Displaying publications 1 - 20 of 42 in total

Abstract:
Sort:
  1. Ahamed NU, Ahmed N, Alqahtani M, Altwijri O, Ahmad RB, Sundaraj K
    J Phys Ther Sci, 2015 Jan;27(1):39-40.
    PMID: 25642033 DOI: 10.1589/jpts.27.39
    [Purpose] This study investigated the changes in the slope of EMG-time curves (relationship) at the maximal and different levels of dynamic (eccentric and concentric) and static (isometric) contractions. [Subjects and Methods] The subject was a 17 year-old male adolescent. The surface EMG signal of the dominant arm's biceps brachii (BB) was recorded through electrodes placed on the muscle belly. [Results] The results obtained during the contractions show that the regression slope was very close to 1.00 during concentric contraction, whereas those of eccentric and isometric contractions were lower. Significant differences were found for the EMG amplitude and time lags among the contractions. [Conclusion] The results show that the EMG signal of the BB varies among the three modes of contraction and the relationship of the EMG amplitude with a time lag gives the best fit during concentric contraction.
  2. Ahamed NU, Sundaraj K, Ahmad B, Rahman M, Ali MA, Islam MA
    Australas Phys Eng Sci Med, 2014 Mar;37(1):83-95.
    PMID: 24477560 DOI: 10.1007/s13246-014-0245-1
    Cricket bowling generates forces with torques on the upper limb muscles and makes the biceps brachii (BB) muscle vulnerable to overuse injury. The aim of this study was to investigate whether there are differences in the amplitude of the EMG signal of the BB muscle during fast and spin delivery, during the seven phases of both types of bowling and the kinesiological interpretation of the bowling arm for muscle contraction mechanisms during bowling. A group of 16 male amateur bowlers participated in this study, among them 8 fast bowlers (FB) and 8 spin bowlers (SB). The root mean square (EMGRMS), the average sEMG (EMGAVG), the maximum peak amplitude (EMGpeak), and the variability of the signal were calculated using the coefficient of variance (EMGCV) from the BB muscle of each bowler (FB and SB) during each bowling phase. The results demonstrate that, (i) the BB muscle is more active during FB than during SB, (ii) the point of ball release and follow-through generated higher signals than the other five movements during both bowling categories, (iii) the BB muscle variability is higher during SB compared with FB, (iv) four statistically significant differences (p<0.05) found between the bowling phases in fast bowling and three in spin bowling, and (v) several arm mechanics occurred for muscle contraction. There are possible clinical significances from the outcomes; like, recurring dynamic contractions on BB muscle can facilitate to clarify the maximum occurrence of shoulder pain as well as biceps tendonitis those are medically observed in professional cricket bowlers, and treatment methods with specific injury prevention programmes should focus on the different bowling phases with the maximum muscle effect. Finally, these considerations will be of particular importance in assessing different physical therapy on bowler's muscle which can improve the ball delivery performance and stability of cricket bowlers.
  3. Ahamed NU, Sundaraj K, Poo TS
    Proc Inst Mech Eng H, 2013 Mar;227(3):262-74.
    PMID: 23662342
    This article describes the design of a robust, inexpensive, easy-to-use, small, and portable online electromyography acquisition system for monitoring electromyography signals during rehabilitation. This single-channel (one-muscle) system was connected via the universal serial bus port to a programmable Windows operating system handheld tablet personal computer for storage and analysis of the data by the end user. The raw electromyography signals were amplified in order to convert them to an observable scale. The inherent noise of 50 Hz (Malaysia) from power lines electromagnetic interference was then eliminated using a single-hybrid IC notch filter. These signals were sampled by a signal processing module and converted into 24-bit digital data. An algorithm was developed and programmed to transmit the digital data to the computer, where it was reassembled and displayed in the computer using software. Finally, the following device was furnished with the graphical user interface to display the online muscle strength streaming signal in a handheld tablet personal computer. This battery-operated system was tested on the biceps brachii muscles of 20 healthy subjects, and the results were compared to those obtained with a commercial single-channel (one-muscle) electromyography acquisition system. The results obtained using the developed device when compared to those obtained from a commercially available physiological signal monitoring system for activities involving muscle contractions were found to be comparable (the comparison of various statistical parameters) between male and female subjects. In addition, the key advantage of this developed system over the conventional desktop personal computer-based acquisition systems is its portability due to the use of a tablet personal computer in which the results are accessible graphically as well as stored in text (comma-separated value) form.
  4. Ahamed NU, Sundaraj K, Alqahtani M, Altwijri O, Ali MA, Islam MA
    Technol Health Care, 2014 Oct 15.
    PMID: 25318958
    BACKGROUND: The relationship between surface electromyography (EMG) and force have been the subject of ongoing investigations and remain a subject of controversy. Even under static conditions, the relationships at different sensor placement locations in the biceps brachii (BB) muscle are complex.

    OBJECTIVE: The aim of this study was to compare the activity and relationship between surface EMG and static force from the BB muscle in terms of three sensor placement locations.

    METHODS: Twenty-one right hand dominant male subjects (age 25.3 ± 1.2 years) participated in the study. Surface EMG signals were detected from the subject's right BB muscle. The muscle activation during force was determined as the root mean square (RMS) electromyographic signal normalized to the peak RMS EMG signal of isometric contraction for 10 s. The statistical analysis included linear regression to examine the relationship between EMG amplitude and force of contraction [40-100% of maximal voluntary contraction (MVC)], repeated measures ANOVA to assess differences among the sensor placement locations, and coefficient of variation (CoV) for muscle activity variation.

    RESULTS: The results demonstrated that when the sensor was placed on the muscle belly, the linear slope coefficient was significantly greater for EMG versus force testing (r^{2} = 0.61, P > 0.05) than when placed on the lower part (r^{2}=0.31, P< 0.05) and upper part of the muscle belly (r^{2}=0.29, P > 0.05). In addition, the EMG signal activity on the muscle belly had less variability than the upper and lower parts (8.55% vs. 15.12% and 12.86%, respectively).

    CONCLUSION: These findings indicate the importance of applying the surface EMG sensor at the appropriate locations that follow muscle fiber orientation of the BB muscle during static contraction. As a result, EMG signals of three different placements may help to understand the difference in the amplitude of the signals due to placement.

  5. Ali A, Sundaraj K, Ahmad B, Ahamed N, Islam A
    Bosn J Basic Med Sci, 2012 Aug;12(3):193-202.
    PMID: 22938548
    Even though the amount of rehabilitation guidelines has never been greater, uncertainty continues to arise regarding the efficiency and effectiveness of the rehabilitation of gait disorders. This question has been hindered by the lack of information on accurate measurements of gait disorders. Thus, this article reviews the rehabilitation systems for gait disorder using vision and non-vision sensor technologies, as well as the combination of these. All papers published in the English language between 1990 and June, 2012 that had the phrases "gait disorder", "rehabilitation", "vision sensor", or "non vision sensor" in the title, abstract, or keywords were identified from the SpringerLink, ELSEVIER, PubMed, and IEEE databases. Some synonyms of these phrases and the logical words "and", "or", and "not" were also used in the article searching procedure. Out of the 91 published articles found, this review identified 84 articles that described the rehabilitation of gait disorders using different types of sensor technologies. This literature set presented strong evidence for the development of rehabilitation systems using a markerless vision-based sensor technology. We therefore believe that the information contained in this review paper will assist the progress of the development of rehabilitation systems for human gait disorders.
  6. Ali A, Sundaraj K, Badlishah Ahmad R, Ahamed NU, Islam A, Sundaraj S
    J Hum Kinet, 2015 Jun 27;46:69-76.
    PMID: 26240650 DOI: 10.1515/hukin-2015-0035
    The objective of the present study was to investigate the time to fatigue and compare the fatiguing condition among the three heads of the triceps brachii muscle using surface electromyography during an isometric contraction of a controlled forceful hand grip task with full elbow extension. Eighteen healthy subjects concurrently performed a single 90 s isometric contraction of a controlled forceful hand grip task and full elbow extension. Surface electromyographic signals from the lateral, long and medial heads of the triceps brachii muscle were recorded during the task for each subject. The changes in muscle activity among the three heads of triceps brachii were measured by the root mean square values for every 5 s period throughout the total contraction period. The root mean square values were then analysed to determine the fatiguing condition for the heads of triceps brachii muscle. Muscle fatigue in the long, lateral, and medial heads of the triceps brachii started at 40 s, 50 s, and 65 s during the prolonged contraction, respectively. The highest fatiguing rate was observed in the long head (slope = -2.863), followed by the medial head (slope = -2.412) and the lateral head (slope = -1.877) of the triceps brachii muscle. The results of the present study concurs with previous findings that the three heads of the triceps brachii muscle do not work as a single unit, and the fiber type/composition is different among the three heads.
  7. Ali MA, Sundaraj K, Ahmad RB, Ahamed NU, Islam MA, Sundaraj S
    Technol Health Care, 2014;22(4):617-25.
    PMID: 24990168 DOI: 10.3233/THC-140833
    Normally, surface electromyography electrodes are used to evaluate the activity of superficial muscles during various kinds of voluntary contractions of muscle fiber. The objective of the present study was to investigate the effect of repetitive isometric contractions on the three heads of the triceps brachii muscle during handgrip force exercise.
  8. Fung SK, Sundaraj K, Ahamed NU, Kiang LC, Nadarajah S, Sahayadhas A, et al.
    J Bodyw Mov Ther, 2014 Apr;18(2):220-7.
    PMID: 24725790 DOI: 10.1016/j.jbmt.2013.05.011
    Sports video tracking is a research topic that has attained increasing attention due to its high commercial potential. A number of sports, including tennis, soccer, gymnastics, running, golf, badminton and cricket have been utilised to display the novel ideas in sports motion tracking. The main challenge associated with this research concerns the extraction of a highly complex articulated motion from a video scene. Our research focuses on the development of a markerless human motion tracking system that tracks the major body parts of an athlete straight from a sports broadcast video. We proposed a hybrid tracking method, which consists of a combination of three algorithms (pyramidal Lucas-Kanade optical flow (LK), normalised correlation-based template matching and background subtraction), to track the golfer's head, body, hands, shoulders, knees and feet during a full swing. We then match, track and map the results onto a 2D articulated human stick model to represent the pose of the golfer over time. Our work was tested using two video broadcasts of a golfer, and we obtained satisfactory results. The current outcomes of this research can play an important role in enhancing the performance of a golfer, provide vital information to sports medicine practitioners by providing technically sound guidance on movements and should assist to diminish the risk of golfing injuries.
  9. Hussain J, Sundaraj K, Subramaniam ID, Lam CK
    J Musculoskelet Neuronal Interact, 2019 09 01;19(3):276-285.
    PMID: 31475934
    OBJECTIVE: The objective of this study was to investigate fatigue in the three heads of the triceps brachii (TB) muscle using surface electromyography (sEMG) obtained at 30%, 45% and 60% of maximal voluntary contraction (MVC).

    METHODS: Twenty-five subjects performed isometric elbow extension until failure, and the rate of fatigue (ROF), time to fatigue (TTF) and normalized TTF (NTTF) were statistically analysed. Subsequently, the behaviour of root-mean-square (RMS), mean-power frequency (MPF) and median-power frequency (MDF) under pre-, onset- and post-fatigue conditions were compared.

    RESULTS: The findings indicated that, among the heads, ROF was statistically significant at 30% and 45% MVC (P<0.05) but TTF and NTTF at all intensities was statistically insignificant (P>0.05). For every head, only TTF was statistically significant (P<0.05) at different intensities. MPF and MDF under pre-, onset- and post-fatigue conditions were statistically significant (P<0.05) among the heads at all intensities, whereas RMS showed no such behaviour.

    CONCLUSION: The investigated parameters reveal that the three heads of TB act independently before fatigue onset and appear to work in union after fatigue. Synergist head pairs exhibit similar spectral and temporal behaviour in contrast to the non-synergist TB head pair. We find spectral parameters to be more specific predictors of fatigue.

  10. Hussain J, Sundaraj K, Subramaniam ID, Lam CK
    Front Physiol, 2020;11:112.
    PMID: 32153422 DOI: 10.3389/fphys.2020.00112
    The objective of this study was to investigate the effects of changes in exercise intensity and speed on the three heads of the triceps brachii (TB) during triceps push-down exercise until task failure. Twenty-five subjects performed triceps push-down exercise at three different intensities (30, 45, and 60% 1RM) and speeds (slow, medium, and fast) until failure, and surface electromyography (sEMG) signals were recorded from the lateral, long and medial heads of the TB. The endurance time (ET), number of repetitions (NR) and rate of fatigue (ROF) were analyzed. Subsequently, the root-mean-square (RMS), mean power frequency (MPF) and median frequency (MDF) under no-fatigue (NF) and fatigue (Fa) conditions were statistically compared. The findings reveal that ROF increases with increase in the intensity and speed, and the opposite were obtained for the ET. The ROF in the three heads were comparable for all intensities and speeds. The ROF showed a significant difference (P < 0.05) among the three intensities and speeds for all heads. The three heads showed significantly different (P < 0.05) MPF and MDF values for all the performed exercises under both conditions, whereas the RMS values were significantly different only under Fa conditions. The current observations suggest that exercise intensity and speed affect the ROF while changes in intensity do not affect the MPF and MDF under Fa conditions. The behavior of the spectral parameters indicate that the three heads do not work in unison under any of the conditions. Changes in the speed of triceps push-down exercise affects the lateral and long heads, but changes in the exercise intensity affected the attributes of all heads to a greater extent.
  11. Hussain J, Sundaraj K, Subramaniam ID
    PLoS One, 2020;15(1):e0228089.
    PMID: 31999750 DOI: 10.1371/journal.pone.0228089
    INTRODUCTION: Cognitive stress (CS) changes the peripheral attributes of a muscle, but its effect on multi-head muscles has not been investigated. The objective of the current research was to investigate the impact of CS on the three heads of the triceps brachii (TB) muscle.

    METHODS: Twenty-five young and healthy university students performed a triceps push-down exercise at 45% one repetition maximum (1RM) with and without CS until task failure, and the rate of fatigue (ROF), endurance time (ET) and number of repetitions (NR) for both exercises were analyzed. In addition, the first and last six repetitions of each exercise were considered non-fatiguing (NF) and fatiguing (Fa), respectively, and the root mean square (RMS), mean power frequency (MPF) and median frequency (MDF) for each exercise repetition were evaluated.

    RESULTS: The lateral and long head showed significant differences (P<0.05) in the ROF between the two exercises, and all the heads showed significant (P<0.05) differences in the RMS between the two exercises under NF conditions. Only the long head showed a significant difference (P<0.05) in the MPF and MDF between the two exercises. CS increases the ET (24.74%) and NR (27%) of the exercise. The three heads showed significant differences (P<0.05) in the RMS, MPF and MDF under all exercise conditions.

    CONCLUSION: A lower ROF was obtained with CS. In addition, the RMS was found to be better approximator of CS, whereas MPF and MDF were more resistant to the effect of CS. The results showed that the three heads worked independently under all conditions, and the non-synergist and synergist head pairs showed similar behavior under Fa conditions. The findings from this study provide additional insights regarding the functioning of each TB head.

  12. Islam A, Sundaraj K, Ahmad RB, Sundaraj S, Ahamed NU, Ali MA
    Muscle Nerve, 2015 Jun;51(6):899-906.
    PMID: 25204740 DOI: 10.1002/mus.24454
    In this study, we analyzed the crosstalk in mechanomyographic (MMG) signals generated by the extensor digitorum (ED), extensor carpi ulnaris (ECU), and flexor carpi ulnaris (FCU) muscles of the forearm during wrist flexion (WF) and extension (WE) and radial (RD) and ulnar (UD) deviations.
  13. Islam MA, Sundaraj K, Ahmad RB, Sundaraj S, Ahamed NU, Ali MA
    PLoS One, 2014;9(8):e104280.
    PMID: 25090008 DOI: 10.1371/journal.pone.0104280
    In mechanomyography (MMG), crosstalk refers to the contamination of the signal from the muscle of interest by the signal from another muscle or muscle group that is in close proximity.
  14. Islam MA, Sundaraj K, Ahmad RB, Sundaraj S, Ahamed NU, Ali MA
    PLoS One, 2014;9(5):e96628.
    PMID: 24802858 DOI: 10.1371/journal.pone.0096628
    This study aimed: i) to examine the relationship between the magnitude of cross-talk in mechanomyographic (MMG) signals generated by the extensor digitorum (ED), extensor carpi ulnaris (ECU), and flexor carpi ulnaris (FCU) muscles with the sub-maximal to maximal isometric grip force, and with the anthropometric parameters of the forearm, and ii) to quantify the distribution of the cross-talk in the MMG signal to determine if it appears due to the signal component of intramuscular pressure waves produced by the muscle fibers geometrical changes or due to the limb tremor.
  15. Islam MA, Sundaraj K, Ahmad RB, Ahamed NU
    PLoS One, 2013;8(3):e58902.
    PMID: 23536834 DOI: 10.1371/journal.pone.0058902
    BACKGROUND: Mechanomyography (MMG) has been extensively applied in clinical and experimental practice to examine muscle characteristics including muscle function (MF), prosthesis and/or switch control, signal processing, physiological exercise, and medical rehabilitation. Despite several existing MMG studies of MF, there has not yet been a review of these. This study aimed to determine the current status on the use of MMG in measuring the conditions of MFs.

    METHODOLOGY/PRINCIPAL FINDINGS: Five electronic databases were extensively searched for potentially eligible studies published between 2003 and 2012. Two authors independently assessed selected articles using an MS-Word based form created for this review. Several domains (name of muscle, study type, sensor type, subject's types, muscle contraction, measured parameters, frequency range, hardware and software, signal processing and statistical analysis, results, applications, authors' conclusions and recommendations for future work) were extracted for further analysis. From a total of 2184 citations 119 were selected for full-text evaluation and 36 studies of MFs were identified. The systematic results find sufficient evidence that MMG may be used for assessing muscle fatigue, strength, and balance. This review also provides reason to believe that MMG may be used to examine muscle actions during movements and for monitoring muscle activities under various types of exercise paradigms.

    CONCLUSIONS/SIGNIFICANCE: Overall judging from the increasing number of articles in recent years, this review reports sufficient evidence that MMG is increasingly being used in different aspects of MF. Thus, MMG may be applied as a useful tool to examine diverse conditions of muscle activity. However, the existing studies which examined MMG for MFs were confined to a small sample size of healthy population. Therefore, future work is needed to investigate MMG, in examining MFs between a sufficient number of healthy subjects and neuromuscular patients.

  16. Lam CK, Sundaraj K, Sulaiman MN
    Medicina (Kaunas), 2013;49(1):1-8.
    PMID: 23652710
    The aim of this study was to review the capability of virtual reality simulators in the application of phacoemulsification cataract surgery training. Our review included the scientific publications on cataract surgery simulators that had been developed by different groups of researchers along with commercialized surgical training products, such as EYESI® and PhacoVision®. The review covers the simulation of the main cataract surgery procedures, i.e., corneal incision, capsulorrhexis, phacosculpting, and intraocular lens implantation in various virtual reality surgery simulators. Haptics realism and visual realism of the procedures are the main elements in imitating the actual surgical environment. The involvement of ophthalmology in research on virtual reality since the early 1990s has made a great impact on the development of surgical simulators. Most of the latest cataract surgery training systems are able to offer high fidelity in visual feedback and haptics feedback, but visual realism, such as the rotational movements of an eyeball with response to the force applied by surgical instruments, is still lacking in some of them. The assessment of the surgical tasks carried out on the simulators showed a significant difference in the performance before and after the training.
  17. Lam CK, Sundaraj K, Sulaiman MN, Qamarruddin FA
    BMC Ophthalmol, 2016;16:88.
    PMID: 27296449 DOI: 10.1186/s12886-016-0269-2
    Computer based surgical training is believed to be capable of providing a controlled virtual environment for medical professionals to conduct standardized training or new experimental procedures on virtual human body parts, which are generated and visualised three-dimensionally on a digital display unit. The main objective of this study was to conduct virtual phacoemulsification cataract surgery to compare performance by users with different proficiency on a virtual reality platform equipped with a visual guidance system and a set of performance parameters.
  18. Mohamad Ismail MR, Lam CK, Sundaraj K, Rahiman MHF
    J Musculoskelet Neuronal Interact, 2021 12 01;21(4):481-494.
    PMID: 34854387
    OBJECTIVE: This paper presents the analyses of the fatigue effect on the cross-talk in mechanomyography (MMG) signals of extensor and flexor forearm muscles during pre- and post-fatigue maximum voluntary isometric contraction (MVIC).

    METHODS: Twenty male participants performed repetitive submaximal (60% MVIC) grip muscle contractions to induce muscle fatigue and the results were analyzed during the pre- and post-fatigue MVIC. MMG signals were recorded on the extensor digitorum (ED), extensor carpi radialis longus (ECRL), flexor digitorum superficialis (FDS) and flexor carpi radialis (FCR) muscles. The cross-correlation coefficient was used to quantify the cross-talk values in forearm muscle pairs (MP1, MP2, MP3, MP4, MP5 and MP6). In addition, the MMG RMS and MMG MPF were calculated to determine force production and muscle fatigue level, respectively.

    RESULTS: The fatigue effect significantly increased the cross-talk values in forearm muscle pairs except for MP2 and MP6. While the MMG RMS and MMG MPF significantly decreased (p<0.05) based on the examination of the mean differences from pre- and post-fatigue MVIC.

    CONCLUSION: The presented results can be used as a reference for further investigation of cross-talk on the fatigue assessment of extensor and flexor muscles' mechanic.

  19. Nabi FG, Sundaraj K, Lam CK
    J Pak Med Assoc, 2021 Jan;71(1(A)):41-46.
    PMID: 33484516 DOI: 10.47391/JPMA.156
    OBJECTIVE: Breath sound has information about underlying pathology and condition of subjects. The purpose of this study was to examine asthmatic acuteness levels (Mild, Moderate, Severe) using frequency features extracted from wheeze sounds. Further, analysis was extended to observe behaviour of wheeze sounds in different datasets.

    METHODS: Segmented and validated wheeze sounds was collected from 55 asthmatic patients from the trachea and lower lung base (LLB) during tidal breathing maneuvers. Segmented wheeze sounds have been grouped in to nine datasets based on auscultation location, breath phases and a combination of phase and location. Frequency based features F25, F50, F75, F90, F99 and mean frequency (MF) were calculated from normalized power spectrum. Subsequently, multivariate analysis was performed.

    RESULTS: Generally frequency features observe statistical significance (p < 0.05) for the majority of datasets to differentiate severity level Ʌ = 0.432-0.939, F(12, 196-1534) = 2.731-11.196, p < 0.05, ɳ2 = 0.061-0.568. It was observed that selected features performed better (higher effect size) for trachea related samples Ʌ = 0.432-0.620, F(12, 196-498) = 6.575-11.196, p < 0.05, ɳ2 = 0.386-0.568.

    CONCLUSIONS: The results demonstrated dthat severity levels of asthmatic patients with tidal breathing can be identified through computerized wheeze sound analysis. In general, auscultation location and breath phases produce wheeze sounds with different characteristics.

  20. Nabi FG, Sundaraj K, Lam CK, Palaniappan R
    Comput Biol Med, 2019 01;104:52-61.
    PMID: 30439599 DOI: 10.1016/j.compbiomed.2018.10.035
    OBJECTIVE: This study aimed to investigate and classify wheeze sounds of asthmatic patients according to their severity level (mild, moderate and severe) using spectral integrated (SI) features.

    METHOD: Segmented and validated wheeze sounds were obtained from auscultation recordings of the trachea and lower lung base of 55 asthmatic patients during tidal breathing manoeuvres. The segments were multi-labelled into 9 groups based on the auscultation location and/or breath phases. Bandwidths were selected based on the physiology, and a corresponding SI feature was computed for each segment. Univariate and multivariate statistical analyses were then performed to investigate the discriminatory behaviour of the features with respect to the severity levels in the various groups. The asthmatic severity levels in the groups were then classified using the ensemble (ENS), support vector machine (SVM) and k-nearest neighbour (KNN) methods.

    RESULTS AND CONCLUSION: All statistical comparisons exhibited a significant difference (p 

Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links