose.

    Matched MeSH terms: Surgery, Computer-Assisted/methods*
  7. Habib MA, Ibrahim F, Mohktar MS, Kamaruzzaman SB, Rahmat K, Lim KS
    World Neurosurg, 2016 Apr;88:576-585.
    PMID: 26548833 DOI: 10.1016/j.wneu.2015.10.096
    BACKGROUND: Electroencephalography source imaging (ESI) is a promising tool for localizing the cortical sources of both ictal and interictal epileptic activities. Many studies have shown the clinical usefulness of interictal ESI, but very few have investigated the utility of ictal ESI. The aim of this article is to examine the clinical usefulness of ictal ESI for epileptic focus localization in patients with refractory focal epilepsy, especially extratemporal lobe epilepsy.

    METHODS: Both ictal and interictal ESI were performed by the use of patient-specific realistic forward models and 3 different linear distributed inverse models. Lateralization as well as concordance between ESI-estimated focuses and single-photon emission computed tomography (SPECT) focuses were assessed.

    RESULTS: All the ESI focuses (both ictal and interictal) were found lateralized to the same hemisphere as ictal SPECT focuses. Lateralization results also were in agreement with the lesion sides as visualized on magnetic resonance imaging. Ictal ESI results, obtained from the best-performing inverse model, were fully concordant with the same cortical lobe as SPECT focuses, whereas the corresponding concordance rate is 87.50% in case of interictal ESI.

    CONCLUSIONS: Our findings show that ictal ESI gives fully lateralized and highly concordant results with ictal SPECT and may provide a cost-effective substitute for ictal SPECT.

    Matched MeSH terms: Surgery, Computer-Assisted/methods*
  8. Waran V, Tang IP, Karuppiah R, Abd Kadir KA, Chandran H, Muthusamy KA, et al.
    Br J Neurosurg, 2013 Dec;27(6):742-6.
    PMID: 23647078 DOI: 10.3109/02688697.2013.791667
    Abstract The endoscopic transnasal, transsphenoidal surgical technique for pituitary tumour excision has generally been regarded as a less invasive technique, ranging from single nostril to dual nostril techniques. We propose a single nostril technique using a modified nasal speculum as a preferred technique. We initially reviewed 25 patients who underwent pituitary tumour excision, via endoscopic transnasal transsphenoidal surgery, using this new modified speculum-guided single nostril technique. The results show shorter operation time with reduced intra- and post-operative nasal soft tissue injuries and complications.
    Matched MeSH terms: Surgery, Computer-Assisted/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links