Displaying publications 1 - 20 of 36 in total

Abstract:
Sort:
  1. Bonaventura K, Schwefer M, Yusof AKM, Waliszewski M, Krackhardt F, Steen P, et al.
    Adv Ther, 2020 05;37(5):2210-2223.
    PMID: 32274746 DOI: 10.1007/s12325-020-01320-2
    INTRODUCTION: Scoring balloon angioplasty (SBA) for lumen gain prior to stent implantations or drug-coated balloon angioplasty (DCB) is considered an essential interventional tool for lesion preparation. Recent evidence indicates that SBA may play a pivotal role in enhancing the angiographic and clinical outcomes of DCB angioplasty.

    METHODS: We studied the systematic use of SBA with a low profile, non-slip element device prior to DCB angioplasty in an unselected, non-randomized patient population. This prospective, all-comers study enrolled patients with de novo lesions as well as in-stent restenotic lesions in bare metal stents (BMS-ISR) and drug-eluting stents (DES-ISR). The primary endpoint was the target lesion failure (TLF) rate at 9 months (ClinicalTrials.gov Identifier NCT02554292).

    RESULTS: A total of 481 patients (496 lesions) were recruited to treat de novo lesions (78.4%, 377), BMS-ISR (4.0%, 19), and DES-ISR (17.6%, 85). Overall risk factors were acute coronary syndrome (ACS, 20.6%, 99), diabetes mellitus (46.8%, 225), and atrial fibrillation (8.5%, 41). Average lesion lengths were 16.7 ± 10.4 mm in the de novo group, and 20.1 ± 8.9 mm (BMS-ISR) and 16.2 ± 9.8 mm (DES-ISR) in the ISR groups. Scoring balloon diameters were 2.43 ± 0.41 mm (de novo), 2.71 ± 0.31 mm (BMS-ISR), and 2.92 ± 0.42 mm (DES-ISR) whereas DCB diameters were 2.60 ± 0.39 mm (de novo), 3.00 ± 0.35 mm (BMS-ISR), and 3.10 ± 0.43 mm (DES-ISR), respectively. The overall accumulated TLF rate of 3.0% (14/463) was driven by significantly higher target lesion revascularization rates in the BMS-ISR (5.3%, 1/19) and the DES-ISR group (6.0%, 5/84). In de novo lesions, the TLF rate was 1.1% (4/360) without differences between calcified and non-calcified lesions (p = 0.158) and small vs. large reference vessel diameters with a cutoff value of 3.0 mm (p = 0.901).

    CONCLUSIONS: The routine use of a non-slip element scoring balloon catheter to prepare lesions suitable for drug-coated balloon angioplasty is associated with high procedural success rates and low TLF rates in de novo lesions.

    Matched MeSH terms: Angioplasty, Balloon, Coronary/instrumentation*; Angioplasty, Balloon, Coronary/methods*; Angioplasty, Balloon, Coronary/standards*
  2. Zuhdi AS, Mariapun J, Mohd Hairi NN, Wan Ahmad WA, Abidin IZ, Undok AW, et al.
    Ann Saudi Med, 2014 1 15;33(6):572-8.
    PMID: 24413861 DOI: 10.5144/0256-4947.2013.572
    BACKGROUND AND OBJECTIVES: Understanding the nature and pattern of young coronary artery disease (CAD) is important due to the tremendous impact on these patients' socio-economic and physical aspect. Data on young CAD in the southeast Asian region is rather patchy and limited. Hence we utilized our National Cardiovascular Disease Database (NCVD)-Percutaneous Coronary Intervention (PCI) Registry to analyze young patients who underwent PCI in the year 2007 to 2009.

    DESIGN AND SETTINGS: This is a retrospective study of all patients who had undergone coronary angioplasty from 2007 to 2009 in 11 hospitals across Malaysia.

    METHODS: Data were obtained from the NCVD-PCI Registry, 2007 to 2009. Patients were categorized into 2 groups-young and old, where young was defined as less than 45 years for men and less than 55 years for women and old was defined as more than or equals to 45 years for men and more than or equals to 55 years for women. Patients' baseline characteristics, risk factor profile, extent of coronary disease and outcome on dis.charge, and 30-day and 1-year follow-up were compared between the 2 groups.

    RESULTS: We analyzed 10268 patients, and the prevalence of young CAD was 16% (1595 patients). There was a significantly low prevalence of Chinese patients compared to other major ethnic groups. Active smoking (30.2% vs 17.7%) and obesity (20.9% vs 17.3%) were the 2 risk factors more associated with young CAD. There is a preponderance toward single vessel disease in the young CAD group, and they had a favorable clinical outcome in terms of all-cause mortality at discharge (RR 0.49 [CI 0.26-0.94]) and 1-year follow-up (RR 0.47 [CI 0.19-1.15]).

    CONCLUSION: We observed distinctive features of young CAD that would serve as a framework in the primary and secondary prevention of the early onset CAD.

    Matched MeSH terms: Angioplasty, Balloon, Coronary/methods*
  3. Shin ES, Bang LH, Jun EJ, Her AY, Chung JH, Garg S, et al.
    Cardiol J, 2021;28(4):615-622.
    PMID: 32789835 DOI: 10.5603/CJ.a2020.0105
    Although drug-eluting stents (DES) have become the mainstay of percutaneous coronary intervention, late and very late stent thrombosis remains a concern. Drug-coated balloons (DCB) have the advantage of preserving the anti-restenotic benefits of DES while minimizing potential long-term safety concerns. Currently the two methods to ensure successful DCB treatment of a stenotic lesion are angiography or physiology-guided DCB application. This review will evaluate these two methods based on previous evidence and make suggestions on how to perform DCB treatment more efficiently and safely.
    Matched MeSH terms: Angioplasty, Balloon, Coronary*
  4. Campos CM, Caixeta A, Franken M, Bartorelli AL, Whitbourn RJ, Wu CJ, et al.
    Catheter Cardiovasc Interv, 2018 02 15;91(3):387-395.
    PMID: 28471086 DOI: 10.1002/ccd.27109
    OBJECTIVES: to compare the occurrence of clinical events in diabetics treated with the Absorb bioresorbable vascular scaffold (Absorb BVS; Abbott Vascular, Santa Clara, CA) versus everolimus-eluting metal stents (EES; XIENCE V; Abbott Vascular, Santa Clara, CA) BACKGROUND: There are limited data dedicated to clinical outcomes of diabetic patients treated with bioresorbable scaffolds (BRS) at 2-year horizon.

    METHODS: The present study included 812 patients in the ABSORB EXTEND study in which a total of 215 diabetic patients were treated with Absorb BVS. In addition, 882 diabetic patients treated with EES in pooled data from the SPIRIT clinical program (SPIRIT II, SPIRIT III and SPIRIT IV trials) were used for comparison by applying propensity score matching using 29 different variables. The primary endpoint was ischemia driven major adverse cardiac events (ID-MACE), including cardiac death, myocardial infarction (MI), and ischemia driven target lesion revascularization (ID-TLR).

    RESULTS: After 2 years, the ID-MACE rate was 6.5% in the Absorb BVS vs. 8.9% in the Xience group (P = 0.40). There was no difference for MACE components or definite/probable device thrombosis (HR: 1.43 [0.24,8.58]; P = 0.69). The occurrence of MACE was not different for both diabetic status (insulin- and non-insulin-requiring diabetes) in all time points up to the 2-year follow-up for the Absorb and Xience groups.

    CONCLUSION: In this largest ever patient-level pooled comparison on the treatment of diabetic patients with BRS out to two years, individuals with diabetes treated with the Absorb BVS had a similar rate of MACE as compared with diabetics treated with the Xience EES. © 2017 Wiley Periodicals, Inc.

    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects; Angioplasty, Balloon, Coronary/instrumentation*; Angioplasty, Balloon, Coronary/mortality
  5. Rosenberg M, Waliszewski M, Chin K, Ahmad WAW, Caramanno G, Milazzo D, et al.
    Catheter Cardiovasc Interv, 2019 02 01;93(2):181-188.
    PMID: 30280482 DOI: 10.1002/ccd.27724
    OBJECTIVES: This prospective, observational all-comers registry assessed the safety and efficacy of a Drug Coated Balloon-only strategy (DCB-only) in patients with coronary lesions.

    BACKGROUND: Data regarding the performance of a DCB-only approach, especially in patients with previously untreated de-novo coronary artery disease (CAD), are still limited.

    METHODS: This study was conducted as an international, multicenter registry primarily enrolling patients with de-novo CAD. However, it was also possible to include patients with in-stent restenosis (ISR). The primary endpoint was the rate of clinically driven target lesion revascularization (TLR) after 9 months.

    RESULTS: A total of 1,025 patients with a mean age of 64.0 ± 11.2 years were enrolled. The majority of treated lesions were de-novo (66.9%), followed by drug-eluting-stent ISR (DES-ISR; 22.6%) and bare-metal-stent ISR (BMS-ISR; 10.5%). The TLR rate was lower in the de-novo group (2.3%) when compared to BMS- (2.9%) and DES-ISR (5.8%) (P = 0.049). Regarding MACE, there was a trend toward fewer events in the de-novo group (5.6%) than in the BMS- (7.8%) and DES-ISR cohort (9.6%) (P = 0.131). Subgroup analyses revealed that lesion type (95% CI 1.127-6.587); P = 0.026) and additional stent implantation (95% CI 0.054-0.464; P = 0.001) were associated with higher TLR rates.

    CONCLUSIONS: Our results show that DCB-only angioplasty of de-novo coronary lesions is associated with low MACE and TLR rates. Thus, DCBs appear to be an attractive alternative for the interventional, stentless treatment of suitable de-novo coronary lesions.

    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects; Angioplasty, Balloon, Coronary/instrumentation*
  6. Choo GH, Le D, Nguyen K, Phan H, Nguyen Q, Nguyen J
    Chin Med J (Engl), 2012 Oct;125(19):3565-8.
    PMID: 23044325
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  7. Lee ZV, Arjan Singh RS
    Cureus, 2021 Jan 07;13(1):e12542.
    PMID: 33425567 DOI: 10.7759/cureus.12542
    Transient cortical blindness after coronary angiography has long been reported in the literature; however, this condition remains rare until today. We report a case of transient cortical blindness after coronary angiography, bypass graft angiography, and coronary angioplasty, which was deemed to be secondary to contrast agent. A 60-year-old man who underwent prior coronary artery bypass grafting (CABG) started to experience recurrence of exertional and resting chest pain one year after CABG. In addition to coronary artery disease, he has underlying type 2 diabetes mellitus, hypertension, and dyslipidemia. Due to technical reasons, he was unable to undergo a computed tomography (CT) angiography of the coronary arteries and bypass grafts. Invasive coronary and bypass graft angiography were done, followed by stenting of the left circumflex artery. Thirty minutes after completion of the procedure, the patient had bilateral blurring of vision, which worsened drastically to only being able to perceive light bilaterally. The patient otherwise did not have any other neurological deficits. Binocular indirect ophthalmoscopy revealed no significant abnormalities apart from mild non-proliferative diabetic retinopathy of the left eye. A non-contrasted CT scan of the brain revealed acute subarachnoid bleed in both occipital lobes, but a subsequent magnetic resonance imaging scan of the brain revealed no evidence of intracranial bleed. The patient's vision gradually improved eight hours after the index event, and his vision completely normalized 12 hours later. The patient was discharged well two days later, and at one-month, three-month, and six-month follow-up, the patient remained angina-free, and his vision had remained stable bilaterally.
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  8. Ali RM, Degenhardt R, Zambahari R, Tresukosol D, Ahmad WA, Kamar Hb, et al.
    EuroIntervention, 2011 May;7 Suppl K:K83-92.
    PMID: 22027736 DOI: 10.4244/EIJV7SKA15
    Coronary lesions in diabetics (DM) are associated with a high recurrence following percutaneous coronary intervention (PCI), even after drug-eluting stent (DES) deployment. Encouraging clinical data of the drug-eluting balloon catheter (DEB) SeQuent Please warrant its investigation in these patients.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects; Angioplasty, Balloon, Coronary/instrumentation*; Angioplasty, Balloon, Coronary/mortality
  9. Chin K
    EuroIntervention, 2011 May;7 Suppl K:K43-6.
    PMID: 22027726 DOI: 10.4244/EIJV7SKA7
    In-stent restenosis remains an important issue even in the drug-eluting stent (DES) era today. In recent years, drug-eluting balloons (DEB) have emerged as a potential alternative to the treatment of in-stent restenosis. Paclitaxel was identified as the primary drug for DEB because of its rapid uptake and prolonged retention. Non-stent-based local drug delivery using DEB maintains the antiproliferation properties of DES, but without the limitations of DES such as subacute stent thrombosis, stent fractures, prolonged antiplatelet therapy and more importantly, avoiding a "stent-in-a-stent" approach. The first major impact of drug-eluting balloon (DEB) in the management of bare metal instent restenosis was the "PACCOCATH ISR I" randomised trial, comparing the efficacy of drug-eluting balloon versus uncoated balloon. The six months angiographic results showed a binary restenosis of 5% and 4% MACE in the drug-eluting balloon group, compared with 43% binary restenosis and 31% MACE, in the uncoated balloon group (p=0.002 and 0.02). The second major DEB trial is the "PEPCAD II Trial", comparing the efficacy of the SeQuent Please DEB with the Taxus drug-eluting stent in the treatment of bare-metal stent instent restenosis. At 6-month follow-up, in-segment late lumen loss was 0.38 ± 0.61 mm in the DES group versus 0.17 ± 0.42 mm (p=0.03) in the DEB group, resulting in a binary restenosis rate of 12/59 (20%) versus 4/57 (7%; p=0.06). At 12 months, MACE rates were 22% in the Taxus group and 9% in the DEB group (P=0.08). The TLR at 12 months was 15% in the Taxus group and 6% in the DEB group (p=0.15). Based on these two pivotal trials, the European Society of Cardiology Guidelines for Percutaneous Coronary Intervention (2010) recommended that DEB should be considered for the treatment of in-stent restenosis after prior bare-metal stent. This was accorded a class 2 IIa indication, with a level B evidence.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects; Angioplasty, Balloon, Coronary/instrumentation*
  10. Boo YL, Liam CCK, Lim SY, Look ML
    Hong Kong Med J, 2019 Feb;25(1):74-5.
    PMID: 30713145 DOI: 10.12809/hkmj176972
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  11. Sim KH, Ong TK, Chin SP, Wong M
    Indian Heart J, 2007 Mar-Apr;59(2 Suppl B):B25-32.
    PMID: 19153433
    Matched MeSH terms: Angioplasty, Balloon, Coronary*
  12. Loch A, Bewersdorf JP, Veeriah RS
    Indian Heart J, 2017 03 17;69(5):651-654.
    PMID: 29054192 DOI: 10.1016/j.ihj.2017.03.002
    The LEADERS FREE trial concluded that the polymer free drug-coated BioFreedom™ stent appeared to be both safer and more effective than bare-metal stents (BMS) with an ISR rate comparable to traditional DES without the need for prolonged DAPT. We implanted 45 BioFreedom™ stents in 34 patients over a 4-month period. 4 patients represented early (106-238 days after the implant procedure) with angina symptoms and severe ISR was detected in all patients. The rate of severe and early ISR detected in our patient population of 11.8% is comparable to that of traditional BMS. Further studies are warranted.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/methods*
  13. Devasia T, Shetty PN, Kareem H, Karkala YR, Singh A
    Indian Heart J, 2018 Dec;70 Suppl 3(Suppl 3):S353-S358.
    PMID: 30595288 DOI: 10.1016/j.ihj.2018.10.411
    BACKGROUND: Lifestyle modification (LSM) such as prudent diet, physical activity, avoidance of smoking, and maintaining a healthy weight may considerably decrease the risk for coronary artery disease.

    OBJECTIVE: The primary objective of this study was to develop a new LSM scoring system and investigate the correlation between adherence to LSM and incidence of major adverse cardiac events (MACEs) at 12-month follow-up.

    METHOD: A total of 1000 consecutive patients who underwent percutaneous transluminal coronary angioplasty (PTCA) were included in this prospective single-center study. Manipal lifestyle modification score (MLSMS) was developed by using five lifestyle-related factors. Adherence to LSM at the baseline and subsequent follow-ups was determined by using MLSMS. The MACE at 1-, 6-, and 12-month follow-up were analyzed.

    RESULTS: There was a significant reduction in overall adherence to LSM (p 

    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects*
  14. Azarisma, S.M.S., Rosli, M.A.B.
    MyJurnal
    We report a-56-year old army pensioner who presented initially to a peripheral hospital with acute ST-elevation inferior myocardial infarction thrombolysed with streptokinase. He was subsequently referred to the National Heart Institute (Institut Jantung Negara, Malaysia) for coronary revascularization. Coronary angiogram revealed an ectatic right coronary artery with discrete lesions at the proximal and distal segments stented with bare metal stents (BMS). Post dilatation shots revealed a wire-induced, distal dissection at the posterior left ventricular artery remedied by balloon angioplasty but resulting in balloon-induced crumpling of the distal BMS. We discuss the importance of sequential, distal-to-proximal coronary intervention, stent crumpling and remedial strategies.
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  15. Chee KH, Siaw FS, Chan CG, Chong WP, Imran ZA, Haizal HK, et al.
    Int J Clin Pract, 2005 Jun;59(6):628-31.
    PMID: 15924588
    This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.
    Matched MeSH terms: Angioplasty, Balloon, Coronary*
  16. Thuraisingham S, Tan KH
    Int J Clin Pract, 1999 Dec;53(8):604-7.
    PMID: 10692754
    Direct coronary angioplasty with stent implantation is an effective treatment for acute myocardial infarction. The use of adjunctive abciximab, a platelet glycoprotein IIb/IIIa receptor antagonist is expensive. We report on three cases of direct coronary angioplasty complicated by extensive thrombus formation that were successfully treated with attenuated dosing of abciximab via the intracoronary route. All patients presented with acute myocardial infarction complicated by cardiogenic shock or eminent cardiogenic shock. Abciximab was administered after balloon dilatation when extensive thrombus formation was noted and persisted despite repeated inflations. In all three patients a single 10 mg vial of intracoronary abciximab was administered, resulting in complete dissolution of thrombus, allowing successful deployment of stents. Thus, a single 10 mg intracoronary bolus dose of abciximab may be sufficient to achieve high local concentrations of antiplatelet activity. This facilitates thrombus dissolution and allows the safe deployment of a stent to normalise intracoronary rheology.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects*
  17. Ali RM, Abdul Kader MASK, Wan Ahmad WA, Ong TK, Liew HB, Omar AF, et al.
    JACC Cardiovasc Interv, 2019 Mar 25;12(6):558-566.
    PMID: 30898253 DOI: 10.1016/j.jcin.2018.11.040
    OBJECTIVES: The aim of this randomized controlled trial was to investigate a novel sirolimus-coated balloon (SCB) compared with the best investigated paclitaxel-coated balloon (PCB).

    BACKGROUND: Treatment of coronary in-stent restenosis (ISR) remains challenging. PCBs are an established treatment option outside the United States with a Class I, Level of Evidence: A recommendation in the European guidelines. However, their efficacy is better in bare-metal stent (BMS) ISR compared with drug-eluting stent (DES) ISR.

    METHODS: Fifty patients with DES ISR were enrolled in a randomized, multicenter trial to compare a novel SCB (SeQuent SCB, 4 μg/mm2) with a clinically proven PCB (SeQuent Please Neo, 3 μg/mm2) in coronary DES ISR. The primary endpoint was angiographic late lumen loss at 6 months. Secondary endpoints included procedural success, major adverse cardiovascular events, and individual clinical endpoints such as stent thrombosis, cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis.

    RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment late lumen loss was 0.21 ± 0.54 mm in the PCB group versus 0.17 ± 0.55 mm in the SCB group (p = NS; per-protocol analysis). Clinical events up to 12 months also did not differ between the groups.

    CONCLUSIONS: This first-in-man comparison of a novel SCB with a crystalline coating shows similar angiographic outcomes in the treatment of coronary DES ISR compared with a clinically proven PCB. (Treatment of Coronary In-Stent Restenosis by a Sirolimus [Rapamycin] Coated Balloon or a Paclitaxel Coated Balloon [FIM LIMUS DCB]; NCT02996318).

    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects; Angioplasty, Balloon, Coronary/instrumentation*