Affiliations 

  • 1 Faculty of Medicine, Medical Campus, Universiti Sultan Zainal Abidin, Jalan Sultan Mahmud, Kuala Terengganu 20400, Terengganu, Malaysia
  • 2 Faculty of Informatics and Computing, Besut Campus, Universiti Sultan Zainal Abidin, Besut 22200, Terengganu, Malaysia
  • 3 Infostructure & Network Management Center, Gong Badak Campus, Universiti Sultan Zainal Abidin, Kuala Nerus 21300, Terengganu, Malaysia
  • 4 University Institute of Public Health, Faculty of Allied Health Sciences, The University of Lahore, Lahore 54590, Pakistan
  • 5 Faculty of Health and Life Sciences, INTI International University, Nilai 71800, Negeri Sembilan, Malaysia
  • 6 Centre for Biomedical and Nutrition Research, Universiti Tunku Abdul Rahman, Jalan Universiti, Banda Barat, Kampar 31900, Perak, Malaysia
  • 7 Faculty of Dentistry, AIMST University, Bedong 08100, Kedah, Malaysia
Medicina (Kaunas), 2023 May 10;59(5).
PMID: 37241144 DOI: 10.3390/medicina59050912

Abstract

Background and Objectives: The health-related mobile applications (app) might assist in promoting inclusive health and tele-treatment, especially for the less severe diseases. In this paper, a study had been done to determine the app's reliability in terms of raters and the app's agreement with the Snellen chart. Materials and Methods: A cross-sectional sectional study was conducted between November 2019 and September 2020. Participants were selected via purposive sampling from selected communities in Terengganu state. All participants underwent vision testing with the Vis-Screen app and Snellen chart for validity and reliability accordingly. Results: A total of 408 participants were involved, with a mean age of 29.3. The sensitivity of the presenting vision of the right eye (PVR) ranged from 55.6% to 88.4%, with specificity between 94.7% to 99.3%, while the positive and negative predictive values were between 57.9% and 81.7% and 96.8% and 99.0%, respectively. The positive likelihood ratios ranged between 16.73 and 73.89, whereas the negative likelihood ratios ranged from 0.12 to 0.45. The area under the receiver operating characteristic curve (AUC) for all cut-off points ranged between 0.93 and 0.97, and the optimum cut-off point was at 6/12. The kappa values for intra-rater and inter-rater were 0.85 and 0.75, respectively, while the app's reliability with the Snellen chart was 0.61. Conclusions: Vis-Screen was concluded to be valid and reliable for use as a screening tool for detecting individuals with visual impairment and blindness in the community. A valid and reliable portable vision screener like Vis-Screen will help expand the eye care feasibility while providing similar accuracy as the conventional charts in clinical practices.

* Title and MeSH Headings from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.