Abstract

A single wall single image x-ray radiographic technique was adopted to investigate thickness variation of steel specimens caused by uniform corrosion. The ability of the 100 kV-160 kV x-rays to produce a meaningful film density for steel was also investigated. The thickness contour maps of corroded steel plates were found matching with the x-ray film density contour maps of the plates. The results confirm that x-ray radiography can be used to detect the thickness reduction of steel caused by uniform corrosion.
Bagi mengesan perubahan ketebalan keluli akibat kakisan seragam maka radiografi sinar-x teknik imej tunggal dinding tunggal telah digunakan. Kemampuan sinar-x 100 kV-160 kV menghasilkan ketumpatan filem yang sesuai untuk keluli telah juga dikaji. Peta kontur ketebalan bagi spesimen kepingan keluli yang telah mengalami kakisan seragam didapati sepadan dengan peta kontur ketumpatan filem radiografi sinar-x bagi spesimen tersebut. Kajian ini menunjukkan radiografi sinar-x boleh digunakan bagi mengesan penipisan keluli akibat kakisan seragam.