Affiliations 

  • 1 1UKM Medical Molecular Biology Institute (UMBI), UKM Medical Center, Universiti Kebangsaan Malaysia, Malaysia
  • 2 Physical Activity and Energy Metabolism Research Group, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Malaysia. Email: pbkoon@ukm.edu.my
  • 3 UKM Medical Molecular Biology Institute (UMBI), UKM Medical Center, Universiti Kebangsaan Malaysia, Malaysia
  • 4 School of Hospitality, Tourism and Culinary Arts, Taylor’s University, Subang Jaya 47500, Malaysia
  • 5 UKM Medical Molecular Biology Institute (UMBI), UKM Medical Center, Universiti Kebangsaan Malaysia, Malaysia. Email: rahmanj@ppukm.ukm.edu.my
Int J Public Health Res, 2015;5(2):643-653.
MyJurnal

Abstract

Introduction: Validation of instruments is essential when assessing physical activity (PA). The aim of this study was to validate a Malay language version of the International Physical Activity Questionnaire (IPAQ-M) against Actical accelerometer and to determine its reliability and validity.
Methods: A total of 90 Malay adults aged 35-65 years old participating in The Malaysian Cohort project were recruited for this study. The IPAQ-M is comprised of 12 items, covering vigorous, moderate, walking, sitting and sleeping activities, and was administered on two occasions (Day 1 and Day 9) by interviewing the participants. Participants wore the Actical accelerometer for seven consecutive days between the two interview sessions. Results Validity tests showed that time spent in moderate-vigorous physical activity (MVPA) (min/wk) from IPAQ-M was significantly correlated with MVPA from accelerometer (rho=0.32, p<0.01). Time spent in vigorous activity (rho=0.44) and total activity (rho=0.36) from IPAQ-M were significantly correlated (p<0.01) with that measured by accelerometer, but no correlation was observed for sedentary behaviour. Reliability tests revealed significant correlations between the two interview sessions for all intensities of PA (rho=0.55 to 0.71, p<0.01). Bland-Altman plots showed that time spent in MVPA for IPAQ-M was significantly different from that measured by accelerometer (mean difference: 98.02 min/wk; 95% limits of agreement: -785.33 to 1317.83 min/wk; p<0.01). When classifying people into meeting PA recommendation, the agreement between the two instruments was fair (κ=0.22).
Conclusions The IPAQ-M has acceptable validity for MVPA, vigorous and total physical activity, and was reliable for assessing the physical activity of Malay adults.
Keywords Health care workers - Knowledge - Practice - Universal precaution - Health center.
Study name: The Malaysian Cohort (TMC) Project